mcfarlane spec sheet.pdf74tHeri?a+r S*UA(rd, HEATING & AIR CONDITIONING Product Data Variable Speed Accul-inkTm Heat Pumps 4A6V8024A1000A 4A6V8036A1000A 4A6V8037A1000A 4A6V8048A1000A 4A6V8049A1000A 4A6V8060A1000A Note: "Graphics in this document are for representation only. Actual model may differ in appearance. " June 2017 12 -13 53-1 B- E N �"H Ingersoll Rand A*& fe W S7irff&rd, HEATING & AIR CONDITIONING Mechanical Specification Options General The Outdoor Units are charged from the factory for matched indoor section and up to 15 feet of piping. This unit is designed to operate at outdoor ambient temperatures from 55' F to 120' F in cooling and from —10' F to 66' F in heating. Only AHRI approved indoor matches are approved for use with these models. Accul-ink'" Heat Pumps This outdoor unit contains the Accul-inkT' Heat Pumps digital communication with 2 wire connection to outdoor and Plug-n-Play set up. Casing Unit casing is constructed of heavy gauge. G60 galvanized steel and painted with a weather - resistant powder paint on all louvered panels and prepaint on all other panels. Corrosion and weatherproof CMBP-G30 DuraBaseT' base. Refrigerant Controls Refrigeration system controls include condenser fan, compressor contactor and high and low pressure switches. A factory supplied, field installed filter is standard. Compressor Inverter driven scroll compressor with 25 to 100% output capacity on heat pumps and 30 to 100% output capacity on air conditioners. Noise enclosure minimizes sound levels and built in compressor protection protects compressor will reduce operating speed and current draw to maintain operation while protecting the compressor. Condenser Coil The Spine FinT11 outdoor coil provides low airflow resistance and efficient heat transfer. The coil is protected on all four sides by louvered panels. Low Ambient Cooling As manufactured, this system has built in freeze protection that will allow cooling operation below 55°F but will reduce capacity or shut down completely to prevent operation under adverse conditions. Comfort Control The 950/850 Control is required and provides Plug-n-Play setup and 3 wire connection. 12-1353-1 B-E N Amw?Ao S?�wdwd HEATING & AIR CONDITIONING Product Specifications HEAT PUMP MODELS OUTDOOR UNIT (a) (b) 4A6V8024A1000B 4A6V8036A1000B 4A6V8037A1000B POWER CONNS. — V/PH/HZ (0 208/230/l/60 208/230/l/60 208/230/l/60 MIN. BRCH. CIR. AMPACITY 17.0 25.0 26.0 BR. CIR. PROT. RTG. — MAX. (AMPS) 25 35 40 COMPRESSOR SCROLL SCROLL SCROLL NO. USED — NO. SPEEDS 1-VARIABLE 1-VARIABLE 1-VARIABLE R.L. AMPS (d) — L.R. AMPS 11.5 — 10.2 18.1 — 10.2 18.4 — 10.2 FACTORY INSTALLED START COMPONENTS (e) NA NA NA INSULATION/SOUND BLANKET YES YES YES COMPRESSOR HEAT YES YES YES OUTDOORFAN DIA. (IN.) — NO. USED 23 — 1 23 — 1 27.5 — 1 TYPE DRIVE — NO. SPEEDS DIRECT— VARIABLE DIRECT— VARIABLE DIRECT —VARIABLE CFM @ 0.0IN. W.G.M 2680 2850 3670 NO. MOTORS — HP 1-1/3 1-1/3 1-1/3 MOTOR SPEED R.P.M. 200 — 1200 