Loading...
Letter of Incompleteness 05062010.pdf113 C, . :l Ball May 6, 2010 CITY OEDMONDS GARY HAAKENSON MAYOR 121 5TH AVENUE NORTH m EDMONDS, WA 98020 ® 425-771-0220 o FAX 425-771-0221 Website: wwwxi,edmondsma,us DEVELOPMENT SERVICES DEPARTMENT Robert Hughes Reed & Associates PS 8311 212th St SW Edmonds, WA 98026 Subject: Letter of Incompleteness — Gold Shoreline Substantial Development Permit Permit Number PLN20100027 Dear Mr. Hughes, The City of Edmonds has reviewed the application for a shoreline substantial development permit for the property located at 16200 75th Place West and 7510 162nd Street SW for completeness pursuant to Edmonds Community Development Code (ECDC) 20.55,010, 20.02.002, and WAC 173-27-180 and has found that more information is required for the application to be determined to be complete. The following items are required before the application can be deemed complete: 1. Landscape plan: WAC 173-27-180(9)(g) requires a landscaping plan for projects, where applicable. The geotechnical report from Nelson Geotechnical Associates, Inc. indicated that future vegetation management on the slope should be the subject of a specific evaluation and a plan approved by the City of Edmonds. Additionally, ECDC 23.10.210.D.3 states that all surfaces exposed during land surface modification must be revegetated or otherwise covered as quickly as possible to minimize erosion. Please submit landscape plans for the two properties. 2. Fill material: Pursuant to WAC 173-27-180(9)(1) provide the quantity, source and composition of any fill material that is placed on the site whether temporary or permanent. Pursuant to ECDC 23.10.205.1), the fill material must be nondissolving and nondecomposing. Both ECDC 23.10.205.D and ECDC 23.10.210.D.6 state the fill material must not contain organic or inorganic materials that would be detrimental to water quality or existing habitats. 3. Excavated material: WAC 173-27-180(9)0) requires the quantity, composition and destination of any excavated or dredged material. The two SEPA checklists for the project indicate there will be a combined 1832 cubic yards of cut for the two properties and 1705 cubic yards of fill. That means there is 127 cubic yards of material left over after the fill. Additionally the Nelson geotechnical report does not recommend the use of any of the on-site silt and clay soils be used as structural fill. Therefore, it appears that some material will have Incorporated Augyr.rsi:.N, 1890 Sister City - Hekinan, Japan to be hauled off site. Pursuant to WAC 173-27-180(9)0) please provide the quantity, composition and destination of the excavated material that will be hauled offsite. In addition to the completeness issues in items I — 3 above, during review of the application it was found that the following information, corrections, or clarifications need to be addressed. 4. Clearing limits and tree removal: ECDC 23.10.210.D.1 states that land surface modification must be the minimum necessary to accomplish the underlying reason for the land surface modification. ECDC 18.45.050 states that trees should be retained to the maximum extent feasible. Additionally, the Nelson geotechnical report recommends that the setback area at the top of slope not be disturbed or modified through placement of any fill or removal of the existing vegetation. The SEPA checklist indicates that all trees on site will be removed. The Clearing and Tree Removal Plan for the North House (BLD20100314) indicates that the clearing limits will be within the 20 -foot setback from the top of the slope. Clearing plans for the South House have not been submitted yet, but it appears from the site plan submitted with the shoreline permit application that clearing is proposed within the 20 foot setback for the South House as well. Please address the following items: a. Revise plans so that the clearing limits are outside of the 20 -foot setback from the top of the slope as recommended by the Nelson geotechnical report. b. Please show the 20 -foot setback line on the site plan for the South House. c. Indicate how removing all of the trees on site is consistent with ECDC 18.45.050, and if any trees are located within the 20 -foot setback from the top of the slope, they must remain consistent with the recommendation of the Nelson geotechnical report. 5. Lot lines and lot combination: The subject property consists of three parcels whose numbers and legal descriptions are: 00513106000100: MEADOWDALE BEACH BLK 060 D-00 - LOT 1 LESS CO RD PLUS VAC SEASIDE AVE LOT 2 LESS S IOFT PLUS VAC SEASIDE AVE 00513106000200: MEADOWDALE BEACH BLK 060 D-00 - S IOFT LOT 2 PLUS VAC SEASIDE AVE ALL OF LOT 3 PLUS VAC SEASIDE AVE 00513106000400: MEADOWDALE BEACH BLK 060 D-00 - TR 4 PLUS VAC SEASIDE AVE According to the site plans and SEPA checklists, the North House will be constructed on TPN 00513106000100 and the South House will be constructed on 00513106000200 and 00513106000400 with the South House split by the parcel lines. According to the legal, description, parcel 00513106000100 consists of Lot 1 and Lot 2 of Meadowdale Beach Block 60, less the southern 10 feet of lot 2. The legal description for parcel 00513106000200 consists of the southern 10 feet of lot 2 and all of lot 3 of Meadowdale Beach Block 60. It appears on the site plans that the southern 10 feet of Lot 2 has been added back to parcel 005 13 106000100. In order to develop the property as depicted on the site plans, a lot line adjustment must be applied for and approved before the building permits can be issued. Through the lot line adjustment process, the southern property line of 00513106000100 may recapture the southern 10 feet of Meadowdale Beach Block 60 Lot 2 and parcels 00513106000200 and 00513106000400 may be combined so that the proposed house is not spilt by a lot line. The lot line adjustment should also make clear that the line between Lot 1 and Lot 2 of Meadowdale Beach Block 60 (contained within 00513106000100) is also being dissovled. SEPA: Two SEPA checklists were submitted with the shoreline substantial development permit, one for the North House and a second for the Southern House and one SEPA fee was collected at the time of application. Since the City of Edmonds is treating the construction of the two houses as a single project for shoreline permitting purposes, the City will also combine the SEPA review of the two residences into a single SEPA review. If it was the applicant's intent to have separate SEPA reviews completed, an additional SEPA fee must be submitted. Please indicate whether the applicant would like to combine review under a single SEPA, or spilt the project into separate SEPA reviews. 7. Noticiniz: Pursuant to ECDC 20.03.001.A, the applicant is responsible for all posting, publishing, mailing and other notification. The project will have complicated notice requirements since shoreline permitting, SEPA and public hearing notices are all required. It is very important that notice be carried out in accordance with local and state noticing requirements. If notice does not happen according to code, the project could be delayed and hearings may have to be postponed and the project re -noticed. If the applicant wishes, the City is willing to conduct all the noticing for this project, however according to ECDC 20.03.004.E.2 the applicant will still be responsible for all costs associated with the public notice requirements. These costs include publishing notices in the Everett Herald, installation of a white notice board (which has all ready been paid for), and the cost of mailing. If the applicant wants the City to carry out the notice requirements for this proposal, please submit a letter to the City of Edmonds authorizing the City to carry out notice requirements. Please be aware that pursuant to ECDC 20.02.003.D.1 the applicant has 90 days to submit the necessary information. Ninety days from May 6, 2010 is August 4, 2010. If the additional information requested is not submitted within the 90 -day period, pursuant to ECDC 20.02.003.D.3 staff will make findings and issue a decision, according to the Type I procedure, that the application has lapsed for lack of information necessary to complete the review. I look forward to working with you on this project and feel free to contact me if you have any questions. Sincerely, Kernen Lien Associate Planner Cc: PLN20100027 File Mike Gold, Property Owner