Inspection Correction Notice. 11.4.19.pdfOF ED41
O
Est. I S90
CITY OF EDMONDS
CORRECTION NOTICE
ENGINEERING DIVISION
(425) 771-0220
City Website: www.edmondswa.gov
DATE: November 4, 2019 PERMIT NUMBER: ENG20190069
OWNER: John Zimmerman SITE CONTACT: Greg Brewer
ADDRESS: 820 Dayton St
TYPE OF INSPECTION: Curb and Gutter Pre -Pour
❑ WORK DESCRIBED BELOW HAS BEEN INSPECTED AND APPROVED
❑ APPROVED PLANS AND PERMIT JOB CARD MUST BE AVAILABLE TO INSPECTOR
ON SITE
® CORRECTIONS LISTED BELOW MUST BE MADE BEFORE WORK CAN BE
APPROVED AND/OR THE NEXT PHASE OF WORK IS STARTED.
® RECALL FOR INSPECTION
❑ REINSPECTION FEE MUST BE PAID PRIOR TO NEXT INSPECTION REQUEST.
❑ STOP WORK UNTIL AUTHORIZED TO CONTINUE BY CITY INSPECTOR
1. Install form on the backside of the curb as per City of Edmonds standard detail TR-521.
2. Curb must be 8 '/a" at the base and 16" tall where it meets existing curb as per City of Edmonds
standard detail TR-521.
3. Form a'/2" lip for the driveway approach.
4. Install2" of 5/8 minus crushed rock and compact to 95% in all areas where asphalt roadway has
been removed.
5. Call for form inspection prior to scheduling concrete.
For inspection scheduling call 425-771-0220 x1326.