INSPECTION ITEMS.pdf'tic. I S4
Construction Progress Card
City of Edmonds 121 5th Ave N Edmonds WA 98020
To schedule your inspections:
B - building:
1. Go to: www.edmondswa.gov
2. Then: Services
3. Then: Permits/Development
4. Then: Online Permit Info
5: If you don't have one already, create a
login (upper right hand corner)
6: Schedule your inspection
E - engineering: 425.771.0220 ext. 1326
F - fire: 425.775.7720
P - planning: 425.771.0220
B - building front desk during office
hours: 425.771.0220
Call 24 hours in advance for inspections
Scope of work: COMPLIANCE PERMIT FOR FAMILY HOME CHILD
Permit #: BLD20190768
CARE
Project Address: 18928 80TH AVE W, EDMONDS
Parcel #: 00481600100700
Owner: ERIN MICHELLE/HOFF WILLIA
Contractor: N/A
RANCE
18928 80TH AVE W
LICENSE #: EXP:
EDMONDS, WA 98026
Construction hours are lam - 6pm on weekdays, loam - 6pm Saturdays.
INSI'ECHON INSPlXTOR DATE C NINIF1'I'S
B-Building Final
�t2 l fJA�-� If�r� c�21\.1 �i t�i 1� R ev V e GTt l�
?90v l U)6 ( gS.POC n o it
2015 INTERNATIONAL RESIDENTIAL CODE T"2.0Iq-- 07%'
R325.8.4.2 Horizontal grab bars. Horizontal grab
bars shall be provided at the control end, head end, and
the back wall within the bathtub area. Grab bars shall
be mounted between 33 inches and 36 inches above
floor grade. Control end and head end grab bars shall
be 24 inches minimum in length. Back wall grab bar
shall be 36 inches minimum in length.
R325.8.5 Grab bars at shower stalls. Where shower
stalls are provided to meet the requirements for bathing
facilities, grab bars shall meet the requirements Of
R325.8.
Exception: Shower stalls with permanent built-in seats
are not required to have vertical or horizontal grab bars
at the seat end wall. A vertical floor to ceiling grab bar
shall be installed within 4 inches of the exterior of the
shower aligned with the nose of the built-in seat.
R325.8.5.1 Vertical grab bars. Vertical grab bars
shall be 18 inches minimum in length and installed at
the control end wall and head end wall. Vertical bars
shall be mounted within 4 inches of the exterior of the
shower stall or within 4 inches inside the shower stall.
The bottom end of vertical bars mount between 36
inches and 42 inches above floor grade.
R325.8.5.2 Horizontal grab bars. Horizontal grab
bars shall be installed on all sides of the shower stall
mounted between 33 inches and 36 inches above the
floor grade. Horizontal grab bars shall be a maximum
of 6 inches from adjacent walls. Horizontal grab bars
shall not interfere with shower control valves.
R325.9 Ramps. All interior and exterior ramps, when
provided, shall be constructed in accordance with Section
R311.8 with a maximum slope of 1 vertical to 12
horizontal. The exception to R311.8.1 is not allowed for
adult family homes. Handrails shall be installed in
accordance with R325.9.1.
R325.9.1 Handrails for ramps. Handrails shall be
installed on both sides of ramps between the slope of 1
vertical to 12 horizontal and 1 vertical and 20 horizontal
in accordance with R311.8.3.1 through R311.8.3.3.
R325.10 Stair treads and risers. Stair treads and risers
shall be constructed in accordance with R311.7.5. Handrails
shall be installed in accordance with R325.10.1.
R325.10.1 Handrails for treads and risers. Handrails
shall be installed on both sides of treads and risers
numbering from one riser to multiple risers. Handrails
shall be installed in accordance with R311.7.8.1 through
R311.7.8.4. 7.7
y
R325.11 Shower stalls. Where provided to meet the
requirements for bathing facilities, the minimum size of
shower stalls for an adult family home shall be 30 inches
deep by 48 inches long.
SECTION R326
FAMILY HOME CHILL? CARE
R326 Family home child care. For family home child care
with more than six children, each floor level used for family
child care purposes shall. be served by two remote means of
egress. Exterior exit doors shall be operable from the inside
without the use of keys or any special knowledge or effort.
Basements located more than 4 feet below grade level
shall not be used for family home child care homes unles
n_ne nffnllowinQ conditions exist:
1. Stairways from the basement open directly to the
exterior of the building without entering the first
floor; or
2. One of the two required means of egress discharges
directly to the exterior from the basement level, and
a self -closing door is installed at the top or bottom of
the interior stair leading to the floor above; or
3. One of the two required means of egress is an
operable window or door, approved for emergency
escape or rescue, that opens directly to a public
street, public alley, yard or exit court; or
4. A residential sprinkler system is provided throughout
the entire building in accordance with NFPA 13D.
Floors located more than 4 feet above grade level shall not
be occupied by children in family home child care.
Exceptions:
1. Use of toilet facilities while under supervision of
an adult staff person.
2. Family home child care may be allowed on the
second story if one of the following conditions
exists:
2.1. Stairways from the second story open
directly to the exterior of the building
without entering the first floor; or
2.2. One of the two required means of egress
discharges directly to the exterior from the
second story level, and a self closing door is
installed at the top or bottom of the interior
stair leading to the floor below; or
2.3. A residential sprinkler system is provided
throughout the entire building in accordance
with NFPA 13D.
Every sleeping or napping room in a family home child care
shall have at least one operable window for emergency
rescue.
Exception: Sleeping or napping rooms having doors
leading to two separate means of egress, or a door
leading directly to the exterior of the building.
Rooms or spaces containing a commercial -type cooking
kitchen, boiler, maintenance shop, janitor closet, laundry,
woodworking shop, flammable or combustible storage, or
(Insert as Page 77b)
painting operation shall be separated from the family home
child care area by at least one -hour fire -resistive
construction.
Exception: A fire -resistive separation shall not be
required where the food preparation kitchen contains only
a domestic cooking range and the preparation of food
does not result in the production of smoke or grease laden
vapors.
SECTION R327
PROTECTION AGAINST RADON
R327.1 Protection against radon. The radon control
provisions of Appendix F of this code shall apply to
buildings constructed in High Radon Potential Counties
(zone 1) designated in Table AF 101(1). The radon control
provisions of Appendix F of this code shall also apply to all
buildings constructed using the provisions of Section
R408.3, Unvented crawl space compliance method.
WASHINGTON STATE AMENDMENTS
(insert as Page Tic)