CITY OF EDMONDS
CORRECTION NOTICE
ENGINEERING DIVISION
(425) 771-0220
City Website: www.edmondswa.gov
DATE: August 11, 2016 PERMIT NUMBER: BLD20150520
OWNER: Merloine Geier Properties SITE CONTACT: Mick Weber
ASSOCIATED PERMITS:
ADDRESS: 21940 Highway 99 Right of Way, Side Sewer
TYPE OF INSPECTION:
FINAL INSPECTION
WORK DESCRIBED BELOW HAS BEEN INSPECTED AND APPROVED
APPROVED PLANS AND PERMIT JOB CARD MUST BE AVAILABLE TO INSPECTOR ON
SITE
CORRECTIONS LISTED BELOW MUST BE MADE BEFORE WORK CAN BE APPROVED.
RECALL FOR INSPECTION
REINSPECTION FEE MUST BE PAID PRIOR TO NEXT INSPECTION REQUEST.
STOP WORK UNTIL AUTHORIZED TO CONTINUE BY CITY INSPECTOR
th
1.Provide Compaction Testing results for the sewer trench on 220 St SW.
2.Install 12” cast iron lamphole lid with ½” hexbolts on sewer clean out at property line.
3.Clean up material at base of Fire Hydrant.
4.Detention Manhole first step shall be installed in top pick holes.
5.Mud rim for east catch basin.
6.All stormwater structures shall be cleaned.
7.Install solid lids on the existing catch basins adjacent to the each of the new filter systems.
8.Clear asphalt or concrete from edges of all utility covers to ensure easy access.
9.Provide asbuilts. One hard copy and an electronic copy.
10.Curb Ramp does not meet ADA Specifications. Approved plan states that City of Edmonds
Curb Ramp Type 5 shall be installed. See attached plans and field notes. Remove and replace
panels as needed to meet requirements. WSDOT Standard Plan F-40.12-03 Parallel Curb Ramp
Type A is the equal to the City’s Type 5. *
*The City is willing to final the commercial construction when #1 through #7 are completed and
approved allowing the curb ramp replacement to be completed with the short plat curb ramp
replacements. The commercial construction bond will be held until the curb ramp is replaced and
approved.
For inspection scheduling call 425-771-0220 x1326.