KUPC Bond Corrections.doc
.
August 17, 2009
Korean United Presbyterian Church
ATTN: William Kang
th
8505 240 St SW
Edmonds, WA 98026
SUBJECT: Site Improvement Maintenance Bond, Church Expansion
Mr. Kang,
The City of Edmonds, Engineering Division, has performed the required two-year
maintenance inspection of the site improvements for the Korean United Presbyterian Church.
In order for the Site Improvement Maintenance Bond to be released the following corrections
must be made:
1. There are three areas of failed concrete. They are on the west side of the entrance/exit to
th
240. Photo #1 shows two of the cracks and Photo #2 shows the other crack. All panels will
need to be replaced from expansion joint to expansion joint. Also when replacing will need
to correct the slope of the panels in Photo #1 so that the water from the driveway will
continue into the gutter instead of the current panels which direct the water into the street.
Please note that contractors have been having less problems with cracking when using class
4000 concrete mix.
Photo 1
: #1 is a crack that goes through the gutter and the curb. #2 is a crack at the
driveway approach. An additional expansion joint may be added here so the whole panel
won’t have to be removed (see marking on photo).
Photo 2
: This shows the other panel on the western side of the exit/entrance. There is
a crack through the gutter and curb and also a chunk missing from the curb. Again an
additional expansion joint can be added here to avoid removing the entire panel.
Photo 3
: Please replace the thermoplastic missing on the “Y” in Yield.
Photo 4
: Remove all garbage and weeds from ditch area and trash rack. See attached
detail for reference. Filter fabric should not be visible and must be covered with rip
rap(quarry spall) at trash rack area.
Please call the Engineering Inspection line at 425-771-0220, ext. 1326 to request a final
inspection once the repairs are complete.
The City will allow for release of your maintenance bond when successful inspections are
complete.
Please feel free to call me with any questions you may have at 425-771-0220, ext. 1324.
Thank you,
JoAnne Zulauf
Engineering Technician
cc: Permit/Bond File
enc: photos