200 — 1200 200 — 1200 VOLTS/PH/HZ 208/230/l/60 208/230/l/60 208/230/l/60 F.L. AMPS 2.8 2.8 2.8 OUTDOOR COIL — TYPE SPINE FINTm SPINE FIN"" SPINE FINTM ROWS—F.P.I. 1-24 1-24 1-24 FACE AREA (SQ. FT.) 19.77 23.75 27.87 TUBE SIZE (IN.) 3/8 3/8 3/8 REFRIGERANT R410-A R410-A R410-A LBS. — R-410A (O.D. UNIT) (g) 7 Ib — 6 oz 8 Ib - 3 oz 9 lb — 8 oz FACTORY SUPPLIED YES YES YES LINE SIZE — IN. O.D. GAS (h) 5/8 3/4 3/4 LINE SIZE — IN. O.D. LIQ. (h) 3/8 3/8 3/8 CHARGING SPECIFICATIONS SUBCOOLING l0o l0o go DIMENSIONS HXWXD HXWXD HXWXD CRATED (IN.) 46 X 30.1 X 33 46 X 30.1 X 33 46.4 x 35.1 x 38.7 WEIGHT SHIPPING (LBS.) 225 238 263 NET (LBS.) 204 217 238 (a) Certified in accordance with the Air -Source Unitary Air -conditioner Equipment certification program, which is based on AHRI standard 210/240. (b) Rated in accordance with AHRI standard 270/275. (c) Calculated in accordance with Natl. Elec. Codes. Use only HACR circuit breakers orfuses. (d) This value shown for compressor RLA on the unit nameplate and on this specification sheet is used to compute minimum branch circuit ampacity and max. fuse size. The value shown is the branch circuit selection current. M No means no start components. Yes means quick start kit components. PTC means positive temperature coefficient starter. (f) Standard Air — Dry Coil — Outdoor (g) This value approximate. For more precise value see unit nameplate. (h) Max. linear length 150 ft.; Max. lift— Suction 50 ft.; Max. lift — Liquid 50 ft.. 12-1353-1 B-EN 4mwcoo S7�todm d HEATING & AIR CONDITIONING Product Specifications HEAT PUMP MODELS CONT. OUTDOOR UNIT (a) (b) 4A6V8048A1000B 4A6V8049A1000B 4A6V8060A1000B POWER CONNS. — V/PH/HZ M 208/230/1/60 208/230/1/60 208/230/1/60 MIN. BRCH. CIR. AMPACITY 28.0 29.0 37.0 BR. CIR. PROT. RTG. — MAX. (AMPS) 40 45 50 COMPRESSOR SCROLL SCROLL SCROLL NO. USED — NO. SPEEDS 1-VARIABLE 1-VARIABLE 1-VARIABLE R.L. AMPS (d) — L.R. AMPS 20.3 — 12.0 21.1 — 12.0 27.5 — 12.0 FACTORY INSTALLED START COMPONENTS (e) NA NA NA INSULATION/SOUND BLANKET YES YES YES COMPRESSOR HEAT YES YES YES OUTDOORFAN DIA. (IN.) — NO. USED 27.5 — 1 27.5 — 1 27.5 — 1 TYPE DRIVE — NO. SPEEDS DIRECT— VARIABLE DIRECT —VARIABLE DIRECT— VARIABLE CFM @ 0.0IN. W.G.M 4467 4517 4757 NO. MOTORS — HP 1-1/3 1-1/3 1-1/3 MOTOR SPEED R.P.M. 200 — 1200 200 — 1200 200 — 1200 VOLTS/PH/HZ 208/230/1/60 208/230/1/60 208/230/1/60 F.L. AMPS 2.8 2.8 2.8 OUTDOOR COIL — TYPE SPINE FINTM SPINE FINTN SPINE FINTM ROWS—F.P.I. 1-24 1-24 1-24 FACE AREA (SQ. FT.) 27.87 27.87 30.80 TUBE SIZE (IN.) 3/8 3/8 3/8 REFRIGERANT R410-A R410-A R410-A LBS. — R-410A (0.D. UNIT) (9) 9 lb — 13 oz 10 Ib — 12 oz 11 Ib — 14 oz FACTORY SUPPLIED YES YES YES LINE SIZE — IN. O.D. GAS 7/8 (h) 7/8 (h) 1 - 1/8 (1) LINE SIZE — IN. O.D. LIQ. (h) 3/8 3/8 3/8 CHARGING SPECIFICATIONS SUBCOOLING SO° 10° 10° DIMENSIONS HXWXD HXWXD HXWXD CRATED (IN.) 46.4 x 35.1 x 38.7 46.4 x 35.1 x 38.7 51 X 35.1 X 38.7 WEIGHT SHIPPING (LBS.) 268 275 285 NET (LBS.) 243 250 259 (al Certified in accordance with the Air -Source Unitary Air -conditioner Equipment certification program, which is based on AHRI standard 210/240. (b) Rated in accordance with AHRI standard 270/275. (0 Calculated in accordance with Natl. Elec. Codes. Use only HACR circuit breakers orfuses. (d) This value shown for compressor RLA on the unit nameplate and on this specification sheet is used to compute minimum branch circuit ampacity and max. fuse size. The value shown is the branch circuit selection current. (e) No means no start components. Yes means quick start kit components. PTC means positive temperature coefficient starter. (fl Standard Air — Dry Coil — Outdoor (9) This value approximate. For more precise value see unit nameplate. (h) Max. linear length 150 ft.; Max. lift— Suction 50 ft.; Max. lift — Liquid 50 ft. (0 Max length of refrigerant lines from outdoor to indoor unit MUST NOTexceed 80 feet. The max vertical change MUST NOTexceed 10 feet. See footnote (h) if 7/8" suction line is used. 12-1353-1 B-EN A*& fe W S7irffdard, HEATING & AIR CONDITIONING Sound Data Model Mode Speed A -Weighted Sound Power Level[dB(A)] Full Octave Sound Power [dB] 63 125 250 500 1000 2000 4000 8000 Hz Hz Hz Hz Hz Hz Hz Hz 4A6V8024A Cool Min 54 70.9 50.3 51.8 52.3 50.4 42.0 37.7 39.9 Cool Max 65 76.3 65.2 62.7 64.1 60.5 55.7 49.5 45.0 Heat Min 60 69.8 52.9 52.8 57.5 55.2 51.9 47.4 46.5 Heat Max 69 75.9 66.0 64.7 67.3 65.6 57.0 52.2 47.7 4A6V8036A Cool Min 56 71.5 51.5 54.7 54.4 52.2 43.1 36.8 38.5 Cool Max 70 74.1 69.4 65.9 70.5 65.1 59.4 54.2 49.5 Heat Min 60 68.3 52.1 53.9 57.6 55.1 52.9 45.1 47.8 Heat Max 74 78.7 70.3 76.3 73.0 68.7 61.1 57.3 53.6 4A6V8037A Cool Min 56 71.5 51.5 54.7 54.4 52.2 43.1 36.8 38.5 Cool Max 70 74.1 69.4 65.9 70.5 65.1 59.4 54.2 49.5 Heat Min 60 68.3 52.1 53.9 57.6 55.1 52.9 45.1 47.8 Heat Max 74 78.7 70.3 76.3 73.0 68.7 61.1 57.3 53.6 4A6V8048A Cool Min 61 70.6 55.0 55.9 55.8 59.0 49.9 41.1 42.9 Cool Max 74 75.7 71.9 73.0 74.2 68.5 63.4 59.1 54.3 Heat Min 62 72.1 59.3 58.7 60.3 58.6 51.3 46.0 45.2 Heat Max 76 77.9 74.5 77.0 75.4 69.5 64.4 60.8 56.2 4A6V8049A Cool Min 61 70.6 55.0 55.9 55.8 59.0 49.9 41.1 42.9 Cool Max 74 75.7 71.9 73.0 74.2 68.5 63.4 59.1 54.3 Heat Min 62 72.1 59.3 58.7 60.3 58.6 51.3 46.0 45.2 Heat Max 76 77.9 74.5 77.0 75.4 69.5 64.4 60.8 56.2 4A6V8060A Cool Min 57 69.7 59.5 57.6 55.1 52.0 45.0 41.6 42.3 Cool Max 73 83.9 73.7 73.1 71.2 67.9 64.4 58.9 51.8 Heat Min 61 71.9 61.3 59.0 61.3 56.2 48.7 45.1 45.5 Heat Max 74 85.8 75.7 74.4 73.2 68.5 63.6 59.6 55.9 4A6V8060A Cool Min 57 69.7 59.5 57.6 55.1 52.0 45.0 41.6 42.3 Cool Max 73 83.9 73.7 73.1 71.2 67.9 64.4 58.9 51.8 Heat Min 61 71.9 61.3 59.0 61.3 56.2 48.7 45.1 45.5 Heat Max 74 85.8 75.7 74.4 73.2 68.5 63.6 59.6 55.9 NOTE: Rated in accordance with AHRI Standard 270 12-1353-1 B-EN 4ticmr oo S7it idard HEATING & AIR CONDITIONING Sound Data Model Mode Speed Sound Pressure in [dB] at 3' at 5' at 10' at 15' Cool Min 47 42 36 33 Cool