Lighting Forms LTG15_Kahlo's Cantina.pdf2015 Washinqton State Enerqv Code Compliance Forms for Commercial Buildinqs includinq R2, R3, R4 over 3 stories and all R1 Revised Nov 2017
Project Title:
Kahlo'sCantina
Date
4/15/2019
Calculation
0 New Construction 0 Addition -
O Addition
For Building Department Use
NOTE 9
Area
stand alone
+ existing
O Spaces where < 50% of O Spaces where >_ 50% of
0 Spaces where the Use
luminaires are replaced luminaires are replaced
is changing (C505)
LPA
Standard 0 Additional Efficiency Package Option
Calculation
C406.3 Reduced Interior Lighting Power
To comply with C406.3, the Proposed LPD shall be 25% lower than the Target LPA.
Type
Refer to C406.3 for additional requirements.
User Note
Maximum Allowed Lighting Wattage
Location (plan #,
Ceiling
Gross Interior
Allowed
Watts Allowed
room #)
Space Type
Height NOTE 2
Area in ftZ
Watts per ftZ
(watts/ftZ x area)
Entry
Lobby: all other
182
0.720
131
Restrooms
Restroom: all other
260
0.780
203
Dining
Dining area: Family dining area
1325
0.710
941
Bar
Dining area: Bar/lounge/leisure dining
198
0.860
170
Kitchen
Food preparation
598
0.790
472
Storage
Storage room
309
0.500
155
Office
Office: Enclosed
58
0.890
52
Total Area 2930
Retail Display Allowance from
LTG-INT-DISPLAY
Lobby Art/Exhibit Display Allowance from LTG-INT-DISPLAY NOTE 87--�
Allowed Watts
2124
Proposed Lighting Wattage""'
Location (plan #,
room #)
Fixture Description NOTE 4, 5, 5
Number of
Fixtures
Wafts/
Fixture NOTE 7
j
Watts
Proposed
Entry
Can Light LED single lamp
2
25
50
Restrooms
Can Light LED single lamp
5
40
200
Dining
Can Light LED
33
25
825
Bar
Can Light LED
5
25
125
Kitchen
Can Light LED
1
25
25
Kitchen
2x4 Troffer LED 4 lamp
6
60
360
Storage
2x4 Troffer LED 4 lamp
3
60
180
Storage
Single Ceiling Mounted LED
2
60
120
Office
2x4 Troffer LED 4 lamp
j 1
j 60
60
Proposed Retail Display Lighting from LTG-INT-DISPLAYli
Total Proposed Watts may not exceed Total Allowed Watts for Interior Lighting Total Proposed Waftsl
1945
Interior Lighting Power Allowance COMPLIES
Note 1 - List all unique space types per Table C405.4.2(2) that occur in the project scope. Select space type category from drop down menu.
Note 2 - Indicate ceiling height for atriums and spaces utilizing the ceiling height adjustment per Table C405.4.2(2), Footnotes d thru f.
Note 3 - List all proposed lighting fixtures including exempt lighting equipment and existing -to -remain fixtures.
Note 4 - For proposed Fixture Description, indicate fixture type, lamp type (e.g. T-8), number of lamps in the fixture, and ballast type (if included). For
track lighting, list the length of the track (in feet) in addition to the fixture, lamp, and ballast information.
Note 5 - For lighting equipment eligible for exemption per C405.4.1, note exception number and leave Watts/Fixture blank.
Note 6 - Existing -to -remain fixtures shall be included in the Proposed Lighting Wattage table in the same manner as new fixtures. Identify as existing
in fixture description.
Note 7 - For proposed Watts/Fixture enter the luminaire wattage for installed lamp and ballast using manufacturer or other approved source. For
luminaires with screw -in lamps, enter the manufacturer's listed maximum input wattage of the fixture (not the lamp wattage). For low voltage
lighting, enter the wattage of the transformer. For line voltage track/busway systems, enter the larger of the attached luminaire wattage or 50
watts/lineal foot, or enter the wattage limit of permanent current limiting device.
Note 8 - Lobby Art/Exhibit Display Allowance is independent of the Maximum Allowed Lighting Wattage. Enter all proposed lobby art/exhibit display
fixtures in L TG-INT-DISPLA Y form only.
Note 9 - Calculation Area Details:
a. Lighting fixtures in a building addition may comply as a stand alone project, or they may be combined with the overall existing building
lighting systems to demonstrate compliance. Refer to C502.1. V V
For alterations and building additions, provide Space Types and gross interior areas in the Maximum Allowed Lighting Wattage table. If a
building addition will comply as combined with the overall existing building lighting systems, include all applicable existing Space Types
and gross interior areas.
If less than 50% of existing lighting fixtures will be replaced, provide total existing lighting wattage (prior to alteration) in the space provided
in the Maximum Allowed Lighting Wattage table.
If lighting alteration project includes some building areas or spaces where < 50% of luminaires are replaced, and other areas or spaces
where >_ 50% of luminaires are replaced, then these areas or spaces may be documented separately. If multiple forms will be completed
to demonstrate compliance for the total scope of the alteration project, describe scope covered in form in User Note section.
