Loading...
Housekeeping Pads.pdf Mar 26, 2015 Submittal Review Swedish Edmonds ACCMarch 17, 2015 Project:Date: of 1 1 Page: Andris Lapins - NBBJ Architect: Scott Solberg - SellenAdam Bettcher Contractor:Reviewed by: NO EXCEPTIONS TAKEN REJECTED MAKE CORRECTIONS NOTED SUBMIT SPECIFIED ITEMS REVISE AND RESUBMIT SUBMITTAL NOT REQUIRED & NOT REVIEWED This review is only for general conformance with the design concept of the project and general compliance with the information given in the contract documents. Corrections or comments made during this review do not relieve contractor from compliance with the requirements of the drawings and specifications and do not authorize changes to contract cost. Contractor is responsible for: Dimensions which shall be confirmed and correlated at the job site; fabrication process and techniques of construction; coordination of his work with that of all other trades; performing his work in a safe manner. Sparling has reviewed the copy of submittal 135-230548001-1 – Seismic and Vibration for Mechanical Equipment received electronically on March 3, 2015, and our comments are as follows. (Note: All of our review comments are contained in this document. There are no markups on any of the information sheets submitted.) This submittal is a revision of the previous vibration isolation submittal. Sparling requested that the submittal be revised and resubmitted due to discrepancies between the spec and the submittal for the S-3 spring isolator that was located on the chiller. Specifically, a neoprene pad needed to be inserted between the spring and the plate, along with a loading distribution mechanism. The revised submittal (Revision 3, the most recent revision from VMC) places ‘Custom MS-2E vibration isolators with integral seismic restraint with Maxi-Flex Pads for 2” deflection’ on the chillers. These pads replace the original neoprene cup of the spring with VMC “Gray” elastomeric pads set beneath a metal plate. The submittal does not appear to specify the thickness or shape of the Maxi-Flex Pads pads, which should be ¾” to 1” thick. Please submit information on this product, such as specific cutsheets, and specify the thickness. Maureen Jackson – Sparling cc hb:B17787\\SR 230548.001 4100 194th St SW • Suite 400, Lynnwood, Washington 98036-4613 206-667-0555 800-667-0610 Fax: 206-667-0554 www.sparling.com 1 | Page SUBMITTAL FOR APPROVAL Submittal #: 135 -230548.001 Rev#: 1 7039. - SWEDISH/EDMONDS-AMBULATORY CARE Priority: Medium CENTER Date: 03/02/2015 To: RACHEL JENNER From: SCOTT SOLBERG NBBJ SELLEN CONSTRUCTION CO., INC. 223 Yale Ave 227 WESTLAKE AVE N Seattle, 98109 SEATTLE, WA 98109 Originator: HERMANSON COMPANY LLP Description: Seismic for Penthouse Equipment REVISED We are transmitting the following Submittal Package item(s) for your review in accordance with the contract specifications. Please review and respond to: SCOTT SOLBERG, by: 3/16/2015. Additional Notes: Item Number Spec Section Description