Loading...
mech ventilation.pdfWALLS CEILING ROOM DESCRIPTION FLOOR BASE MATERIAL FINISH COLOR HT. MATERIAL FINISH COLOR 00 CD z 00 00 O Q N � Q] W CD yJ W J Z co Q ( Q W W > O ¢ O Z W W O _ z 0 <..) f OLU J J W _UJ Cn ¢ W Cn ¢ ¢ W W U}JW UHw N WO W W J W j WO UJ co Mn n WW _ �o O zw w a m J i) w O N � w O J W } < zw W n Z MQQ Z z (D z Q x n zW f- O n J J _ ' > ¢ W -W- w Jw ¢ CO n Lu � LL W F_ _J J ¢ ¢ � U) W Cr) ...I= mU CO z ¢H U)H H w U U cn 7 pa O ¢Q ¢ LW OH aQ U U¢ J ¢ Z z _ OcLLJ W OZ O nz gFY Q Q F- J of � H H F J U) U O Q W U m coO O W W Lli n O J I- O W Z x O aaO O z 0 O O x NAME W c x ¢ n U x � Q Q �M w ¢ LLJF- Dg �x cn n a O OROOM z Oz zw cc CD io i0 � zo io n Ln Ln cn a LL n U) cn z CD n Ln co EN C0 w W ¢U LL- co a � Q_ 101 BREAD DISPLAY AREA • • • • • • • • • 102 SALES AREA • • • • • • • • • • • • 103 SERVICE AREA • • • • • • • • • • 104 WOMEN'S RESTROOM • • • • • • • • • 105 MEWS RESTROOM • • • • • • • • • 106 KITCHEN AREA • • • • • • • • 107 WALK-IN COOLER • • • • • • • 108 WALK-IN FREEZER • • •4- • • • • NOTE: QUARRY TILE FLOOR UNDER EQUIPMENT HAS TO BE SMOOTH. O QUARRY TILE BASE SHALL BE 6' W/ 3/8' COVE RADIUS BY DAL -TILE O CERAMIC TILE BASE SHALL BE 6- W/ 3/8' COVE. O CLASS A PER ASTM E-84 O CLASS 'A' RRE-RATED CEILING PANEL. O PAINT FINISH !N THE RESTROOM, KITCHEN AND DRY FOOD STORAGE WILL BE SEMI -GLOSS PAINT FINISH DOOR SCHEDULE NO. DESCRIPTION MFG SIZE FRAME THK CORE TYPE FACE/EDGE HARDWARE REMARKS D1 (N) MAIN EXIT DOUBLE -DOOR MATCH EXIST'G T-0" X T-O" (PAIR) ALUM 2" ALUM D2 PULLS/NEW PANIC BY GC SELF -CLOSING/ BY GC D2 (E) SIDE EXIT DOOR EXISTG 3'-0" X T-0" H. METAL 1 3/4 SOLID D6 PUSH/ PULL LEVER SELF -CLOSING/ BY GC D3 (N) SERVICE DOOR ELIASON (2)1'-6" X T-0" H. METAL 1 3/4 SOLID D1 SELF -CLOSING, NO LATCH/LEVER 10" KICK PLATE; SEE THROUGH WINDOW; DOUBLE -SWING D4 (E) STOREFRONT DOOR EXISTG T-0" X T-0" ALUM 1 3/4" ALUM D4 PULLS/NEW PANIC BY GC 10" KICK PLATE; DOUBLE -SWING D5 (N) RESTROOM DOOR CECO OR EQUAL 3'-0" X 6'-8" H. METAL 1 3/4" SOLID D5 SPECIAL SURFACE (SEE SCHED.) SELF -CLOSING, LEVER TYPE 10" KICK PLATE D6 (N) STORAGE DOOR CECO OR EQUAL V-6" X 6'-8" (PAIR) WOOD 1 314" SOLID D6 SPECIAL SURFACE (SEE SCHED.) LEVER TYPE WALL SCHEDULE INSTALLED AND FURNISHED BY. G.C. UNLESS NOTED OTHERWISE NO. DESCRIPTION W1 EXISTING WALL TO REMAIN 