Lanning.pdf City of Edmonds PLAN REVIEW COMMENTS BUILDING DIVISION (425) 771-0220 DATE: July 16, 2008 TO: Design Works Construction, attention Mick E-mail: Mick@designworksconstruction.net FROM: Ann Bullis, Assistant Building Official RE: Plan Check: 2008-0510 Project: Lanning Addition/Remodel Project Address: 18604 Soundview Drive During review of the plans for the above noted project, it was found that the following information, clarifications or changes are needed. Please provide written responses to each comment as to how it has been addressed, and where changes can be found on the plans. Please submit revised plans/documents to Theresa Umbaugh, Senior Permit Coordinator. 1.Revise anchor bolt washer size to 3”x3”x.229”. 2.Provide manufacturer’s information for R21 rigid insulation to show that it will fit in the 2x4 stud bay. 3.Specify exterior sheathing material. 4.Note existing siding material that new addition will match. 5.Note ceiling finish material. 6.Note ceiling insulation R-value. 7.Note size of crawlspace access. 8.Provide detail of deck ledger bolted to new foundation as noted on Sheet A3. This is non- conventional construction, requiring the detail and calcs to be stamped and signed by a State licensed Professional Engineer (one copy wet signed). Also provide a detail where the deck will be bolted to the rim joist as shown on Section AA. 9.On Section AA revise 6” wood-earth dimension to be from the bottom of the sheathing/siding to the ground. 10.Provide hurricane clips as each end of each truss. 11.Dimension depth of foundation below grade (18” min.). 12.The new entry roof framing with knee brace supports is also beyond the scope of the IRC and must be designed and stamped by a State licensed Professional Engineer, including calcs (one copy wet signed). 13.Dimension 4’-0” braced wall panels on the floor plans (IRC 602.10).