2015 Washinqton State Enerqv Code Compliance Forms for Commercial Buildinqs includinq R2, R3, R4 over 3 stories and all R1 Revised Nov 2017
Project Title: Kahlo's Cantina
Date 4/15/2019
Exterior Lighting
0 Zone 1 0 Zone 2 Zone 3 0 Zone 4
For Building Department Use
Zone
Exterior Lighting Zone selection required to enable LTG-EXT form.
Zones are defined in Table C405.5.2(1) and specified by the jurisdiction.
Calculation Area
0 New construction 0 Addition - stand alone 0 Addition
+ existing
0 Alteration with < 50% O Alteration with >_ 50% ext.
ext. wattage replaced wattage replaced
User Note
Building Grounds
❑ Efficacy> 80 lumens/watt ❑ Exemption
Applies to individual
❑ Controlled by motion sensor
luminaires > 100 Watts
Tradable Maximum Allowed Lighting Wattage NOTE, Base Site Allowance:
750
Area (ft), perimeter (If)
Allowed Watts
Allowed Watts
Tradable Surfaces
Surface Description
or # of items
per ft2 or per If
x ft2 (or x If) NOTE 2
Main Entry Door
Main Entry
6
30W/LF door
180
Other Entry Door
Patio Door
6
20W/LF door
120
Other Entry Door
Delivery/ Back of House
3
20W/LF door
60
Total Allowed Tradable + Site Allowance Watts:
1110
Tradable Proposed Lighting Wattage ""'
Tradable Surface
Fixture Description NOTE 415
Number of
Fixtures
Watts per
Fixture NOTE 6
Watts
Proposed
Main Entry Door
Wall pack LED (exit discharge light)
1
14
14
Other Entry Door
Wall pack LED (exit discharge light)
1
14
14
Other Entry Door
Wall pack LED (security light)
1
14
14
Total proposed tradable watts may not exceed the sum of total allowed tradable Total Proposed Tradable Watts:
watts nliic tha ha.ca city allnwanra Anv ha.ca .city allnwanra not naarlari to makes
42
tradable watts comply can be applied to individual non -tradable categories.
Non -Tradable Maximum Allowed Lighting Wattage ""' Site Allowance Remaining:
750
Non -Tradable Surfaces
Surface Description
Area (ft), perimeter (If)
or # of items
Allowed Watts
per ft2, If or item
Allowed Watts
x ft2 (or x If) NOTE 2
Bldg. Fagade
Building perimeter
246
0.113 W/ft2
28
Non -Tradable Proposed Lighting Wattage ""TE 3, 7
Non -Tradable Surface
Fixture Description NOTE 415
Number of
Fixtures
Watts per
Fixture NOTE 6
Watts
Proposed
Bldg. Fagade
Wall sconce LED
7
40
280
Non -tradable proposed watts may not exceed allowed watts for any individual Non -Tradable Watts Exceeding LPA: 252
surface unless the total excess watts for all non -tradable surfaces are less than the
remaining site allowance. Remaining Site Allowance: 498
Exterior Lighting COMPLIES WITH MAX. ALLOWANCE
Note 1 - List all exterior surfaces per Table C405.5.2(2) that occur in the project scope. Select exterior surface categories from drop down menu.
Note 2 - Unlit Message - Enter lighting fixture information for this surface in Proposed Lighting Wattage table to generate Lighting Power Allowance.
Note 3 - List all proposed lighting fixtures including existing -to -remain fixtures.
Note 4 - For proposed Fixture Description, indicate fixture type, lamp type, number of lamps in the fixture, and ballast type (if applicable).
Note 5 - Existing -to -remain fixtures shall be included in the Tradable and Non -Tradable Proposed Lighting Wattage tables in the same manner
as new fixtures. Identify as existing in fixture description.
Note 6 - For proposed Watts/Fixture enter the luminaire wattage for installed lamp and ballast using manufacturer or other approved source. For
luminaires with screw -in lamps, enter the manufacturer's listed maximum input wattage of the fixture (not the lamp wattage). For low
voltage lighting, enter the wattage of the transformer.
Note 7 - Automated Teller and Night Depositories - For each location, enter the number ofATM machines or depositories within that location. /f
there are multiple locations in the project, enter each location individually in the Non -Tradable Maximum Allowed Lighting Wattage table
and identify the location in the Surface Description section.
2015 Washinaton State Enerov Code Compliance Forms for Commercial Buildinas includina R2. R3. R4 over 3 stories and all R1 Revised Nov 2017
Project Info
Project Title: Kahlo's Cantina
Date 4/15/2019
Compliance
forms do not
Applicant Information. Provide contact information for individual who can
respond to inquiries about compliance form information provided.
For Building Department Use
require a
password to
Company Name: 2812 Architecture
Company Address: 2812 Colby Avenue
use.
Instructional and
calculating cells
are write -
protected.
