Issued ROW Permit Revision 3.21.19.pdff CITY OF EDMONDS
L J
121 5TH AVENUE NORTH - EDMONDS, WA 98020
PHONE: (425) 771-0220 - FAX: (425) 771-0221
*PERMIT MUST BE POSTED ON JOBSITE*
STATUS: ISSUED ENG20190071
RIGHT OF WAY PERM IT (6-EUC)
Permit Number: ENG20190071 Expiration Date: 09/06/2019
Job Address: 20105 MAPLEWOOD DR, EDMONDS Location: 20105 MAPLEWOOD DR
PSE/Infras ource
P SE/Infrasource
C/O Susan att: Sidick
C/O Susan att: Sidick
1660 Park Lane
1660 Park Lane
Burlington, WA 98233
Burlington, WA 98233
(425)457-6353
LICENSE #: infrasl871 c2 EXP: 02/22/2019
Work area is approx 21' W to 8' E c/l of Maplewood Dr. & 80' N c/1 of Cascade Dr. (1) 3x5 gravel and (1) 3x5 paving cut anticipated to
install gas service.
Revision: e)dended to 110' N c/l of Cascade Dr.
DISRUPTION INFORMATION
ASSESSED VALUE: $0.00 PROPERTY AREA: 0
SIDEWALK: (OXO) DURATION IN MONTHS: 0 FEE: $0.00 STREET DISRUPTION TRENCH CUT: ( 0 X 0 )
PARKING: ( OXO) DURATION IN MONTHS: 0 FEE: $0.00 YEAR OF OVERLAY: 0 FEE: $0.00
ALLEY: ( OXO) DURATION IN MONTHS: 0 FEE: $0.00
INDEMNITY The Applicant has signed an application which states he/she holds the City of Edmonds harmless from injuries,
damages or claims ofany kind or description whatsoever, foreseen or unforeseen, that may be made against the City ofEdmonds or
any ofits departments or employees, including but not limited to the defense ofany legal proceedings including defense costs and
attorney fees by reason ofgranting this permit.
THE CONTRACTOR IS RESPONSIBLEFOR WORKMANSHIP AND MATERIALS FOR A PERIOD OFONEYEAR FOLLOWING THE FINAL
INSPECTION AND ACCEPTANCE OF THE W ORK.
• Traffic Control and public safety shall be in accordance with City regulations as required by the City Engineer. Every flagger must
be trained as required by (WAC) 296-155-305 and must have certification verifying completion of the required training in their
possesion.
• Restoration is to be in accordance With City codes. All street -cut trench work shall be patched with asphalt or City approved
material prior to the end of the workday- NO EXCEPTIONS.
• Three sets of construction drawings of proposed work are required with the permit application.
CALL DLAL-A-DIG (1-800424-5555) BEFORE ANY EXCAVATION
CALL FOR INSPECTION (425) 771-0220 EXT. 1326
24 HOUR NO TIC E REQ UIRED FOR ALL INSPECTION REQUESTS
THIS APPLICATION IS NOTA PERMITUNTIL SIGNED BY THE CITY ENGINEER OR HIS/HER DEPUTY: AND FEES ARE PAID, AND RECEIPT IS ACKNOWLEDGED IN
SPACE PROVIDED.
Printed: Thursday, March 21, 20191
PELEA4PYL9Y DATE
❑ FILE COPY ❑ INSPECTOR COPY ❑ APPLICANT COPY
STATUS: ISSUED
ENG20190071
• Restore ROW to City standards
• Restore Landscape to like or better conditions.
• Call for locates of underground utilities prior to any excavation.
• Alert affected residents and/or businesses prior to work start.
• Conform to approved working drawings and Traffic Control plan.
• Verify clear bore crossings
• Utility patch restoration to be in accordance with Edmonds Standard detail E2.3
• Maintain erosion & sedimentation control. Keep street clean.
• Call for required inspections as noted.
• Traffic Control per approved plan and MUTCD. Refer to City of Edmonds traffic control requirements.
• Applicant shall repair/replace all damage to utilities or frontage improvements in City right-of-way per City standards that is
caused by or occurs during the pemutted project.
• Sound/Noise originating fromtemporary construction sites as a result of construction activity are exempt fromthe noise limits
of ECC Chapter 5.30 only during the hours of 7:00am to 6:00pm on weekdays and 10:00am and 6:00pm on Saturdays, excluding
Sundays and Federal Holidays. At all other times the noise originating from construction sites/activities must comply with the
noise limits of Chapter 5.30, unless a variance has been granted pursuant to ECC 5.30.120.