Details Notes 135-001.1 Pump Skids Seismic 135-002.1 Cooling Towers Seismic 135-003.1 AHU & Chiller Seismic 135-004.0 Housekeeping Pad Layout cc: 230548-001.1 Cooling Tower Seismic Resubmittal 2/26/15 Please note that Amber Booth has increased the size of the Embed Plate to 11 x 24. Also please note that as in the last Revision they are stating on Page 10- ŒNo.4 bar with stirrups suppl. reinforcement is required on curb Page # Item # X: Tags - CTWR001 Calculate the maximum loading at the most critical restraint location. MfrModelMin. limitActualMax. limit EvapcoATWB 9-7H8 Ss =1.27ap = 2.5From the tables:Fp/Wp = 0.38 g's1.898 g's2.024 g's z/h =1.0Rp = 2Fa = DLE 1.00 Site ClassCIp = 1.5S = Load Combination 11 0.844 DS 0.7 Use GroupIVCalc'd Seismic Design CategoryLoad Combination 20.6 D Input DataCalculated Values WeightHcgXcgYcgHoriz g'sVertical g'sPhxPz MaxPz Min 16130 #86.2"50.9"44.9"1.3290.4821.11821429 #18035 #7773 # Overturning Rigid Weight Seismic Vertical Restraint Locations Iy1Ix1IxyJ1 LoadsDistributionDistribution 0.00"0.00"25802019228245996831 #2685 #98348125 50.88"0.00"02019-420196851 #2692 #98618148 101.50"0.00"25712019-227945916871 #2699 #98888171 101.50"89.88"2571201922794591-6831 #2691 #-3822-5534 50.88"89.88"0201942019-6851 #2685 #-3849-5557 0.00"89.88"25802019-22824599-6871 #2678 #-3877-5580 00 00 00 00 00 00 00 00 00 00 ThetaIy totalIx totalIxy totalJ total0 #16130 #180357773 Max Reactions per Location 179.9 deg0.002 rad1030212116022419 Comp (Max Vert) 9888 # Tens. (Min Vert) 5580 # Tanr max# Vertical Restraints# Horizontal Restraints Shear 3578 # -0.00267.8"66 X: Tags - CTWR001Wind Loads Per ASCE7-10 MfrEvapcoModelATWB 9-7H8DLW 101.5"Wind Speed115 mphEquiv g's0.22Load Combination 11.2 Length 1 89.9"Mean Height54 ftExposure SummaryLoad Combination 20.9 Depth Urban/suburban, closely spaced buildings, trees 172.5"ExposureBB Height Open with scattered obstructions 16130 #qh25.9 psfC Weight Area 121.6 sq ftWind ForceDFlat, unobstructed, fields and water surfaces 3480 # Calculate the maximum loading at the most critical restraint location. XcgYcgHcgHoriz g'sVertical g'sPhPz MaxPz Min 47.8"41.5"86.3"0.2161.2000.9003480 #19356 #14517 # Restraint LocationsOverturning StaticWind Distribution Iy1Ix1IxyJ1 Loads1.0 g Vert XYMax VertMin Vert 0.00"0.00"25802019228245991113 #3132 #4871 #3932 # 50.88"0.00"02019-420191113 #2894 #4585 #3717 # 101.50"0.00"25712019-227945911113 #2656 #4301 #3504 # 101.50"89.88"2571201922794591-1113 #2245 #1581 #908 # 50.88"89.88"0201942019-1113 #2482 #1866 #1121 # 0.00"89.88"25802019-22824599-1113 #2721 #2152 #1335 # CxCyIy totalIx totalIxy totalJ total0 #16130 #19356 #14517 # 50.8"44.9"1030212116022419Comp (Max Vert) 4871 # Maximum Center of Restraints# Vertical Restraints# Horizontal RestraintsTens. (Min Vert) 0 # Reactions 50.8"44.9"66Shear 580 # Profis Anchor 2.5.0 www.hilti.us Company:The VMC GroupPage:12 Specifier:Project:Swedish Edmonds ACC Address:11930 Brittmoore Park Drive, Houston, TX 