Issued ROW Permit ENG20190090.pdf°r LD^'0
CITY OF EDMONDS
121 5TH AVENUE NORTH -EDMONDS, WA 98020
PHONE: (425) 771-0220 - FAX: (425) 771-0221
*PERMIT MUST BE POSTED ON JOBSITE*
STATUS: ISSUED ENG20190090
RIGHT OF WAY PERM tT (6-EtJQ
Permit Number: ENG20190090 Expiration Date: 11/21/2019
Job Address: 7416 212TH ST SW, EDMONDS Location: 7416 212th St SW
COMCAST Cablecom LLC
GO JOURDEN LAWRENCE 1316 Bonneville Ave
1525 75TH ST SW Bldg A
EVERETT, WA 98203 Snohomish, WA 98290
LICENSE #: CABLEL*97]DP EXP: 08/21/2019
TIE IN AT THE POLE, RISER DOWN; BORE AND PLACE 2-2" CONDUITS 94SOUTH. SETA 17"X30" VAULT AT THE BACK OF
THE SIDEWALK WITH A 2 PORT TAP; CONTINUE TO PRIVATE PROPERTY AND TO THE BUILDING.
DISRIJPTION INFORMATION
ASSESSED VALUE: $0.00 PROPERTY AREA: 0
SIDEWALK: (OXO) DURATION IN MONTHS: 0 FEE: $0 00 STREET DISRUPTION TRENCH CUT: ( 0 X 0 )
PARKING: ( OXO) DURATION IN MONTHS: 0 FEE: $0 00 YEAR OF OVERLAY: 0 FEE: $0 00
ALLEY: ( OXO) DURATION IN MONTHS: 0 FEE: $0.00
INDEMNITY The Applicant has signed an application which stales he/she holds the City of Edmonds harmless from injuries,
damages or claims ofany kind or description whatsoever, foreseen or unforeseen, that may be made against the City of Edmonds or
any ofits departments or employees, including but not limited to the defense ofany legal proceedings including defense costs and
attorney fees by reason ofgranting this permit.
THE CONTRACTOR IS RESPONSIBLEFOR WORKMANSHIP AND MATERIALS FOR A PERIOD OFONEYEAR FOLLOWING THE FINAL
INSPECTION AND ACCEPTANCE OF THE W ORK.
• Traffic Control and public safety shall be in accordance with City regulations as required by the City Engineer. Every flagger must
be trained as required by (WAC) 296-155-305 and must have certification verifying completion of the required training in their
possesion.
• Restoration is to be in accordance with City codes. All street -cut trench work shall be patched with asphalt or City approved
material prior to the end of the workday- NO EXCEPTIONS.
• Three sets of construction drawings of proposed work are required with the permit application.
CALL DIALrA-DIG (1-800-424-5555) BEFORE ANY EXCAVATION
CALL FOR INSPECTION (425) 771-0220 EXT.1326
24 HOUR NOTICE REQ UIRED FOR ALL INSPECTION REQUESTS
APPLICATIONAPPROVAL
THIS APPLICATION IS NOT PERMIT UNTIL SIGNED BY THE CITY ENGINEER OR HIS/HER DEPUTY: AND FEES ARE PAID, AND RECEIPTIS ACKNOWLEDGED IN
SPACE PROVIDED
Printed: Tuesday, May 21, 2019
RELEASED BY
U7t11Iq
FILE COPY ❑ INSPECTOR COPY ❑ APPLICANT COPY
STATUS: ISSUED
ENG20190090
• Restore ROW to City standards
• Restore Landscape to like or better conditions.
• Call for locates of underground utilities prior to any excavation.
• Alert affected residents and/or businesses prior to work start.
• Conform to approved working drawings and Traffic Control plan.
• Public utilities maintain 5' separation from City Utilities.
• Verify clear bore crossings
• Utility patch restoration to be in accordance with Edmonds Standard detail E2.3
• Maintain erosion & sedimentation control. Keep street clean.