Applicant Name: Jeff Stavert
Applicant Phone: (425) 252-2153
Applicant Email: jeff@2812architecture.com
Project Description
❑ New Building ❑� Addition ❑ Alteration ❑ No Lighting Scope
Include PROJ-SUM form (included in envelope forms workbook) with lighting compliance forms.
Interior Lighting System
Remodel of an existing restaurant. All new interior lighting & controls.
Description
0 Interior Lighting Plans Included
Interior Lighting Power
❑ Building Area Method 0 Space -by -space Method
Allowance Method
Select method used in project.
Interior Lighting Controls
❑� All C405.2.1 - C405.2.8 Lighting Controls ❑ C405.2 Exception 5 Luminaire Level
Lighting Controls (LLLC)
❑ Additional Efficiency Package Option
C406.4 Enhanced Digital Lighting Controls
To comply with C406.4, no less than 90% of the total installed interior lighting power shall comply with the
required controls per C406.4.
Dwelling Unit Interior
Permanently installed interior lighting fixtures in dwelling units comply with: 0 No Dwelling
Lighting
O C405.2 thru C405.5 Commercial Lighting Controls and LPA Units
O C406.3 High Efficacy Lighting
O R404.1 Residential High Efficacy Lighting. Dwelling unit lighting complies with WSEC Residential
provisions in lieu of WSEC Commercial provisions.
Exterior Lighting System
All new exterior lighting.
Description
0 Exterior Lighting Plans Included
Building Additions
Compliance Method
Interior lighting Exterior lighting
Lighting systems in addition area comply with all applicable
provisions as a stand alone new construction project
Refer to Section C502.2.6 for additional
requirements.
El ❑
Lighting systems in addition are combined with existing
lighting systems to demonstrate compliance
El
El
Addition is combined with existing:
For interior lighting projects, include new + existing -to -remain interior lighting fixture wattage in
Proposed Lighting Wattage table in LTG-INT-BLD or LTG-INT-SPACE form.
For exterior lighting projects, include new + existing -to -remain exterior lighting fixture wattage in
Proposed Tradable and Proposed Non -Tradable Lighting Wattage tables in LTG-EXT form.
2015 Washinqton State Enerqv Code Compliance Forms for Commercial Buildinqs includinq R2, R3, R4 over 3 stories and all R1 Revised Nov 2017
Project Title: Kahlo'sCantina
Date 4/15/2019
Change of Space Use
❑ Existing interior lighting systems in areas under -going a change in space use are upgraded to
comply with LPAs for the new space types per Tables C405.4.2(1) or C405.4.2(2).
Identify interior spaces requiring LPD upgrade to the current Code in Proposed Lighting Wattage table in
LTG-INT-BLD or LTG-INT-SPACE form.
Interior and Exterior
Lighting Power
Interior lighting
Parking garage
Exterior lighting
50% or more of existing are replaced
❑�
❑
❑�
Lighting Alterations
Select all Lighting Power and Lighting
Control elements that apply to the scope
Less than 50% of existing are replaced
❑
❑
❑
of the retrofit project. If project includes a
combination of spaces where less than
50% of the existing fixtures are replaced
Lamp and/or ballast replacement only —
existing total wattage not increased
❑
El
❑
in some spaces, and 50% or more of the
fixtures are replaced in others, then
provide separate lighting power
compliance forms for the two retrofit
conditions. Spaces undergoing the same
type of retrofit may be combined into one
lighting power compliance form.
50% or more replaced - Total lighting power of new + existing -to -remain fixtures shall comply with total
LPA per Sections C405.4.2 and C405.5.2. Include new + existing -to -remain fixtures in Proposed
Lighting Wattage table in LTG-INT-BLD, LTG-INT-SPACE or LTG-EXT form.
Less than 50% replaced - Total lighting power of new + existing -to -remain fixtures shall not exceed the
total lighting power prior to alteration. Include new + existing -to -remain fixtures in the Proposed Lighting
Wattage table in LTG-INT-BLD, LTG-INT-SPACE or LTG-EXT form.
50% threshold applies to number of luminaires for interior spaces and parking garages, and total
Refer to Section C503.6 for additional
installed wattage for exterior luminaires.
requirements.
Lighting Controls
Interior lighting
Parking garage
Exterior lighting
All alteration lighting controls shall be
commissioned per C408.3.
New wiring installed to serve added
fixtures and/or fixtures relocated to new
❑�
❑
2
circuit(s)
New or moved lighting panel
❑
❑
❑
Interior space is reconfigured -
luminaires unchanged or relocated only
❑
New wiring or circuit - For interior lighting, provide required manual controls per C405.2.3, occupancy
sensor controls per C405.2.1, daylight responsive controls per C405.2.4 and application specific lighting
❑ No changes are being made to
the interior or exterior lighting
systems and existing space
controls per C405.2.5. For exterior lighting, provide required controls per C405.2.7.
New or moved panel - Provide all applicable lighting controls as noted for New Wiring and automatic
time switch controls per C405.2.2.
uses and configuration are not
Reconfigured interior space - Provide all required lighting controls that apply to a new interior space.
changed.
Application specific lighting control provisions per C405.2.5 do not apply to reconfigured spaces.