77041Sub-Project I Pos. No.:CTWR001 Phone I Fax:713-466-0003 | 713-466-1355Date:2/5/2015 E-Mail: Specifier's comments: 1 Input data Anchor type and diameter: AWS D1.1 GR. B 7/8 Effective embedment depth: h = 6.500 in. ef Material: Proof: Design method ACI 318-08 / CIP Stand-off installation: e = 0.000 in. (no stand-off); t = 0.750 in. b Anchor plate: l x l x t = 24.000 in. x 9.000 in. x 0.750 in.; (Recommended plate thickness: not calculated) xy Profile: no profile Base material: cracked concrete, 3000, f' = 3000 psi; h = 20.000 in. c Reinforcement: tension: condition B, shear: condition B; edge reinforcement: > No. 4 bar with stirrups Seismic loads (cat. C, D, E, or F) yes (D.3.3.5) Geometry \[in.\] & Loading \[lb, in.lb\] Input data and results must be checked for agreement with the existing conditions and for plausibility! PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan Profis Anchor 2.5.0 www.hilti.us Company:The VMC GroupPage:13 Specifier:Project:Swedish Edmonds ACC Address:11930 Brittmoore Park Drive, Houston, TX 77041Sub-Project I Pos. No.:CTWR001 Phone I Fax:713-466-0003 | 713-466-1355Date:2/5/2015 E-Mail: 2 Proof I Utilization (Governing Cases) Design values \[lb\]Utilization LoadingProofLoadCapacity / \[%\]Status aaaaaaaa NV Tension Concrete Breakout Strength55801214446 / -OK Shear Concrete edge failure in direction x+35784346- / 83OK LoadingStatus Utilization \[%\] aaaaaaaayyyyaaaa NVN,V Combined tension and shear loads0.4600.8235/3100OK 3 Warnings • Please consider all details and hints/warnings given in the detailed report! Fastening meets the design criteria! 4 Remarks; Your Cooperation Duties • Any and all information and data contained in the Software concern solely the use of Hilti products and are based on the principles, formulas and security regulations in accordance with Hilti's technical directions and operating, mounting and assembly instructions, etc., that must be strictly complied with by the user. All figures contained therein are average figures, and therefore use-specific tests are to be conducted prior to using the relevant Hilti product. The results of the calculations carried out by means of the Software are based essentially on the data you put in. Therefore, you bear the sole responsibility for the absence of errors, the completeness and the relevance of the data to be put in by you. Moreover, you bear sole responsibility for having the results of the calculation checked and cleared by an expert, particularly with regard to compliance with applicable norms and permits, prior to using them for your specific facility. The Software serves only as an aid to interpret norms and permits without any guarantee as to the absence of errors, the correctness and the relevance of the results or suitability for a specific application. • You must take all necessary and reasonable steps to prevent or limit damage caused by the Software. In particular, you must arrange for the regular backup of programs