Loading...
IncompleteLetter.pdfInC �Si�O August 14, 2007 Troy Renneke TNT, LLC 1136 Vista Place Edmonds WA 98020 CITY OF EDMONDS 121 5TH AVENUE NORTH • EDMONDS, WA 98020 • (425} 771-0220 - FAX (425) 771-0221 Website: www.ci.edmonds.wa.us DEVELOPMENT SERVICES DEPARTMENT Planning • Building • Engineering Leah White Alpha Subdivision Pro's Inc. 4727-A Evergreen Way Everett WA 98203 GARY HAAKENSON MAYOR SUBJECT: ARCHITECTURAL DESIGN BOARD (ADB) APPLICATION (ADB -2007-60). Dear Applicant: You have submitted an application for design review by the Architectural Design. Board (ADB) for the property at 8629 238" Street SW, which is located in the Multiple Residential (RM -1.5) zone. Today, City staff determined that the application was INCOMPLETE. Please submit the following items so we can continue to review your application. The following items are necessary for "completeness." In addition to the following items, I have also requested some additional information to help you better support your proposal. Please respond to these items as well. Please provide the following item in order to submit a "complete" apalication: I. Notarized APO Declaration: Please submit the required notarized Adjacent Property Owner (APO) List Declaration, which certifies that the names and addresses provided represent all properties located within 300 feet of the subject property. I've enclosed another copy for your convenience. 2. Engineering Memo: I've enclosed a memo from the Engineering Division (Engineering Program Manager Jeanie McConnell). Please submit a response to her questions, through me, at your earliest convenience. I've enclosed the Traffic Impact Analysis handout she's referenced, for your convenience. Please provide the following additional information to better support your proposal: 1. Land Use Application: a. Who has signed for the owner/applicant? Please confirm that this is Troy Renneke. L Do you have a preferred name for this project? This line was lett blank, but I'll use "TNT Duplex & Triplex" unless I hear otherwise. 2. Elevations: Height is not shown on the elevations. Although it is not required at this point in review, please know that the maximum height in the RM -L5 zone is 25 feet (with an exception for a 5 foot bonus if all of the roof between 25-30 feet is at a4/1[2 pitch or greater). Height is always measured from average original grade. If you have already completed your height calculations, please submit them so the ADB can be assured that your project is planned to remain under the height limit. Or, please submit a statement on the project's estimated height. I'd be happy to explain this further. 3. SEPA Checklist: The SEPA Checklist indicates 900 cubic yards of material to be removed. How much fill is proposed, if any? Page 1 of 2 • Incorporated August 11, 1890 • Sister Cita - Hekinan..Iar)an 4. Site Plan: a. Is the fence to remain or to be removed? Please note. b. Is the shed to remain or to be removed? Please note. c. There are two monument signs shown — are they existing or proposed? If they are proposed, what is the estimated height? Do you have a preliminary design for the ADB to review? If they are existing, are they to remain? d. The site plan shows many existing large mature evergreens — which are to remain and which are to be removed? Please coordinate this information with the Landscape Plan. 5. Landscape Plan: a. Are any of the existing trees to remain? Which ones? Please note. b. Do you have a report by an ISA certified arborist that would justify the removal of large mature evergreens around the perimeter of the site? It is not a requirement, but if you have one it may help the ADB understand why you wish to remove these trees (if that is indeed what you propose). 6. Townhouse Subdivision: Do you intend to further subdivide the property through the "Townhouse Subdivision" process? If so, it's handy to know this up front so that I can put you in touch with the appropriate people in City Hall. Please note the following definition of Townhouse to ensure that your project would qualify for this process: ECDC 21.100.040 Townhouse. Townhouse means a multiple dwelling unit meeting the following criteria: A. No dwelling unit overlapping another vertically; B. Common side walls joining units; C. Not more than six dwelling units in one structure; D. Coverage shall not exceed the aggregate coverage ofthe individual structures as defined in the zoning code, E. Lot area per unit for purposes of subdivision may be as small as the coverage of the individual unit, so long as the overall density meets the zoning on the site. Portions of the site not subdivided for individual units shall be held in common by the owners of the individual units. 7. Fire Department Memo: I've enclosed a memo from the Fire Department (Fire Marshal John Westfali). Please submit a response to his questions, through me, at your earliest convenience. If staff finds that additional information is needed; we will notify you in writing that additional information is needed. While this information -request is pending, the 120 -day clock for processing the application will stop running. When the additional information is submitted, staff will review it to insure that it responds fully to the information request. When the request for additional information has been satisfied, the 120 -day clock will start running again. I am the Planner assigned to work on your application. If you have further questions, please do not hesitate to contact me at 425.771.0220, extension 1778. Thank you for your interest in development in the City of Edmonds — I look forward to working with you on this project Sincerely, Gina Caccia Planner CC7 File ADS -2007-60 Page 2 of 2 ADJACENT PROPERTY OWNERS LIST Attach this notarized declaration to the adjacent property owners list. On my oath, I certify that the names and addresses provided represent all properties located within 300 feet of the subject property. Signature of Applicant or Applicant's Representative Subscribed and sworn to before me this day of , Notary Public in and for the State of Washington Residing at APO.DOC Y MEMORANDUM Date: July 25, 2007 To: Gina Coccia, Planner 0 From: Jeanie McConnell, Engineering Program Manager Subject: PLN20070060 (ADB) — TNT, LLC — 8629 238t" St SW Duplex & Triplex Engineering has reviewed the subject application and provides the following comments. Please provide a traffic impact analysis worksheet and determine impact fees based on Edmonds Community Development Code 18.82. Please refer to public handout 4E82 Traffic Impact Analysis Requirements available on the City website at www.ci.edmonds.wa.us The Traffic Impact Analysis will be reviewed by Bertrand Hauss, Traffic Engineer upon resubmittal. The storm drainage system for this development will need to be designed and stamped by a licensed engineer as the imperious surface area exceeds 5000 square feet. The stormwater management memorandum submitted with this application accounts for a "credit" of existing impervious areas. With the redevelopment of this property there will not be a credit given for any existing impervious areas. Storm system design and calcs will be reviewed at the time of building permit submittal. Thank you. City of Edmonds • MEMORANDUM August g, 2007 Planner Gina Coccia Fire Marshal John J. Westfall 425.771.0213 , PLN20070060 TNT LLC 1 Renneke Condos 8629 238'x' St SW The following plans have been evaluated under the 2003 International Codes and Edmonds Community Development Code. Architectural information is limited on the project submittal for affirmative review. Accommodating fire access and fire protection requirements may impact final site design for Architectural Design Board review. 1 } Site plan indicates RS -8 zoning yet (current) COE zoning 616107 map indicates RM1.5. Clarify and indicate correct zoning. 2) A single fire hydrant is indicated across 238th. Fire hydrants require 300' spacing in RM zones; 600' in RS zones. Clearly show available hydrants on site plan with correct hydrant spacing. 3) Townhouse dwellings as defined by International Residential Code (IRC) are treated as separate dwellings. Three-plexes constructed as specified by International Building Code (IBC) shall be fire sprinklered and may impact site design. Clearly indicate townhouse construction in accordance with IRC that is consistent with water services indicated on C3.1. Cc: Ms. Leah White ASPI, leah(a).alphasub.com Engineering Technician Jeanie McConnell City of Edmonds a Fire Marshal