• Applicant, on behalf of his or her spouse, heirs, assigns, and successors in interests, agrees to indemnify defend and hold
harmless the City of Edmonds, Washington, its officials, employees, and agents from any and all claims for damages of
whatever nature, arising directly or indirectly fromthe issuance of this permit. Issuance of this permit shall not be deemed to
modify, waive or reduce any requirements of any City ordinance not limit in any way the City's ability to enforce any ordinance
provision.
• E Final Restoration
• E-Engineering Final
PARTIAL INSPECTION
PARTIAL INSPECTION
FINAL INSPECTION APPROVED
DATE:
DATE:
INITIAL: NOTES:
INITIAL: NOTES:_
DATE: INITIAL:
Of 1:U,k1( - ) .
jNC. 1 sgo
ROW PERMIT NO.: ENG 1,/ n
ISSUE DATE:
RIGHT-OF-WAY CONSTRUCTION i(� CEIVE
PERMIT APPLICATION MAR 212019
ENGINEERING DIVISION
PROJECT NAME: 106350826
CONTRACTOR: PSE/Infrasource
Mailing Address: 1660 Park Lane, Burlington, WA 98233
State License #: INFRASL871 C2
City Business License #: NR-025677
CONTACT: Sue Sidick
Phone #: 425-457-6353
Fax #:
Email #: Susan.Sidick@pse.com
❑ Liability Insurance ❑ Bonded
ADDRESS OR INTERSECTION OF CONSTRUCTION: 20105 Maplewood Dr
ROW WORK ASSOCIATED WITH THE FOLLOWING TYPE OF PROJECT:
❑ Commercial ❑ Subdivision ❑ City Project ❑ Traffic Control (Only)
❑ Multi -Family ❑X Single Family
❑ EUC (PUD, VERIZON, PSE,
COMCAST, OVWSD):
Is this permit part of a blanket permit?
ANY ASSOCIATED PERMITS?
❑ Other
❑ Yes ❑A No
BLD# ENG#
DESCRIPTION OF PROPOSED WORK (Be Specific) : Work area is approx 21' W c/1 of Maplewood Dr
& 8' E c/I of Maplewood dr to 110' N c/I of Cascade Dr (1) 3x5 gravel cut and (1) 3x5 paving cut anticipated
Permitted under # ENG20190071. Permit updated with additional job scope
WAS STREET OVERLAYED WITHIN THE LAST FIVE 5 YEARS? YES 0 NO 106COI
PAVEMENT CUT: ® Yes ❑ No If yes, indicate size of cut: 3 x 5
CONCRETE CUT: ❑ Yes ❑ No If yes, indicate size of cut: x_
RIGHT-OF-WAY
AREA
CLOSURE
TOTAL
DURATION
(NUMBER OF MONTHS)
Sidewalk 48 Hrs + LF
X
LF
SF
Alley 72 Hrs + LF
X
SF
Parking 72 Hrs + LF
X
JLF
SF
APPLICANT TO READ AND SIGN
*Traffic control and public safety shall be in accordance with City regulations as required by the City
Engineer. Every flagger must be trained as required by (WAC) 296-155-305 and must have certification
verifying completion of the required training in their possession.
*Restoration is to be in accordance with City codes and Standards. All street -cut trench work shall be
patched with asphalt or City approved material prior to the end of the workday — NO EXCEPTIONS.
Indemnity: The Applicant has signed an application which states he/she hold the City of
Edmonds harmless from injuries, damages or claims of any kind or description
whatsoever, foreseen or unforeseen, that may be made against the City of Edmonds or
any of its departments or employees, including defense costs and attorney fees by reason
of granting this permit.
I have read the above statements and understand the permit requirements and acknowledge that I must
follow all requirements in order for the permit to be valid.
D'e
Susan Sidick naM.Ibfs.a+�
DN: c�•\'ain G6G.. .Pnma•op Depatlmenl, °u=Municipal 03/21 /2019
SIGNATURE : `.�"w`.n`0700 `am. U3 DATE
Dale: T i0 O] ]� 11013. %00'
Contractor or Agent
NO WORK SHALL BEGIN PRIOR TO PERMIT ISSUANCE
Job #:
Date:
Jurisdiction:
ROW Permit:
Est. Start Date:
Est. Duration:
106350826
2/19/19
edmonds
Yes
4/1 /19
1 Day 8 Hours)
Puget Sound Energy Gas Pre -Inspect Form
Address: 20105 MAPLEWOOD DR
City / zip: Edmonds, 98026
Customer: Aaron Cummings 425-361-6591
PM / Inspector: Brian Buschbom (425) 659-0673
Job Description
Scope of Work
Off of 2" STW main in Maplewood Dr - Install an all new 1-1/8" PE service ( 54' Scat ROW / 35'
NewConstruction:
Plat Prop) and then set an A425 O/L.
