KPFF - Structural Engineering Phase 3 Final.pdf1601 Fifth Avenue, Suite 1600 Seattle, WA 98101 206.622.5822 kpff.com May 20, 2016 Mr. Craig Matheny NBBJ 223 Yale Avenue North Seattle, WA 98109 Subject: Swedish Edmonds Ambulatory Care Center, Phase 3 Statement of Structural Observations City of Edmonds Permit Number: BLD-2014-0238 Dear Craig: This letter serves to confirm that, to the best of KPFF's knowledge, Phase 3 of the Swedish Edmonds Ambulatory Care Center has been constructed in general conformance with the KPFF structural drawings and project specifications. As the Structural Engineer of Record, KPFF has performed structural observation of the construction in accordance with Section 1704.5 of the International Building Code. KPFF has also reviewed the inspection and testing reports supplied by Mayes Testing Engineers, Inc. Based on our observations, and the enclosed Final Letter of Structural Inspections and Testing from Mayes Testing, dated May 19, 2016, we know of no unresolved structural deficiencies. If you have any questions, please call me at (206) 622-5822. Sincerely, Thomas Hudgings, PE, SE Associate TRH:kjl 112555.30 Enclosure Jason Black, PE, SE Principal MAYES TESTING ENGINEERS, INC. May 16, 2016 (Revised May 19, 2016) City of Edmonds 121 5th Avenue N Edmonds, WA 98020-3146 Attention: Building Department Re: Swedish Edmonds Ambulatory Care Center Ph 3 Final Letter (Revised) 21601 76th Avenue West Permit: BLD-2014-0238 Edmonds, WA Project No. L15577 Seatlfe Office 20225 Cedar Valley Road Suite 110 Lynnwood, WA98036 ph 425.742.9360 fax425.745.1737 Tacoma Office 10029 S. Tacoma Way Suite E-2 Tacoma, WA98499 ph 253.584.3720 fax 253.584.3707 Portland Office 7911 NE 33rd Drive Suite 190 Portland, OR 97211 ph 503.281.7515 fax 503.281.7579 This is to inform you that registered special inspections have been completed for this project as per our reports, copies of which have been sent to you. Special inspection was provided for: • Concrete and Reinforcing • Post -installed Concrete Anchors • Base Plate Grouting • Structural Steel Erection: Welding and Bolting • Fireproofing: Spray -applied Coatings and Penetration Firestopping • Lateral Load Resisting Framing: Suspended Ceiling Systems To the best of our knowledge, all work inspected was either performed in accordance with, or corrected to conform to, the city approved drawings, or engineer approved changes. We trust this provides you with the information that you require. Should you have any questions please call us at 425/742-9360. Sincerely, Mayes Testing Engineer, Inc. Swedish Edmonds Ambulatory Care Center Ph 3 Michael S. Dolder, P.E. Vice President