1.1 EXISTING 1 HR DEMISING WALL TO REMAIN NEW STOREFRONT SYSTEM TO MATCH EXISTING, GLAZING TO BE FIXED W/TEMPERED GLASS 3-5/8" 20GA. METAL STUD WALL W/ %" TYPE "X" GYP. BOARD BOTH SIDES (WATER RESISTANT ON RESTROOM SIDE) 3-5/8" 20GA. METAL STUD LOW WALL W/ %" TYPE "X" GYP. BOARD ON BOTH SIDES (SEE ARCHITECTURAL DETAILS & ELEVATIONS) IW5 %X" 4" 20GA. METAL STUD WALL W/ " TYPE " GYP. BOARD BOTH SIDES (WATER RESISTANT ON RESTROOM SIDE) 3-5/8"20GA. METAL STUD WALL FUR -OUT W/ %" TYPE "X" GYP. BOARD ON INTERIOR SIDE ONLY (WATER RESISTANT ON RESTROOM SIDE) 2-5/8" 20GA. METAL STUD WALL FUR -OUT W/ %" TYPE "X" GYP. BOARD ON INTERIOR SIDE ONLY (SEE ARCHITECTURAL DETAILS & ELEVATIONS) 5X WOOD STUD W/ %" TYPE "X" GYP. BOARD ON INTERIOR & 3/4" PLYWOOD ON THE EXTERIOR W/WIRE MESH GENEO RAL NOTES 1. CONSIDERATION WILL NOT BE GRANTED FOR ANY ALLEGED MISUNDERSTANDINGS OF THE AMOUNT OF WORK TO BE PERFORMED. TENDER OF PROPOSAL SHALL CONVEY FULL AGREEMENT TO THE ITEMS AND CONDITIONS INDICATED ON THE DRAWINGS. SHOULD THE CONTRACTOR FIND DISCREPANCIES OR OMISSIONS IN THE CONTRACT DOCUMENT OR BE IN DOUBT AS TO THE INTENT THEREOF, THE CONTRACTOR SHALL OBTAIN CLARIFICATION FROM THE ARCHITECT AND/OR THE OWNER'S REPRESENTATIVE PRIOR TO SUBMITTING HIS PROPOSAL FOR WORK. 2. T. G. C. SHALL FIELD VERIFY THE EXACT EXISTING SPACE CONDITIONS, DIMENSIONS AND COLUMN SPACING PRIOR TO CONSTRUCTION AND INFORM ARCHITECT IMMEDIATELY IF ANY DISCREPANCIES ARE FOUND BETWEEN DRAWINGS AND SITE CONDITIONS. ANY CHANGES OR REWORK DUE TO UNREPORTED DIFFERENCES SHALL BE AT T. G. C.'S EXPENSE. 3. ALL COLUMNS IN THE LEASE SPACE TO HAVE AT LEAST 1-HOUR FIRE SURROUND OR FIRE RATING AS REQUIRED BY LOCAL CODE (5/8" TYPE'X' GYP. BD. ON METAL STUD FRAMING FROM FLOOR TO DECK AND SEALED TIGHT. HEALTH DEPT. NOTES 1. ALL EQUIPMENT SHALL MEET NATIONAL SANITATION FOUNDATION DESIGN AND INSTALLATION REQUIREMENTS OR IT'S EQUIVALENT. 2. LIGHT FIXTURES IN FOOD PREPARATION, OPEN FOOD STORAGE AND UTENSIL WASHING AREAS ARE TO BE PROTECTED AGAINST BREAKAGE THROUGH THE USE OF PLASTIC SHIELDS, PLASTIC SLEEVES, SHATTER PROOF BULBS AND/OR OTHER APPROVED DEVICES. 3. PROVIDE PERMANENTLY MOUNTED SINGLE SERVICE SOAP AND TOWEL DISPENSERS AT ALL HAND WASH BASINS. 