Yes
Construction Method
Scat ROW / Plat Property
PLAT Map: 162068
t' E C I V E D
P/L ROW 60 FT
P/L
CII_
'
MAR 212019
•g
4Po
ENGINEERING DIVISION
r
. j r
•
.
————
I
+
I
I
20105
I
• r
�
IL •
•
•;
a.
S
Call for Locates
l It •
ti
Verify Clear Bore Crossings
- ---i
-Must maintain a minimum 5' Horizontal & 1'
•
%
vertical separation from city utilities.
1
�
� 1
ti �
•
a
•
Cascade Dr
Work Location
Size of Cut
Surface Type
21'
West
of CL
Maplewood Dr
&
110'
North
of CL
Cascade Dr
3'x5'
Gravel
8'
East
of CL
Maplewood Dr
&
110'
North
of CL
Cascade Dr
3'x5'
Asphalt
of CL
&
of CL
of CL
&
of CL
of CL
&
of CL
Service Information
Street Information
Job Type
Diameter:
1-1/8" PE
Flaggers #:
Arterial:
New Residential Svc
EFV:
1-1/8" - 2600 - 9999144
Police #:
TCP:
Tie -In Fitting
Meter:
A425
Speed Limit:
No Parks #:
Steel - 1" Sery x 1/8" PE Outlet (MOP)
125 (3/4" Cutter)
Meter Loc:
08 - OR
Trolley Lines:
Mtr Hoods #:
Del Press:
6" W.C.
Traffic Signal:
Bus Stop:
Bollards:
2.5" # 1 4" # I
ADA Ramps #:I
I Route #'s:
Puget Sound Energy
Traffic Control Supervisor:
Gregory Harwood
Card No. 008997
Card Exp. 08/13/2019
gregory.harwood@pse.com
TEMPORARY TRAFFIC CONTROL PLAN
Notes:
1. All signs and spacing to conform to the MUTCD
and City of Edmonds standards.
2. All sidewalks, driveways, exits and egresses
shall be completely clear unless otherwise indicated.
3. Channelizing devices are 28" traffic cones.
Use traffic drums (barrels) with steady burning
Type C lights on all State Routes and Hwys.
4. Sign size can be a minimum of 36" x 36" and shall
not obstruct pedestrian access.
5. Crew is required to leave a minimum of 11' for
traveling lane width.
6. Alert affected residents and businesses.
7. Work to take place between-9 a.m. and &.m
unless otherwise specified. All work for arterials
and major roadways will be from 9 a.m. to 3 p.m
8. Work area will be 21' WCL on Maplewood Dr and
80' NCL on Cascade Dr. Then 8' ECL on Maplewood
Dr and 80' NCL on Cascade Dr.
9. If used, place NO -PARK signs 72 hours in
advance of the day that the work is to be done.
CASCADE DR
Q4°'2
N_
V
NJ
N
i
PUGET
SOUND
ENERGY
JOB# 106350826
20105 MAPLEWOOD DR, EDMONDS, WA 98026
02/20/19
JOHN.CROFOOT@PSE.COM
425-424-6658
SHEET 1 of 2
�- &20-2
o
0
I
I•• I
C:=3
9NIK2Nd ® I
I
I
pARKNG
p O
20105
�-RECEIVING PIT
MINIMUM TAPER LENGTH=L (FT.)
LANE
POSTED
SPEED (MPH)
WIDTH
20
25
30 35
40 45 50
55 60 65 70
10
70
1105115012051270
475
500
550
-
-
11
75
115
165
225
295
495
550
605
660
-
12
80
125
180
245
320
540
600
660
720
780
840
------------------ A ------- -I --------------- r----
202ND PL SW
CIL - - - - 15111
Puget Sound Energy
Traffic Control Supervisor:
Gregory Harwood
Card No. 008997
Card Exp. 08/13/2019
gregory.harwood@pse.com
TEMPORARY TRAFFIC CONTROL PLAN
Notes:
1. All signs and spacing to conform to the MUTCD
and City of Edmonds standards.