Max 58 53 47 44 4A6V8024A Heat Min 53 48 42 39 Heat Max 62 57 51 48 Cool Min 49 44 38 35 Cool Max 63 58 52 49 4A6V8036A Heat Min 53 48 42 39 Heat Max 67 62 56 53 Cool Min 49 44 38 35 Cool Max 63 58 52 49 4A6V8037A Heat Min 53 48 42 39 Heat Max 67 62 56 53 Cool Min 54 49 43 40 Cool Max 67 62 56 53 4A6V8048A Heat Min 55 50 44 41 Heat Max 69 64 58 55 Cool Min 54 49 43 40 Cool Max 67 62 56 53 4A6V8049A Heat Min 55 50 44 41 Heat Max 69 64 58 55 Cool Min 50 45 39 36 Cool Max 66 61 55 52 4A6V8060A Heat Min 54 49 43 40 Heat Max 67 62 56 53 NOTE: Rated in accordance with AHRI Standard 275 12-1353-1 B-EN A*& fe W S7irffdard, HEATING & AIR CONDITIONING Optional Accessories: Model 4A6V8024A 4A6V8036A 4A6V8037A 4A6V8048A 4A6V8049A 4A6V8060A Rubber Isolator Kit BAYISLT101 BAYISLT101 BAYISLT101 BAYISLT101 BAYISLT101 BAYISLT101 Snow Leg —Base & Cap 4"High BAYLEGS002 BAYLEG2002 BAYLEGS002 BAYLEGS002 BAYLEGS002 BAYLEGS002 Snow Leg — 4" BAYLEGS003 BAYLEGS003 BAYLEGS003 BAYLEGS003 BAYLEGS003 BAYLEGS003 Extension Extreme Condition Mounting Kit BAYECMT023 BAYECMT023 BAYECMT004 BAYECMT004 BAYECMT004 BAYECMT004 Refrigerant Lineset TAYREFLN90) TAYREFLN70) TAYREFLN7(a) TAYREFLN30) TAYREFLN30) TAYREFLN3(a) M Consult handbook for available length options. General Data AHRI STANDARD 210/240 RATING CONDITIONS • Cooling 80°F DB, 67°F WB air entering indoor coil, 95°F DB air entering outdoor coil. • High Temperature Heating 47°F DB, 43°F WB air entering outdoor coil, 70°F DB entering indoor coil. • Low Temperature Heating 17°F DB, 15°F WB air entering outdoor coil, 70°F DB air entering indoor coil. • Rated indoor airflow for heating is the same as for cooling. AHRI STANDARD 270 RATING CONDITIONS — (Noise rating numbers are determined with the unit in cooling operation) Standard Noise Rating number is at 95°F outdoor air. 12-1353-1 B-EN Amw?Ao S?�wdwd HEATING & AIR CONDITIONING Model Nomenclature Outdoor Units a A 6 v Refrigerant Type 2 = R-22 4 = R-410A A,T = American Standard ProductType 6, W = Split Heat Pump 7T = Split Cooling Product Family V=Variable Speed Mor B=Basic Z=Leadership -Two Stage A= Light Commercial X = Leadership R = Replacement/Retail Family SEER - 3-13 6-16 4=14 8=18 5=15 9=19 0=20 Split System Connections 1-6Tons 0 = Brazed Nominal Capacity in 1000s of BTU'. Major Design Modifications — Power Supply 1 = 200-230/1/60 or 208-230/1/60 3 = 200-230/3/60 4 = 460/3/60 Secondary Function Minor Design Modifications — Unit Parts Identifier 1 2 3 4 ! Gas Furnaces AU H I E I Furnace Configuration AU= Upflow/Horizontal AD= Downflow/Horizontal Type E = 80% Induced Draft Standard D = 80 % Induced Draft Premium C = 90% Condensing Standard X = 90 % Condensing Premium H = 95% Condensing Premium Number of Heating Stages 1 = Single Stage 2 =Two Stage 3 =Three Stage M = Modulating r=tii=oe Uri— A=14.5" Cabinet Width B = 17.5" Cabinet Width C = 21.0" Cabinet Width D = 24.5" Cabinet Width Heating Input in 1000's (BTUH) 080 = 80,000 BTUH Major Design Change 5 6 7 8 9 10 1112 13 14 15 0 0 3 6 A 1 0 0 0 A A 6 7 8 9 10 11121314 16 9 = 115 Volts / 60 Hertz / Natural Gas A =115 Volts / 50 Hertz / Natural Gas C = 115 Volts / Natural Gas with Communicating System Control F = 115 Volts / Natural Gas with Integrated Electronic Filter D = 115 Volts / Natural Gas with Communicating System Control and Integrated Electronic Filter Air Capacity for Cooling Standard PSC Variable Speed High Efficiency 24-2Tons V3=3 Tons H3=3 Tons 36=3Ton s V4=4Tons H4=4Tons 42=3.5 Tons V5=5Tons H5=5Tons 45=4Tons 48=4Tons 54=5Tons 60=5Tons 72=6Tons Draft Inducer Speed: 1 =Single Speed 2 = Two Speed V = Variable Speed Minor Design Chang Service Digit- Not Orderable Air Handler 1 2 3 a TAM 8 Brand T = American Standard G = Good (American Standard Branded) Product Type A= Air Handler Convertibility M = Multi -poise 4-way F = Upflow Front Return, 3-way T = 3-way P—A .It Ti., 5 6 7 8 9 10111213 14 15 2 = Good, Entry Level Feature Set 4 = Better, Retail Replacement Mid Effy 5 = Better, Entry Levek High Effy, Multi -Speed 7 = Best, Retail Replacement High Effy, Variable Speed 8 = Best, Retail Ultimate High Effy, Variable Speed Major Design Change No Descriptor 0 = Air Handier / Coil Size (Footprint) A = 17.5 x 21.5 B - 21.0 x 21.5 C = 23.5 x 21.5 Cooling Size: Air Handler or Coil 0-9 = AH Coil - 1000 BTUb (18, 24, 30, 36, 42, 48, 60) AirflowType & Capability S = Low Effy PSC, 1-5-nom.,Tonnage (cfm/ton) M = Mid Effy Multi -Speed, 1-5- nom.,Tonnage (cfmRon) H = High Effy Multi -Speed, 1-5 - nom.,Tonnage (cfm/ton) V = High EffyVariable, 1-5 - nom.,Tonnage (cfm/ton) Power Supply 1 - 208-230/1160 System ControlType S - Standard - 24 VAC C=CLII 13.8 VDC Minor Design Change Unit Parts Identifier Heat Pump/ a r z1 Cooling Coils Refrigerant Type 4 = R-410A Series T = Premium (Heat Pump N = Premium (Convertible to HP) C = Standard Coil Design X = Direct Expansion Evaporator Coil Coil Feature C = Case A Coil A= Uncased A Coil F = Cased Horizontal Flat Coil Coil Width (Cased/Uncased) A - 14.5"A 3.3" B = 175"/16.3" C = 21.0"/19.8" D = 24.5"/23.3" H = 10.5" Refrigerant Ulne Coupling 0 = Brazed Nominal Capacity in 1000's (BTUH) 4 5 6 7 8 9 10 111213 14 15 Major Design Change Efficiency C = Standard S = Hi Efficiency (Derived from 10 SEER products) Refrigerant Control 3 =TXV - Non -Bleed Coil Circuitry H = Heat Pump C=Cooling Airflow Configuration A= Upflow Only U = Upflow/Downflow H = Horizontal Only C = Convertible - Upflow, Downflow, Left or Right Upflow Minor Design Change Service Digit - Not Orderable 12-1353-1 B-EN N LEGEND 21 V FACTWY POL. PLW FEMALE HW91X6 MM ..........� LIXf V WIRING LIKE y) FIELD WIRING [MALE TERMI NALSI '®' fFENALEUTERM NA1 MILE LS j31X6 ricFEW .. WS BN/BL �ORm � MAGNETIC COIL u.r[I eCHASSIS EARTH GROUND EARTH ORWMD IL L vl[ PN PINS. M DLA� PuRP INS - COIL ROTTON SENSOR • 0 jUN ION YIRE NUl OR TERMINAL IRA - COMN DISPLAY ASSEMBLY VS CPR - YAR IAYLF SPEED CgIPAE950R O TN[PN IGTOR EEV_ INTERNAL OVERLOAD PROTECTION W, S. oUSUCTOIOXEPR[SSYAEETRAMSDNER �-O SC/L30V - SNITCH OVER VALVE WLENOID PRESSURE ACTUATED SNITCHLl RESISTER OR NEATI NG ELEMENT _ LATEO COX: `"`- CP"b MOTOR WINDING DT._DO lE.ATUN 9EX WR CIL COMYURINATION LINK PSC - PERMAA.ENENT SPLIT CAP.-1 NOIOR CONL SHIELDED CABLE LS LOAD SHED 010 NOTES: I. BE SURE POWER SUPPLY AGREES WITH EQUIPMENT NAMEPLATE. 1. POWER WIRING AND GROUNDING OF EQUIPMENT MUST COMPLY WITH LOCAL CODES. 3. LOW VOLTAGE WIRING TO BE NO. IB AWG MINIMUM CONDUCTOR. 4.. ONLY USED ON HEAT PUMP MODELS AND NOT ON AC UNITS FOR CANADIAN INSTALLATIONS POUR INSTALLATIONS —DIENNE9 CAUTION: NOT SUITABLE TON USE ON LISTENS ETC[EDI X4 ID-RO.ORWND LA IEN.E ®WARNING [L Fa ilur.A. O i x....s l P In9 <a ere re SA I'll �J �rY or aulAR< mCAUTION TO A m 0 k6V8024A1 2 Ton Heat Capacity Balance Point Worksheet 35 30 25 20 15 10 5 0 W M z2 7 12 17 22 27 32 37 42 47 52 57 62 67 72 Outdoor Temperature (F) Based on 70F Indoor Return Air +Max Capacity -a-Min Capacity N W U W W r!n Z 45 40 35 30 25 20 15 10 5 0 3 Ton Heat Capacity Balance Point Worksheet 2 7 12 17 22 27 32 37 42 47 52 57 62 67 72 Outdoor Temperature (F) Based on 70F Indoor Return Air Max Capacity Min Capacity N •A6V8037A1 3 Ton Heat Capacity Balance Point Worksheet 45 40 35 r- 30 25 20 15 10 5 N W Z 2 7 12 17 22 27 32 37 42 47 52 57 62 67 72 Outdoor Temperature (F) Based on 70F Indoor Return Air Max Capacity Min Capacity N W U W W r!n Z 70 60 50 C 3 40 �o 30 20 10 0 W 4 Ton Heat Capacity Balance Point Worksheet 2 7 12 17 22 27 32 37 42 47 52 57 62 67 72 Outdoor Temperature (F) Based on 70F Indoor Return Air Max Capacity -m-Min Capacity •A6V8049A1 4 Ton Heat Capacity Balance Point Worksheet 70 60 50 C 3 40 �o 30 20 10 r W m z 2 7 12 17 22 27 32 37 42 47 52 57 62 67 72 Outdoor Temperature (F) Based on 70F Indoor Return Air Max Capacity -m-Min Capacity u U�:11I117A 60 50 C 40 30 20 10 0 5 Ton Heat Capacity Balance Point Worksheet 2 7 12 17 22 27 32 37 42 47 52 57 62 67 72 Outdoor Temperature (F) Based on 70F Indoor Return Air -*-Max Capacity -m-Min Capacity qJAPIngersoil Rand, Ingersoll Rand (NYSE: IR) advances the quality of life by creating comfortable, sustainable and efficient environments. Our people and our family of brands — including Club CaO, Ingersoll Rand(D, Thermo King® and TraneD—work together to enhance the quality and comfort of air in homes and buildings; transport and protect food and perishables; and increase industrial productivity and efficiency. We are a global business committed to a world of sustainable progress and enduring results. �® ("J? Ingersoll Rand T THERMO KING 0 TRANE' ingersollrand.com C ETI US Intertek Ingersoll Rand has a policy of continuous product and product data improvements and reserves the right to change design and specifications without notice. We are committed to using environmentally conscious print practices. 12-1353-1 B-EN 05 Jun 2017 Supersedes 12-1353-1A-EN (January2014) ©2017Ingersoll Rand