MAG-code-Analysis 01 Dec 2016.pdfStrotkamp A,E,!:hjtects IE�.O. 11130X 01 1113urfin ton W.A 98233 Code Analysis To: FILE Sq. From: Strotkamp Architects S-1 Parts 1,648 Sq. ft. 1/300 6 Sub -total 9,290 David Estes ft. Date: 01 December 2016 Total 47,020 Sq. ft. (206)-979-8320 Email: dhestes_aia@frontier.com Re: Magic Toyota CC: File Area summary Building Area/Use Area Occupant Load Occupants S-1 Occupancy Main Floor Tech support 3,753 Sq. ft. 1/100 38 Service 8,900 Sq. ft. 1/300 30 Check-in 9,666 Sq. ft. 1/300 34 Quick Lube 2,900 Sq. ft. 1/300 10 New Car Delivery 1,475 Sq. ft. 1/100 15 Parts 1,040 Sq. ft. 1/100 4 Sub -total 27,734 Sq. ft. 131 B Occupancy Administration 4,200 Sq. ft. 1/100 42 Display/Sales 5,796 Sq. ft. 1/100 58 Sub -total 9,996 Sq. ft. 100 Upper Floor B Office/Admin 7,642 Sq. ft. 1/100 76 S-1 Parts 1,648 Sq. ft. 1/300 6 Sub -total 9,290 Sq. ft. 82 Total 47,020 Sq. ft. 313 Magic Toyota Code Analysis O1 December 2016 Page: 2 Occupancy Mixed Occupancy B and S-1 For allowable area the more restrictive governs B= 23,000 sq. ft. S-1 = 17,500 sq ft Allowable area (Basic) 17,500 sq. ft. Area increase (Max 75%) 13,125 sq. ft. Total allowable per story 30,625 sq. ft. Area Increase for Fire sprinkler system (200 % for 2 story building) 35,000 sq. ft. Allowable Floor Area w/ Sprinkler 52,500 sq. ft. Building area as proposed Main Floor 37,730 sq. ft. Upper Floor 9,290 sq. ft. New Canopy 400 sq. ft Total 47,420 sq. ft. The Building area as designed requires area increase for fire sprinkler system for area increase. Area Increased 75% maximum based on formula If = [F/P-.25]W/30 If = area increase due to frontage F= building perimeter that fronts on public way or open space greater than 20' P = building perimeter W width of public way per section 506.2.1 In the case of a varying W the width shall be weighted when the width is less than 20 ft for a section Code Analysis 2015 International Building Code Section Description Project Impact 304.1 Occupancy Group B business Motor vehicle showrooms are in this occupancy Magic Toyota Code Analysis O1 December 2016 Page: 3 311.1 Occupancy Group S-1 motor Motor Vehicle repair garages fall under this occupancy vehicle repair garages complying with limits on hazardous materials 406.6 Motor Vehicle -related Defines that mixed use facilities shall comply with Occupancies — repair garages section 508.1 (mixed use occupancies) 406.6.6.2 Gas Detection System Requirements for vehicles that may be repaired fueled by non odorized gases (at this point that would be hydrogen or LNG) — doesn't appear to apply 414 Hazardous materials storage Criteria for reporting and determining the allowable and use amounts of hazardous materials to be stored ( has not be an impact on past projects) 416 Application of Flammable finishes 502.1 Defines building area as the enclosed area surrounded by exterior walls and areas of the building not provided with surrounding walls shall be included if such areas are within the horizontal project of the roof or story above 503 Allowable areas and heights Table 503 per construction type Would apply if there was a paint booth or painting in the facility ( Does not Apply) Requires that the area under the canopy be included in the building area. See Above, 504 Building Height 2 stories allowed under S-1 (most restrictive ) occupancy 505 Mezzanines No mezzanines by definition second story. 506 Building area Modifications See above , General the project meets the criteria for an area increase 506.2 Requirements for frontage Full percentage allowed, all portions measure at least increase 20' to the center line of the public right of way 506.3 Automatic Sprinkler system Allowed as building is sprinklered area increase Magic Toyota Code Analysis O1 December 2016 Page: 4 508 Mixed occupancy Defines criteria for mixed occupancies and requirements for accessories defines that there is no separation required between B and S-1 occupancies. 602 Construction type For II -B construction requires 2 hour construction at Table 601 Classification and fire exterior bearing walls except as modified by table 602 resistive requirements which allows the fire resistance of exterior walls to decrease to 0 for distances greater than 30' and 1 hour greater than 10' but less than 602.2 Type II Construction Defines construction type II as having exterior walls of non combustible construction. 705.11 Parapets Defines requirements for parapets at exterior walls and at fire walls — not required this project 907.2 Where Required Section 907.2.2 does not require a fire alarm system in group B occupancies nor are there requirements for alarm systems in S-1 Occupancies. However, the system was part of the permitting requirement on the project. As such it must be installed according to the code. 907.3 Fire Safety Functions Defines requirements for fire detectors which shall be connected to 907.3.1 Duct some detectors Connected to the alarm system 907.4 Initiating devices Locations of pull stations located not more the 5' from an exit. (required exit not every exterior door), maximum travel distance 200' 907.4.3 Automatic smoke detection When an automatic smoke detection system is required it shall utilize smoke detectors. In spaces where smoke detectors cannot be used because of ambient conditions, approved automatic heat detectors shall be permitted. 907.5 Occupant notification Required for automatic fire detectors and manual fire systems alarm boxes on this project. 907.5.2.1 Audible Alarms Required 907.5.2.2.5 Emergency Power Required Magic Toyota Code Analysis 01 December 2016 Page: 5 907.5.2.3 Visible Alarms International Fire Code 2015 Edition 503.2, 503.2.1 505.1 506 507 Appendix C 510 603.1 Specifications, Dimensions Address Identification Key boxes Fire Protection Water Supplies Not required in exists but required public and common areas. Complies with figure 550302.1 through 503.2.8 Will comply, location on highway 99 Face T.B.D. Location T.B.D. suggest adjacent to either riser room or SE corner entry Available at street, flow test have not be run estimate demand of approx... 1500 gpm for building Hydrant locations Hydrants are located along highway 99 and as part of the parking structure project in 2007 a new hydrant was installed at the SW corner of the site. Complies Emergency Responder Radio coverage Fuel Gas Appliances 607 Elevator operation, maintenance and Fire service Keys T.B.D. based on building construction and testing. Will Comply Design will comply and meet requirements of the 2015 International Mechanical Code. Elevator will be specified with emergency power required and fire service keys 903.2.9.1, Repair Garages The facility will be provided with fire protections 903.1.2.1 systems Complies 903.2.1 Sprinkler Contractor to comply as condition of permit. Exterior Exterior Access to Riser Access room 905 Standpipes 906 Portable Fire Extinguishers See floor plan sheet A-2.0 Complies Review of this section indicates that standpipes are not required. Will comply to be located as part of final building permit submittal. Magic Toyota Code Analysis O1 December 2016 Page: 6 907.2 Where Required Section 907.2.2 does not require a fire alarm system in group B occupancies nor are there requirements for alarm systems in S-1 Occupancies. However, the system was part of the permitting requirement on the project. As such it must be installed according to the code. 907.3 Fire Safety Functions Defines requirements for fire detectors which shall be connected to 907.3.1 Duct some detectors Connected to the alarm system 907.4 Initiating devices Locations of pull stations located not more the 5' from an exit. (required exit not every exterior door), maximum travel distance 200' 907.4.3 Automatic smoke When an automatic smoke detection system is detection required it shall utilize smoke detectors, In spaces where smoke detectors cannot be used because of ambient conditions, approved automatic heat detectors shall be permitted. 907.5 Occupant notification Required for automatic fire detectors and manual fire systems alarm boxes on this project. 907.5.2.1 Audible Alarms Required 907.5.2.2.5 Emergency Power Required 907.5.2.3 Visible Alarms Not required in exists but required public and common areas. 912.2 Fire Department Will comply see civil engineering drawings Connections Chapter 23 Motor Fuel Dispensing No dispensing of fuel of any kind will occur at this Facilities and Repair facility. However Class IIIB combustible liquids will garages. be dispensed in the facility. All tanks, piping and will comply. Liquid storage rooms are not required as only Class IIIB liquids are used. Chapter 57 Flammable and Will comply only Class IIIB liquids are used in the Combustible Liquids facility. Electrical lighting and mechanical systems shall comply at the oil/Compressor room. footprint Site and building plans are available for pre -incident Magic Toyota Code Analysis 01 December 2016 Page: 7 planning.