4. SEAL ALL CRACKS AND CREVICES IN COUNTERS, CABINETS, AROUND METAL FLASHING, SINK BACK SPLASHES AND AROUND PIPES AND CONDUITS WITH A NON -HARDENING SILICONE SEALANT. 5. QUARRY TILE TO BE "DAL TILE". 6. ALL WALL & DRYWALL CEILING ARE TO BE PAINTED W/ SAME PAINT AS INDICATED ON THE FINISH SCHEDULE. 7. ALL CABINETS SHALL BE LAMINATED INSIDE AND OUT. 8. CEILING IN FOOD PREPARATION/ RESTROOM TO BE SMOOTH, NON -ABSORBENT, DURABLE, LIGHT IN COLOR AND EASILY CLEANABLE. 9. ALL OPENINGS LEADING TO OUTER AREAS MUST BE TIGHT FITTING WHEREBY NO LIGHT SHALL BE SEEN WHEN DOORS ARE CLOSED, TO PREVENT ENTRANCE OF PESTS. G.C. NOTES 1. G.C. TO FIELD VERIFY EXISTING SITE CONDITION PRIOR TO BIDDING THE PROJECT. 2. G.C. TO PATCH, REPAIR & REFURBISH THE EXISTING WALL, FLOOR & CEILING FINISH AT THE KITCHEN, WASHING & STORAGE AREA AS NEEDED OR OWNER'S INSTRUCTION. FIRE NOTES 1. PROVIDE FIRE EXTINGUISHER AS REQUIRED BY FIRE DEPARTMENT FIELD INSPECTOR. 2. EVERY EXIT DOOR SHALL BE OPERABLE FROM THE INSIDE WITHOUT THE USE OF A KEY OR ANY SPECIAL KNOWLEDGE OR EFFORT. 3. EXIT LIGHTING AND SIGNS: MINIMUM 6" X 3/4" LETTERS ON CONTRASTING BACKGROUND. 4. ANY DECORATION USED SHALL BE NON-COMBUSTIBLE OR FLAME -PROOFED IN AN APPROVED MANNER, 5. THE INSTALLATION OR OPERATION OF SPECIAL FIRE EXTINGUISHER SYSTEM MUST BE CHECKED AND APPROVED BY THE FIRE DEPARTMENT PRIOR TO INSTALLATION. 6. PROVIDE OUTSIDE GAS SHUT-OFF VALVE CONSPICUOUSLY MARKED. 7. DEFERRED SUBMITTAL: 7.1. FIRE SPRINKLER DRAWINGS AND SPECIFICATIONS TO BE SUBMITTED BY A LICENSED SPRINKLER COMPANY TO THE FIRE MARSHALL, FOR REVIEW AND APPROVAL, PRIOR TO SYSTEM INSTALLATION/ ALTERATION 7.2. FIRE ALARM PLANS AND SPECIFICATIONS TO BE SUBMITTED BY A LICENSED FIRE ALARM CONTRACTOR TO THE FIRE MARSHALL, FOR REVIEW AND APPROVAL, PRIOR TO SYSTEM INSTALLATION/ ALTERATION M KEYNOTES NO. DESCRIPTION '0 PROVIDE SIGN "THIS DOOR TO REMAIN UNLOCKED WHILE THE BUILDING IS OCCUPIED". 0 PROVIDE SIGN OF INTERNATIONAL SYMBOL ACCESSIBILITY IBC 1009.8-1009.11 SEE DIET. 6 G-1.2. D TACTILE EXIT SIGN SEE DIET. 6 G-1.2. Q CAPACITY SIGN PER IBC 1004.3 Q COUNTER MILLWORK AT 34" HIGH A.F.F. Q TYPE II EXHAUST HOOD. 0 ACCESSIBLE RESTROOM SIGNAGE, SEE DETAIL 1/G-1.2. Q ACCESSIBLE SEATING ® 34" MAX. HEIGHT. SEE G-1.5 Q (E) REAR EXIT ED MENUBOARD ABOVE, BY OTHERS. 