Loading...
INSPECTION ITEMS.pdf'tic. I S4 Construction Progress Card City of Edmonds 121 5th Ave N Edmonds WA 98020 To schedule your inspections: B - building: 1. Go to: www.edmondswa.gov 2. Then: Services 3. Then: Permits/Development 4. Then: Online Permit Info 5: If you don't have one already, create a login (upper right hand corner) 6: Schedule your inspection E - engineering: 425.771.0220 ext. 1326 F - fire: 425.775.7720 P - planning: 425.771.0220 B - building front desk during office hours: 425.771.0220 Call 24 hours in advance for inspections Scope of work: COMPLIANCE PERMIT FOR FAMILY HOME CHILD Permit #: BLD20190768 CARE Project Address: 18928 80TH AVE W, EDMONDS Parcel #: 00481600100700 Owner: ERIN MICHELLE/HOFF WILLIA Contractor: N/A RANCE 18928 80TH AVE W LICENSE #: EXP: EDMONDS, WA 98026 Construction hours are lam - 6pm on weekdays, loam - 6pm Saturdays. INSI'ECHON INSPlXTOR DATE C NINIF1'I'S B-Building Final �t2 l fJA�-� If�r� c�21\.1 �i t�i 1� R ev V e GTt l� ?90v l U)6 ( gS.POC n o it 2015 INTERNATIONAL RESIDENTIAL CODE T"2.0Iq-- 07%' R325.8.4.2 Horizontal grab bars. Horizontal grab bars shall be provided at the control end, head end, and the back wall within the bathtub area. Grab bars shall be mounted between 33 inches and 36 inches above floor grade. Control end and head end grab bars shall be 24 inches minimum in length. Back wall grab bar shall be 36 inches minimum in length. R325.8.5 Grab bars at shower stalls. Where shower stalls are provided to meet the requirements for bathing facilities, grab bars shall meet the requirements Of R325.8. Exception: Shower stalls with permanent built-in seats are not required to have vertical or horizontal grab bars at the seat end wall. A vertical floor to ceiling grab bar shall be installed within 4 inches of the exterior of the shower aligned with the nose of the built-in seat. R325.8.5.1 Vertical grab bars. Vertical grab bars shall be 18 inches minimum in length and installed at the control end wall and head end wall. Vertical bars shall be mounted within 4 inches of the exterior of the shower stall or within 4 inches inside the shower stall. The bottom end of vertical bars mount between 36 inches and 42 inches above floor grade. R325.8.5.2 Horizontal grab bars. Horizontal grab bars shall be installed on all sides of the shower stall mounted between 33 inches and 36 inches above the floor grade. Horizontal grab bars shall be a maximum of 6 inches from adjacent walls. Horizontal grab bars shall not interfere with shower control valves. R325.9 Ramps. All interior and exterior ramps, when provided, shall be constructed in accordance with Section R311.8 with a maximum slope of 1 vertical to 12 horizontal. The exception to R311.8.1 is not allowed for adult family homes. Handrails shall be installed in accordance with R325.9.1. R325.9.1 Handrails for ramps. Handrails shall be installed on both sides of ramps between the slope of 1 vertical to 12 horizontal and 1 vertical and 20 horizontal in accordance with R311.8.3.1 through R311.8.3.3. R325.10 Stair treads and risers. Stair treads and risers shall be constructed in accordance with R311.7.5. Handrails shall be installed in accordance with R325.10.1. R325.10.1 Handrails for treads and risers. Handrails shall be installed on both sides of treads and risers numbering from one riser to multiple risers. Handrails shall be installed in accordance with R311.7.8.1 through R311.7.8.4. 7.7 y R325.11 Shower stalls. Where provided to meet the requirements for bathing facilities, the minimum size of shower stalls for an adult family home shall be 30 inches deep by 48 inches long. SECTION R326 FAMILY HOME CHILL? CARE R326 Family home child care. For family home child care with more than six children, each floor level used for family child care purposes shall. be served by two remote means of egress. Exterior exit doors shall be operable from the inside without the use of keys or any special knowledge or effort. Basements located more than 4 feet below grade level shall not be used for family home child care homes unles n_ne nffnllowinQ conditions exist: 1. Stairways from the basement open directly to the exterior of the building without entering the first floor; or 2. One of the two required means of egress discharges directly to the exterior from the basement level, and a self -closing door is installed at the top or bottom of the interior stair leading to the floor above; or 3. One of the two required means of egress is an operable window or door, approved for emergency escape or rescue, that opens directly to a public street, public alley, yard or exit court; or 4. A residential sprinkler system is provided throughout the entire building in accordance with NFPA 13D. Floors located more than 4 feet above grade level shall not be occupied by children in family home child care. Exceptions: 1. Use of toilet facilities while under supervision of an adult staff person. 2. Family home child care may be allowed on the second story if one of the following conditions exists: 2.1. Stairways from the second story open directly to the exterior of the building without entering the first floor; or 2.2. One of the two required means of egress discharges directly to the exterior from the second story level, and a self closing door is installed at the top or bottom of the interior stair leading to the floor below; or 2.3. A residential sprinkler system is provided throughout the entire building in accordance with NFPA 13D. Every sleeping or napping room in a family home child care shall have at least one operable window for emergency rescue. Exception: Sleeping or napping rooms having doors leading to two separate means of egress, or a door leading directly to the exterior of the building. Rooms or spaces containing a commercial -type cooking kitchen, boiler, maintenance shop, janitor closet, laundry, woodworking shop, flammable or combustible storage, or (Insert as Page 77b) painting operation shall be separated from the family home child care area by at least one -hour fire -resistive construction. Exception: A fire -resistive separation shall not be required where the food preparation kitchen contains only a domestic cooking range and the preparation of food does not result in the production of smoke or grease laden vapors. SECTION R327 PROTECTION AGAINST RADON R327.1 Protection against radon. The radon control provisions of Appendix F of this code shall apply to buildings constructed in High Radon Potential Counties (zone 1) designated in Table AF 101(1). The radon control provisions of Appendix F of this code shall also apply to all buildings constructed using the provisions of Section R408.3, Unvented crawl space compliance method. WASHINGTON STATE AMENDMENTS (insert as Page Tic)