2. All sidewalks, driveways, exits and egresses
shall be completely clear unless otherwise indicated.
3. Channelizing devices are 28" traffic cones.
Use traffic drums (barrels) with steady burning
Type C lights on all State Routes and Hwys.
4. Sign size can be a minimum of 36" x 36" and shall
not obstruct pedestrian access.
5. Crew is required to leave a minimum of 11' for
traveling lane width.
6. Alert affected residents and businesses.
7. Work to take place between-0 a.m. and i6p.m
unless otherwise specified. All work for arterials
and major roadways will be from 9 a.m. to 3 p.m o
8. Work area will be 21' WCL on Maplewood Dr and
80' NCL on Cascade Dr. Then 8' ECL on MaplewoW
Dr and 80' NCL on Cascade Dr.
9. If used, place NO -PARK signs 72 hours in
advance of the day that the work is to be done.
a��
CASCADE DR
"--A,
N
0
D
- — - — - — - — -- -- - — -- — - — -- ---
LEGEND
® 28" TRAFFIC CONE
WORK PIT
TRAFFIC FLOW
FLAGGER
WORK VEHICLE/
FLASHING LIGHTS
SIGN LOCATION
RIGHT OF WAY
ROW ROW—
,00 L ' .001. 1,00
=oo
0a
�0 OO m
W20-1 m W20-7A
CHANNELIZATION
DEVICE SPACING
MPH
TAPER
TANGENT
55/70
40
80
35/45
30
60
25/30
20
40
MINIMUM TAPER LENGTH=L (FT.)
LANE
WIDTH
20
25
POSTED SPEED (MPH)
30 35 40 45 50
55 60 65 70
10
70
105
150
205
270
475
500
550
-
I -
-
11
75
115
165
225
295
495
550
605
660
-
-
12
80
125
180
245
320
540
600
660
720
780
840
PUGET
SOUND
ENERGY
JOB# 106350826
20105 MAPLEWOOD DR, EDMONDS, WA 98026
02/20/19
JOH N.CROFOOT@PSE.COM
425-424-6658
' C-ZO-2
t
20105
EIVING PIT
CONTRACTOR TO POTHOLE EXISTING
UTILITIES PRIOR TO WORK START
1�
,\ �o N
pH�
_ 11\ o YjO N
O
C�Zo-Z�
1
1�
I
�I
I
I
I
i
I
SHEET 2 of 2
V!"
---
--- ! ---------------
------- J----- 1------------------------t----1--
202ND PL SW
vA, o, rV
CITY OF EDMONDS
121 5TH AVENUE NORTH - EDMONDS, WA 98020
PHONE: (425) 771-0220 - FAX: (425) 771-0221
*PERMIT MUST BE POSTED ON JOBSITE*
STATUS: ISSUED /NG20190071 �
Permk Number: ENG20190071 Exp' tion Date: 09/06/2019
Job Address: 20105 MAPLEWOOD DR, EDMONDS Location: 105 MAPLEWOOD DR
APPLICANT CONTRACTOR
PSE/Infras ource P SE/Infrasource Q
GO Susan att: Sidick C/O Susan att: Sidick �(
1660Park Lan e 1660 Park Lane -++
Burlington, WA 98233 Burlington, WA 98233
(425)457-6353
LICENSE #: infrasl871 /EXP:22/2019
Work area is approx 21' W to 8' E c/l of Maplewood Dr. & 80' N c/1 of Cascade Dr. (1 x6 gravel and (1) 3x5 paving cut anticipated to
install gas service.
ASSESSED VALUE: $0.00 PROPERTY AREA: 0
SIDEWALK: (OXO) DURATION IN MONTHS: 0 FEE: $0.00 STREET DISRUPTION TRENCH CUT: ( 0 X 0 )
PARKING: (OXO) DURATION IN MONTHS: 0 FEE: $O. YEAR OF OVERLAY: 0 FEE: $0 00
ALLEY: (OXO) DURATION IN MONTHS: 0 FEE: $ 0
INDEMNITY The Applicant has signed an application which .sta s he/she holds the City of Edmonds harmless from injuries,
damages or claims ofany kind or description whatsoever, forese r or unforeseen, that may be made against the City of Edmonds or
any ofits departments or employees, including but not limited o the defense ofany legal proceedings including defense costs and
attorney fees by reason ofgranting this permit.