• Call for required inspections as noted.
• Traffic Control per approved plan and MUTCD. Refer to City of Edmonds traffic control requirements.
• Applicant shall repair/replace all damage to utilities or frontage improvements in City right-of-way per City standards that is
caused by or occurs during the permitted project.
• Sound/Noise originating from temporary construction sites as a result of construction activity are exempt fromthe noise limits
of ECC Chapter 5.30 only during the hours of 7:00amto 6:00pm on weekdays and 10:00am and 6:00pm on Saturdays, excluding
Sundays and Federal Holidays. At all other times the noise originating from construction sites/activities must comply with the
noise limits of Chapter 5.30, unless a variance has been granted pursuant to ECC 5.30.120.
• Applicant, on behalf of his or her spouse, heirs, assigns, and successors in interests, agrees to indemnify defend and hold
harmless the City of Edmonds, Washington, its officials, employees, and agents from any and all claims for damages of
whatever nature, arising directly or indirectly from the issuance of this permit. Issuance of this permit shall not be deemed to
modify, waive or reduce any requirements of any City ordinance not limit in any way the City's ability to enforce any ordinance
provision.
• E-Traffic Control
• E•Sidewalk Pre -Pour
• E•Final Restoration
• E-Engineering Final
• E•SidewalkPost-Pour
PARTIAL INSPECTION
PARTIAL INSPECTION
FINAL INSPECTION APPROVED
INSPECTIONS
DATE: INITIAL:
DATE: INITIAL:
DATE: INITIAL:
NOTES:
NOTES:
INC. 1 q)o
ROW PERMIT NO.: ENG
ISSUE DATE: S 1`
RIGHT-OF-WAY CONSTRUCTION MAR 1 -0 2019
PERMIT APPLICATION ENGINEERING DIVISION
PROJECT NAME:
CONTACT: Comcast - Jourden Lawrence
Cablecom LLC - Sunshine Crabbs
CONTRACTOR: Comcast / Cablecom LLC Phone #: Jourden Lawrence: 425-921-8201
Sunshine Crabbs: 360-863-2628 EX: 215
Mailing Address: Comcast- 1525 751h St SW Everett, WA 98203 Fax #:
Cablecom- 20021 120th Ave NE Bothell, WA 98001
State License #: CABLEL*971 DP Email #• Comcast - Jourden_Lawrence@comcast.com
Cablecom LLC - Snohomish.permitting@cablecomllc.net
City Business License #: NR-021818 Liability Insurance kZ Bonded
ADDRESS OR INTERSECTION OF CONSTRUCTION: 7416 212TH ST SW
ROW WORK ASSOCIATED WITH THE FOLLOWING TYPE OF PROJECT:
❑ Commercial ❑ Subdivision ❑ City Project ❑ Traffic Control (Only)
❑ Multi -Family ❑ Single Family
V EUC (PUD, VERIZON, PSE,
COMCAST, OVWSD):
Is this permit part of a blanket permit?
ANY ASSOCIATED PERMITS?
❑ Other
❑ Yes ❑ No
BLD# ENG#
DESCRIPTION OF PROPOSED WORK (Be Specific) : TIE IN AT THE POLE, RISER DOWN; BORE
AND PLACE 2-2" CONDUITS 94' SOUTH. SET A 17"X30" VAULT IN ROW WITH A 2 PORT TAP; CONTINUE TO PRIVATE PROPERTY
TO THE BUILDING.
11810
WAS STREET OVERLAYED WITHIN THE LAST FIVE 5 YEARS? YES F1 NO El Year:
PAVEMENT CUT: ❑v' Yes ❑ No If yes, indicate size of cut: 2 (5 x 3)
CONCRETE CUT: 0 Yes ❑ No If yes, indicate size of cut: x
RIGHT-OF-WAY
AREA
CLOSURE
TOTAL
DURATION
(NUMBER OF MONTHS)
Sidewalk 48 Hrs + LF
Alley 72 Hrs + LF
Parking 72 Hrs + LF
X
LF
SF
X
LF
SF
X
LF
SF
APPLICANT TO READ AND SIGN
*Traffic control and public safety shall be in accordance with City regulations as required by the City
Engineer. Every flagger must be trained as required by (WAC) 296-155-305 and must have certification
verifying completion of the required training in their possession.
*Restoration is to be in accordance with City codes and Standards. All street -cut trench work shall be
patched with asphalt or City approved material prior to the end of the workday — NO EXCEPTIONS.
Indemnity. The Applicant has signed an application which states he/she hold the City of
Edmonds harmless from injuries, damages or claims of any kind or description
whatsoever, foreseen or unforeseen, that may be made against the City of Edmonds or
any of its departments or employees, including defense costs and attorney fees by reason
of granting this permit.
I have read the above statements and understand the permit requirements and acknowledge that I must
follow all requirements in order for the permit to be valid.
SIGNATURE c DATE 3/11/2019
Co ractor or Agent
NO WORK SHALL BEGIN PRIOR TO PERMIT ISSUANCE
BUFFER DATA
LONGITUDINAL BUFFER SPACE = B
SPEED (MPH)
25
30
35
40
45
50
55
60
65
70
LENGTH (feet)
155
20D
25D
305
360
425
495
570
645
730
TMA ROLL AHEAD DISTANCE = R
HOST VEHICLE WEIGHT
9,900 TO 22,000 lbs
HOST VEHICLE WEIGHT
> 22,000 Ili
< 45 MPH
4--55 MPH
> 55 MPH
< 45 MPH
45-55 MPH
> 55 MPH
109
12S
172'
74'
100,
150'
PROTECTIVE VEHICLE (WORK VEHICLE) = R
NO SPECIFIED DISTANCE REQUIRED
CHANNELIZING DEVICE SPACING (FEET)
MPH
TAPER
TANGENT
50160
35/45
40
30
80
60
25/30
20
40
G ZO-Z
N /;ppliwnt shall fepoiNraplacP, A to
tltiliths orfrantage im;unvam-z nt-j in rlfy
right- ref -way per City stundardb -that is cmiscd
• Ur OC"' ire r!„�inrf fhP ^^rr;';+•^ � �>r•)}fa:i.
TW&KrLlx
� t`rFr�n
`al'ID�.JAt.1L UOW A•REAO.'
MINIMUM TAPER LENGTH = L (feet)
Lane
Width (feel}
Posted Speed (mph)
25 30 35 40 45 50 55 60 65 70
10
105
150
205
270
450
500
550
-
-
-
11
115
165
225
295
495
550
605
660
-
-
12
125
180
245
320
E.40
600
660
720
-
212TH ST SW —
T
b b
X
X
SIGN SPACING = K (FEET) (1 )
RURAL HIGHWAYS 60M5 MPH
800'*
RURAL ROADS 45155 MPH
500'*
RURAL ROADS & URBAN ARTERIALS 35140 MPH
350'*
RURAL ROADS, URBAN ARTERIALS 25130 MPH
RESIDENTIAL & BUSINESS DISTRICTS
200'* (2)
URBAN STREETS 25 MPH OR LESS
100'* (2)
ALL SIGNS ARE 48" X 48" BLACK ON ORANGE UNLESS OTHERWISE
DESIGNATED.
(1) All spacing may be adjusted to accommodate interchange
ramps, at -grade Intersectons, and driveways
(2) This spacing may be reduced in urban areas to fit roadway
conditions.
R4-76 KEEP W1-4L W20-1
24" x 3a' RQAD
Brvv Wo
RIGHT vvD� w /4L K C Lobcp' HEAD
/ l A
3U MIN.
20. 100' MAX. R B L/2 X X SIDC W hLl LW," /*11 O' t) ' ,
FOR TMA / I �
I DI DI
12 WORK AREA
13 ® ®��El — T- 2ft min. recommended
QL — — — — — — —
I I T T
L L mm"W
ROAD
WQ.Z STAGING ON BOTH SIDES OF THE STREET
AHEADJ ALTERNATELY
N SIGN LOCATION
® SIGN LOCATION - 5' MOUNTING
HEIGHT - RECOMMENDED
E9 ® ® CHANNELIZING DEVICES
PROTECTIVE VEHICLE REQUIRED
f4J-16¢
CLOSED
AHEAD
DEVICE SPACING 112 DISTANCE FOR
OPPOSING TRAFFIC DEVICES WNIGINE `=fjc
NOTES -----
1. For long term projects, conflicting pavement markingsno�longerlSw < 15 POP- A.P?t112, 4Ub of
applicable must be removed or obliterated as soon as practicable.won`l� w LTµIN TK6. (LI(�H7
Temporary markings shall be used as necessary and signs shall OF wa4 oNW.
be post mounted.
2. For speed limits of 30 mph or less, use sign W1-3 in lieu of sign W1-4.
3. Extend device taper across shoulder if applicable.
4. Protective vehicle with TMA required for roadways 45 mph or higher.
For roads 40 mph or less - shall be a work vehicle placed strategically
to shield work area.
311810 I NORTHPOINT WASHINGTON LLC I 7416 212TH .ST SW EDMONDS TC P
Prepared By: Kent Holland - (206) 914-5046 TIE IN AT THE POLE, RISER DOWN; BORE AND PLACE 2-2" CONDUITS 94' SOUTH. SET A
Rev Date 17" X 30" VAULT IN ROW WITH A 2-PORT TAP INSIDE, CONTINUE BORE TO PRIVATE
Date: PROPERTY, DIG AND INTERCEPT EMPTY 2" CONDUIT THAT RUNS TO BUILDING. 2"
ENGINEERED FOR: S001 SMB CONDUIT COMES INTO BUILDING IN CRAWL SPACE UNDER MODEM LOCATION, MAKE
CableComCasey Brown - (425) 754-0064 ONE CORE HOLE UP INTO MODEM LOCATION. LEAVE RG6 COIL FOR INSTALL.
145 Ccomcast Comcast ope
CNG';.okq 0oR0
ryo
L1J
0.
Ccomcast
C3:
fahleCom
ENGINEERED FOR:
6rSt,
Ir I
.'COMC
1\
206TH ST SW y
NORTHPOINT WASHINGTON LLC o Q 2
W
N 0p ^ >
311810 a
a a
209TH ST SW Cityufl.ynnw�>.xl
209TH ST SNl 209'
TH 5i SW
^ I �
^
7416 212TH ST SW W y'rj4
Vl ? 4
a o Z 10TH ST SW 5 t `� 1210TH - ST SW
EDMONDS W < - :; — ,Y
m
m
211
ST SW a I ^ r---� .
CONTACT PERSON: 4W4 J -1 1 r --
1418 12TH 9T 5W, FpMONDS, a8026-fa
T W - 3 (HqL' AVF i
(:ir% of I•:.Imun.l. fi
CableCom LLC Comcast 2137H ST SW `---� - —i >
_i
Supervisor Casey Brown - (425) 214T11 PL SW 111 '* o�`ON T —
Kent Holland - (206) 754-0064 215TH ST SW 215TH ST SW A I -_ _ I iF.
-�
914-5046 215TH PL sw a _' I 1.__� i I FIf - -
1316 Bonneville Ave 1525 75 St. SW #200 + i
216TH 5T SW w w ^ 216TH f
Snohomish, WA 98290 Everett, Washington 98203 > ST Sw
4 216iH -- ST SW^ _
' r City of Jlnunrlake Terrace
218TH ST SW ; L^
SHEET INDEX: y 21�i" ST SW
1 y
i- . I` 219TH ST SW - a a
1- COVER SHEET/PROJECT LOCATION 219THSTSW y
20TH ST SW _ IL �l— }
2 -LEGEND a
3 - SOW OVERVIEW MAP
4 - DETAIL VIEW l q 220TI4 PL SW
;. ^'• 221ST ST SW
SOUTH
PROJECT LOCATION RE 9
MAC 9 201 cs�'
JT # 311810 FILE NAME: NORTHPOINT WASHINGTON LLC
SHEET
ASBU I LD 1 OF 4
DATE: 5/7/2019 NUMBER:
THIS IS PROPRIETARY INFORMATION— NOT FOR DISTRIBUTION
Call out box
Pole
Potential hard surface restoration location
(layer is transparent can go over the top of
other labels)
000' Footage call out
New Bullet Ped
I �
Dig and intercept location
Existing Bullet Ped
(layer is transparent can go over the
top of other labels)
New Strand/Coax
Overlash to existing
strand
(�1
Utility Pothole
New Doghouse \
New Riser
Cathouse
S' x 3' Bore Pit
Existing Riser
Existing Doghouse
\ Cathouse
New ROW
GAS
Existing ROW
New Vault
U/G
— - — —
WATER
Existing Vault
New Private
PHONE
Existing
Private U/G
Lock Box
FIBER
New Building
exterior
Junction Box
ELECTRIC
Existing Building
exterior
• 0 • • • • •
• • • • 0 SEWER
New Building
® Core drill
` interior
Existing Building
Firewall
A A STORM DRAIN
„= ov®C=®mo
interior
penetration
311810
NORTHPOINT WASHINGTON LLC
7416 212TH ST SW
EDMONDS
Legend for SOW (1)
Prepared By:
Kent Holland - (zoe) eia-soae
Rev
Date
TIE IN AT EXISTING SYSTEM AT POLE, RISER DOWN2"CONDUIT AND BORE AND PLACE 2-
'
C3Date:
2" CONDUITS 94' SOUTH. SET A 17" X 30" VAULT AT THE BACK SIDE OF THE SIDEWALK
ENGINEERED FOR:
S001 SMB
CONTINUE BORE TO PRIVATE PROPERTY, DIG AND INTERCEPT EMPTY 2" THAT RUNS TO
CableCom
BUILDING.
Y
comcast:
Casey Brown - (425) 754-0064
Comcast OPE
r
i ALL MEASUREMENTS ARE
` TAKEN FROM CENTER LINE
r
6'
()
--- - -- c — �--- s — - — S — 2 s bu � R (f��,c,E a t•n�-� �� A PP(��c•. Lo Vt'rr a;�._
J
14
c.
t )lI6 C.A4A, 1F0% '�O(A-PTI�Ls
t
9A%.
m wl fV y1 M
S 1{uOztton►7�L i' VErz►tc� L
r-kr1 �t�� v-c�t,t-r►�s.
or
(Lzo21!cYION .v1kmcIM
f:4.16 212TH ST SW, EDMONDS. 980�6-70"
ttttttttttttt� __ _ � _ t� �tR�
311810
NORTHPOINT WASHINGTON LLC
7416 212TH ST SW
EDMONDS
Hand Off
C3:
CableCom
Prepared By:
Kent Holland - (206) 914-SO46
I
Rev
1
Date
1
TIE IN AT EXISTING SYSTEM AT POLE, RISER DOWN2"CONDUIT AND BORE AND PLACE 2-
2" CONDUITS 94' SOUTH. SET A 17" X 30" VAULT AT THE BACK SIDE OF THE SIDEWALK
CONTINUE BORE TO PRIVATE PROPERTY, DIG AND INTERCEPT EMPTY 2" THAT RUNS TO
BUILDING.
Date:
ENGINEERED FOR:
S001 SMB
c—m caSt
Casey Brown - (425) 754-0064
Comcast OPE
IUT► .
r r
Imo
lilt
ri
WY
EW
I J.—
A
r
F_ Date: 6-Mar-19
ENGINEERED FOR:
Ccomcast.
ir
110011111111111111111111
le
P" j