11 ELECTRICAL PANEL 12 NEW STOREFRONT DOORS. FIXED W/ TEMPERED GLASS TO MATCH EXISTING ,a LEDGE COUNTER ® 42" HIGH A.F.F. 14 (E) COLUMN TO REMAIN 15 (N STOIREFRPONT ENABLEGLAZING. FIXED W/ TEMPERED GLASS BUILDING NOTE: ALL GLAZING TO BE TEMPERED GLASS. NOTE: 1. PANEL DIVIDERS AT WP3 2. INSIDE CORNER AT WP3 TO WP2 3. FLASHING AT TOP OF BASE WP3 4. WP2 PIECE AT LENGTH OF WALL 5. ALL OTHER STAINLESS STEEL BY G.C. NOTE: THE FOLLOWING STAINLESS STEEL PROVIDED BY G.C.-INSTALLED BY G.C.: 18 GA. STAINLESS STEEL CORNER GUARD 18 GA. STAINLESS STEEL CORNER GUARD/FRAME - ALL G� AROUND PERIMETER OF OPENING - FRAME TO BE WELDED WITH MITERED CORNERS TO FORM SINGLE UNIT. C l (� 18 GA. STAINLESS STEEL WALL CAP "ALL INTERIOR DIMENSIONS ARE FINISHED TO FINISHED NOTE: "G.C. TO INSTALL MIN 3-1/2" NON-COMBUSTIBLE MINERAL FIBERGLASS BATTS SOUND INSULATION AT ALL RESTROOM PARTITIONS AND CEILINGS. WALL LEGEND - EXISTING WALL I- SERVICE COUNTER DIE WALL BY G.C. WALK-IN BOX PANEL ® NEW FULL HEIGHT PARTITION BY G.C. t�' �2-1 1 FLOOR PLAN" SCALE: 1/4"= l'-0" sF a" NORTH --- G.C. TO PROVIDE PANIC PANIC LEVER TYPE HARDWARE LEVER TYPE HARDWARE PANIC HARDWARE HARDWARE HARDWARE SEE DEf. DOOR SIGN SEE --- - 11 /T-1.5 DEf. 12/T-1.5 // J o C oo � I QO - co d F.FLR. ELIASd Dt OR D2 D3 D4 LD5 D6 DOOR)NEW SERA R S.S. KICK PLATE S.S. KICK PLATE S.S. KICK PLATE O NO $5 C Bakery Cafe 22611 76th Avenue West Space 100 Edmonds, WA 98026 910itpla co. 1725 westlake avenue n suite 210 Seattle, washington 98109 206.838.5485 p 206.713.4076 m 206.464.0700 f ksmith@smithco.org http-//www.smithco.org/ Consultant Consultant Registration Issues and Revisions Architect Registration 6294 REGISTERED ARCHITECT 1 KEITH L. SMITH 1STATE OF WASHINGTON No. Date Issues By Check 1 04.16.18 PERMIT SET KLS Project Name 85'C Bakery Cafe - USA Project Number 02016063.01 Description FLOOR PLAN Computer File A-1.0.DWG Scale AS NOTED Template 4.3 (120101) All ideas, designs, arrangements, and plans indicated or represented by this drawing are owned by and the property of Smith Co. Ilc and were created, evolved, and developed for use on and in connection with the specified project. None of such ideas, designs, arrangements or plans shall be used by or disclosed to any person, firm, or corporation for any purpose whatsoever without the written permission of smith co. t MAY 10 2013 A�InO DEVELOPwIENT SERVICES CTF CITY OF EDMONDS