THE CONTRACTOR IS RESPONSIBLE FOR WORKMANfP AND MATERIALS FOR A PERIOD OFONEYEAR FOLLOWING THE FINAL
INSPECTION AND ACCEPTANCE OFTHEWORK.
• Traffic Control and public safety shall be in acc dance with City regulations as required by the City Engineer. Every flagger must
be trained as required by (WAC) 296-155-305 id must have certification verifying completion of the required training in their
possesion.
• Restoration is to be in accordance with Ci codes. All street -cut trench work shall be patched with asphalt or City approved
material prior to the end of the workday- O EXCEPTIONS.
• Three sets of construction drawings o roposed work are required with the permit application.
CAL JAL -A -DIG (1-800-424-5555) BEFORE ANY EXCAVATION
CALL FOR INSPECTION (425) 771-0220 EXT.1326
4 HOUR NOTICEREQUIRED FOR ALL INSPECTION RFQ I`RSTS
THIS APPLICATION IS NOTA PERM UNTIL SIGNED BY THE CITY ENGINEER OR HIS/HER DEPUTY: AND FEES ARE PAID, AND RECEIPTIS ACKNOWLEDGED IN
SPACE PROVIDED
Printed: Wednesday, March 06, 2019
3/6/2019
RELEASED BY DATE
❑ FILE COPY ew INSPECTOR COPY D APPLICANT COPY
STATUS: ISSUED ENG20190071
• Restore ROW to City standards
• Restore Landscape to like or better conditions.
• Call for locates of underground utilities prior to any excavation.
• Alert affected residents and/or businesses prior to work start.
• Conform to approved working drawings and Traffic Control plan.
• Verify clear bore crossings
• Utility patch restoration to be in accordance with Edmonds Standard detail E2.3
• Maintain erosion & sedimentation control. Keep street clean.
• Call for required inspections as noted.
• Traffic Control per approved plan and MUTCD. Refer to City of Edmonds traffic c trol requirements.
• Applicant shall repair/replace all damage to utilities or frontage improvements ii ity right-of-way per City standards that is
caused by or occurs during the permitted project.
• Sound/Noise originating fromtemporary construction sites as a result ofco traction activity are exempt from the noise limits
of ECC Chapter 5.30 only during the hours of 7:00am to 6:00pm on weekd sand 10:00am and 6:00pm on Saturdays, excluding
Sundays and Federal Holidays. At all other times the noise originating om construction sites/activities must comply with the
noise limits of Chapter 5.30, unless a variance has been granted purl nt to ECC 5.30.120.
• Applicant, on behalf of his or her spouse, heirs, assigns, and succe ors in interests, agrees to indemnify defend and hold
harmless the City of Edmonds, Washington, its officials, employe , and agents from any and all claims for damages of
whatever nature, arising directly or indirectly from the issuance f this permit. Issuance of this permit shall not be deemed to
modify, waive or reduce any requirements of any City ordinan not limit in anyway the City's ability to enforce any ordinance
provision.
• E-Final Restoration
• E-Engineering Final
PARTIAL INSPECTION DA
PARTIAL INSPECTION DA
FINAL INSPECTION APPROVED DA
INITIAL: NOTES:
INITIAL: NOTES:
INITIAL:
of EU,trp����
�Nc. 1 s90
FEB 2 6 2019 ROW PERMIT NO.: ENG ),O c 671
I r-r-RINS VISION ISSUE DATE: 3
ENG
RIGHT-OF-WAY CONSTRUCTION
PERMIT APPLICATION
PROJECT NAME: 106350826
CONTRACTOR: PSE/Infrasource
Mailing Address: 1660 Park Lane, Burlington, WA 98233
State License #: INFRASL871 C2
City Business License #: NR-025677
CONTACT: Sue Sidick
Phone #: 425-457-6353
Fax #:
Email #: Susan.Sidick@pse.com
Liability Insurance ❑ Bonded
ADDRESS OR INTERSECTION OF CONSTRUCTION: 20105 Maplewood Dr
ROW WORK ASSOCIATED WITH THE FOLLOWING TYPE OF PROJECT:
❑ Commercial ❑ Subdivision ❑ City Project ❑ Traffic Control (Only)
❑ Multi -Family ❑X Single Family ❑ Other
❑ EUC (PUD, VERIZON, PSE,
COMCAST, OVWSD):
Is this permit part of a blanket permit? ❑ Yes *❑ No
ANY ASSOCIATED PERMITS? BLD# ENG#
DESCRIPTION OF PROPOSED WORK (Be Specific) : Work area is approx 21' W to 8' E c/1 of
Maplewood Dr & 80' N c/I of Cascade Dr. ()1) 3x5 gravel and (1) 3x5 paving cut anticipated
WAS STREET OVERLAYED WITHIN THE LAST FIVE (5) YEARS? YES ❑ NO ❑ Year: 106iy
PAVEMENT CUT: ❑ Yes ❑ No If yes, indicate size of cut: 3 x 5
CONCRETE CUT: ❑ Yes ❑ No If yes, indicate size of cut: x
RIGHT-OF-WAY
AREA
CLOSURE
TOTAL
DURATION
(NUMBER OF MONTHS)
Sidewalk 48 Hrs + LF
X
LF
LF
SF
Alley 72 Hrs + LF
X
SF
Parking 72 Hrs + LF
X
LF
SF
APPLICANT TO READ AND SIGN
*Traffic control and public safety shall be in accordance with City regulations as required by the City
Engineer. Every flagger must be trained as required by (WAC) 296-155-305 and must have certification
verifying completion of the required training in their possession.