and data and, if applicable, carry out the updates of the Software offered by Hilti on a regular basis. If you do not use the AutoUpdate function of the Software, you must ensure that you are using the current and thus up-to-date version of the Software in each case by carrying out manual updates via the Hilti Website. Hilti will not be liable for consequences, such as the recovery of lost or damaged data or programs, arising from a culpable breach of duty by you. Input data and results must be checked for agreement with the existing conditions and for plausibility! PROFIS Anchor ( c ) 2003-2009 Hilti AG, FL-9494 Schaan Hilti is a registered Trademark of Hilti AG, Schaan WHOBYTHEUSEHEREOFACKNOWLEDGETHEVMCGROUP'SOWNERSHIPANDAGREETOMAINTAINTHISINFORMATIONANDDESIGNINSTRICTCONFIDENCE.PROPRIETARY:EXCEPTASOTHERWISEAGREEDINWRITING,THEINFORMATIONANDDESIGNDISCLOSEDHEREINARETH EPROPERTYOFTHEVMCGROUPANDMUSTNOTBECOPIEDORDISTRIBUTEDOUTSIDETHEVMCGROUPEXCEPTTOAUTHORIZEDPERSONSWITHAGENUINENEEDTOKNOW CERTIFIEDFOR: SALESORDER:CUSTOMERP.O.:CUSTOMER:JOBNAME: 1.STANDARDISOLATORFINISH:CASTINGANDWELDMENTS-ONECOATBLACKPAINT, NOTES: 3.STATICLOADRATINGSONSHEET2OF2AREFORGUIDANCEONLY.VALUESAREBASEDONTESTSOR2.ESTIMATEDUNITWEIGHT:130LBS. FACTORY. CALCULATIONSWITHBASEPLATESBOLTEDTOSTEEL.FORATTACHMENTTOCONCRETE,CONSULTOPERATING SPRINGS-POWDERCOAT,HARDWARE-ZINCELECTROPLATE. FREEAND HEIGHT 103/8 (3/4)9 1 SWEDISH EDMONDS ACC 7 GAP 1 1/4 43/4 5/8-11UNCTAPPED HOLE(4TYP) 71/2 1719 21 ELASTOMERICCUP 1ADJUSTINGBOLT VIBRATIONISOLATORS SEISMICRESTRAINT FORCLARITY)INTOPVIEW (NOTSHOWN 3/4LIMITSTOP MODELM2SH-2F 2"DEFLECTION (3/4) 1/4 13/4 21/2 11/2 6 13/16DIAHOLEFOR CONCRETE(6TYP) ATTACHMENTTO 1.TWONESTEDSPRINGSYIELDTHISLOAD.THECOLORCODEINDICATEDISFOROUTERSPRING/INNERSPRING.NOTES: M2SH-2F-4400NM2SH-2F-3800NM2SH-2F-3350NM2SH-2F-3000NM2SH-2F-2800M2SH-2F-2550NM2SH-2F-2300NM2SH-2F-2000M2SH-2F-1550NM2SH-2F-1300NM2SH-2F-1000M2SH-2F-850NM2SH-2F-550M2SH-2F-300 NOTE:MATERIALSHOWNISFOR(1)SET. LOC7:LOC5:LOC3:LOC1: CUSTOMEREQP'T.TAG: MODELM2SH-2F2-SPRINGSEISMICISOLATORSFORNOMINAL2"DEFLECTION MODEL 1 11111111 21 THEVMCGROUP RATEDLOAD Bloomingdale,NJ07403 ThePowerofTogether Houston,TX77041 (LBS) 44003800335030002800255023002000155013001000 850550300 ISOLATORSELECTIONS PROPERTIESMAYBESUBSTITUTEDASTHEYBECOMEAVAILABLE. OTHERMATERIALS,COMPOUNDS,ORFINISHESWITHEQUALORSUPERIOR 3 4 DEFLECTION RATED 2.002.002.002.002.002.002.002.002.002.002.002.002.002.00 (IN) LOC8:LOC6:LOC4:LOC2: DRAWINGNO.: SHEET:SCALE: SPRINGRATE 1OF2 6 5 (LB/IN) NONE 22001900167515001400127511501000 775650500425275150 GRAY/GREENGRAY/REDGRAY/BLACKGREEN/REDGRAYGREEN/BLACKGREEN/BLUEGREENRED/BLACKRED/BLUEREDBLACK/BLUEBLACKBLUE COLORCODE 87 SPRING REVISION WHOBYTHEUSEHEREOFACKNOWLEDGETHEVMCGROUP'SOWNERSHIPANDAGREETOMAINTAINTHISINFORMATIONANDDESIGNINSTRICTCONFIDENCE.PROPRIETARY:EXCEPTASOTHERWISEAGREEDINWRITING,THEINFORMATIONANDDESIGNDISCLOSEDHEREINARETH EPROPERTYOFTHEVMCGROUPANDMUSTNOTBECOPIEDORDISTRIBUTEDOUTSIDETHEVMCGROUPEXCEPTTOAUTHORIZEDPERSONSWITHAGENUINENEEDTOKNOW CERTIFIEDFOR: SALESORDER:CUSTOMERP.O.:CUSTOMER:JOBNAME: 10.ADJUSTMENTISCOMPLETE.1.ISOLATORSARESHIPPEDFULLYASSEMBLEDANDARETOBESPACEDANDLOCATEDINACCORDANCE INSTALLATIONANDADJUSTMENTINSTRUCTIONS 9.ADJUSTALLLIMITSTOPNUTSTOOBTAINA1/4"MAXIMUMCLEARANCE.8.CHECKEQUIPMENTLEVELANDFINEADJUSTISOLATORSASNECESSARYTOOBTAINEQUIPMENTLEVEL.7.ADJUSTEACHANDEVERYISOLATORINSEQUENCE,ONEFULLCLOCKWISETURNATATIME.R EPEAT6.BACK-OFFONTHETWO(2)SIDELIMITSTOPLOCKNUTS,SOTHATTHEYDONOTHAMPERTHE5.THEEQUIPMENTWEIGHTWILLCAUSETHESPRINGANDTHUSTHETOPPLATETODESCENDANDRESTON3.ANCHORALLISOLATORSTOTHEFLOORORSUB-BASEASRECOMMENDED .2.LOCATEISOLATORSONALEVELFLOORORSUB-BASE,ENSURINGTHATALLISOLATORCENTERLINES 4.GENTLYPLACEMACHINEOREQUIPMENTONTOTOPPLATEOFISOLATORBOLTEQUIPMENTORSUBBASE 1.TOUSETHERATEDLOADCURVES: RATEDLOADCURVES 3.THERATEDLOADCURVESASSUMEONEOFTHEFOLLOWINGMETHODSOFTIE-DOWNATEACHBOLT 4.THESUPPORTSTRUCTURE(BYOTHERS)ISTHERESPONSIBILITYOFTHEARCHITECTORENGINEER NUTSCONTINUETOSHOWCLEARANCE.BASEPLATES.A1/4"MAXIMUMDIFFERENCEINELEVATIONCANBETOLERATED.MATCHTHEEQUIPMENTMOUNTINGHOLES.SHIMORGROUTASREQUIREDTOLEVELALLISOLATOR THISPROCEDUREUNTILTHE1/4"OPERATINGCLEARANCEISOBTAINED.NOTE:BESURELIMITSTOPTHEUPPERBUMPERPADS.SHOULDNOTPROTRUDEMORETHAN1/8"BELOWTHETOPPLATE.SECURELYTOISOLATORUSINGMINIMUMASTMA325(SAEGR.5)HIGHSTRENGTHB OLTS.BOLTS ADJUSTMENTPROCESS.WITHINSTALLATIONDRAWINGSORASOTHERWISERECOMMENDED. B.FOUR(4)3/4"DIA.BOLTSPERASTMA307ORBETTER.LOCATION:B.THEINTERSECTIONOFTHEHORIZONTALLOADANDVERTICALLOADMUSTFALLWITHINTHECURVE OFRECORDANDSHALLBEDESIGNEDTOADEQUATELYSUPPORTTHEWEIGHTSANDFORCESSHOWN.A.FOUR(4)3/4"DIA.HILTI"KWIK-BOLTII"WEDGEANCHORS,WITHMINIMUM43/4"EMBEDMENTINTOA.CALCULATEVERTICALANDHORIZONTALFORCESACTINGONMOUNTI NGS,INCLUDING INSTALLATIONS,ASDESCRIBEDBELOW: REPORT).BOLTSMAYBEUSED,PROVIDEDTHEYAREOFEQUALSTRENGTHANDHAVEACURRENTICBOFORTHESPECIFIEDPART. c)IFANYANCHORFAILSTESTING,TESTALLANCHORSUNTILTWENTY(20)CONSECUTIVEANCHORSb)TESTINGSHOULDOCCUR24HOURSMINIMUMAFTERINSTALLATIONOFANCHORS.a)50%ORALTERNATEBOLTSINAGROUPSHALLBETENSIONTESTEDTO6200LBSTENSION .3000PSICONCRETE.MINIMUMEDGEDISTANCEIS93/4".(NOTE:OTHERBRANDSOFANCHOR TOACHIEVERATEDLOAD,"SPECIALINSPECTION"ISREQUIREDONALLCONCRETEANCHORTRANSLATIONSANDOVERTURNINGMOMENTS. PASS,THENRESUMETHEINITIALTESTINGFREQUENCY. SWEDISH EDMONDS ACC VIBRATIONISOLATORS SEISMICRESTRAINT MODELM2SH-2F 2"DEFLECTION VERTICALLOAD 100001100012000130001400015000160001700018000190002000021000 100020003000400050006000700080009000 0 0 1000 2000 THEVMCGROUP Bloomingdale,NJ07403 ThePowerofTogether Houston,TX77041 3000 (ATTACHMENTTOSTEEL) 4000 VERTICALLOAD(THOUSANDPOUNDS) PROPERTIESMAYBESUBSTITUTEDASTHEYBECOMEAVAILABLE. OTHERMATERIALS,COMPOUNDS,ORFINISHESWITHEQUALORSUPERIOR SEISMICRATINGS 2022 1012141618 2468 HORIZONTALLOAD 5000 FIGURE2 (ATTACHMENTTOCONCRETE) 2 6000 HORIZONTALLOAD(THOUSANDPOUNDS) 4 SEISMICRATINGS DRAWINGNO.: SHEET:SCALE: FIGURE1 6 7000 2OF2 NONE 8 8000 12000POUNDS 10 9000 12 14 10000 16 11000 REVISION