*Restoration is to be in accordance with City codes and Standards. All street -cut trench work shall be
patched with asphalt or City approved material prior to the end of the workday — NO EXCEPTIONS.
Indemnity. The Applicant has signed an application which states he/she hold the City of
Edmonds harmless from injuries, damages or claims of any kind or description
whatsoever, foreseen or unforeseen, that may be made against the City of Edmonds or
any of its departments or employees, including defense costs and attorney fees by reason
of granting this permit.
I have read the above statements and understand the permit requirements and acknowledge that I must
follow all requirements in order for the permit to be valid.
Susan Sidick RaialY.q.""' "'� 02/26/2019
OWc &l S*M wwme.q Npan i, ou=Munitlpel
SIGNATURE Da,:2°` 02M1 :18-M' ".�m,`=°5 DATE
oafs: zois oz zs ta:ze:ia-oe•ao•
Contractor or Agent
NO WORK SHALL BEGIN PRIOR TO PERMIT ISSUANCE
Puget Sound Energy Gas Pre -Inspect Form
Job #:
106360826
Date:
2/19/19
Address:
20105 MAPLEWOOD DR
Jurisdiction:
edmonds
City/Zip:
Edmonds, 98026
ROW Permit:
Yes
Customer:
Aaron Cummings 425-361-6591
Est. Start Date:
4/1/19
PM / Inspector:
Brian Buschbom (425) 659-0673 <�
Est. Duration:
1 Day (8 Hours)
Job Description Scope of Work
Off of 2" STW main in Maplewood Dr
- Install an all new 1-1/8" PE service (54' Scat ROW / 35'
New G(onstruction:
Plat Prop) and then set an A425 O/R.
Yes
Construction Method
Scat ROW / Plat Property
PLAT Map: 162068
� C_.kLL. I-OCA-7 ES
GI.�A(L &(C(% 0-0$9
S
ROW 60 FT
PIL `
P/L ..�C MQ S2 KA-i /V 1 hl/J A, MIN, tl0 S ' 110 12E
SC�iAR ioN
'= 0
N ,v, o
� VJ-T GITItS
U� a
,
`
I
i 20 5
-------------
`
---------
I
' sa
; I 35
ti
ascade Dr
Work Location
Size of Cut
Surface Type
21'
West
of CL
Mapj wood Dr
&
80'
North
of CL
Cascade Dr
3'x5'
Gravel
8'
East
of CL
TP-
Maplewood Dr
&
80'
North
of CL
Cascade Dr
3'x5'
Asphalt
Of CL
&
of CL
Of CL
&
of CL
Of Of
&
of CL
Service Information
Street Information
Job Type
Diameter:
'IF--1/8" PE
Flaggers #:
Arterial:
New Residential Svc
EFV:
1-1/8" - 2600 - 9999144
Police #:
TCP:
Tie -In Fitting
Meter:
A425
Speed Limit:
No Parks #:
Steel
1" Sery x 1/8" PE Outlet (MOP)
125 (3/4" Cutter)
Meter Loc::'
08 - OR
Trolley Lines:
Mtr Hoods #:
Del Press:
6" W.C.
Traffic Signal:
Bus Stop:
Bollards:
2.5" # 1 14" # I
iADA Ramps #: