Northpoint - RFI 063 - SW-4 Drag Straps at Level 2_SA.pdfSALUS
HEALTHCARE ARCHITECTURE
November 27, 2018
Leif Bjorback,
Kristin Johns
City of Edmonds, Development Services Department
121 5th Ave N
Edmonds, WA 98020
Subject: Northpoint Recovery, Remodel of Edmonds Facility
Request for adding Drag Straps at Level 2
Permit #BLD2018-0447
RE: RFI-063
To Leif Bjorback and Kristin Johns,
Venture Construction will be meeting with either Milton Thompson or Eric Carter to review
attached new detail #12/SKS-10 and Elevation-4 for the second floor drag straps.
The drag struts occur along Gridline-3 at the north and south sides, see attached partial plan
for locations.
In the original design, the hold downs were on the underside of the soffit and exposed to the
exterior. Instead, drag straps were added on top of the second -floor plywood (which will be
covered by flooring material)
We are requesting one of the site inspectors approve this detail.
Thank you for your consideration.
Douglas McNutt
Principal — Salus Architecture
Encl: Structural Detail #12/SKS-10, Elevation-4 and Partial Structural Floor Plan S-102
C: R. David Frum, FAIA, ACHA
ZA16029 Northpoint Recovery\Docs\06.01-MunicipalReview\AFTER PERMIT ISSUED Request for Clarification to City_10-24-18\RFI-063 SW-4 Drag Struts at Level
2\Northpoint - SW-4 Drag Straps at Level 2.docx
1402 Third Ave, Suite 200 / Seattle, WA 98101 / T 206.652.0722 / F 206.340.2266 / www.salus.archi
Mr. Leif Bjorback,
November 27, 2018
Page 2
Original Details on 4/S-221 Shear Wall Elevations that is cart of the
permit set:
Drawing sheet S-102 calls for tea locations of continuous 8"x16" drag strut with 2-HDU11
just west GL-3 & GL-6 at Level 2. These drag struts are shown to terminate at GL-A & GL-
J. Terminating these drag struts at these two identified grid lines would expose the hold
downs below the Level 2 exterior soffit area.
A B C
8' 2'-4'' 15'-8"
DRAG STRAP 3
;W9
G H J
2'_8" 2'_A$
ROOF-RIDG�
24' - 7 3/4"
' R F
23' - 10"
3
2-HDU11
LEVEL
12'-0"
Mr. LeifEjorback,
Novernber27,2[q8
Page
Revised Details on 4/S-221 Shear Wall Elevations and New Detail 12/S-
| Wood Framing Details:
Attached detail #12/SK3'10and E|evaton'4show drag strut hold-downs relocated inside the
exterior wall with steel straps at each end - above the second level plywood. Partial
Structural Floor Plan S-102 locates the detail. This has been signed by Greg Lee (ABKJ
structural engineer ofrecord).
__---------------
W�tILA N�
0IM Ji
W W-
LL N _ W
N co
O Q 0
n
Q
ry
U)
ry
Z
O
Q
w
J
W
ABKJ I
Andersen Bjornstad Kane Jacobs
Consulting Civil and Structural Engineers
1402 Third Avenue, Suite 200 1 Seattle, Washington 98101
206.340.2255 phone 1206.340.2266 fax
www.abkj.com
Northpoint
RecoverT I
y
RFI #063 RESPONSE
Partial Elevation-4/S-221
Project number 18003.00
S KS-09
Date 11/21/18
Drawn by
Checked by GJL
Scale NONE
►�OORY r L-K
E) PLWD DECK
E) TJI JST
16 GA x 1 1/4" W DRAG
STRAP
PROVIDE WEB STIFF TO
MATCH TJI FLG THK
8x16 DRAG STRUT BLKG
NOTES:
DRAG STRAP NAILING TO BE 20-10d @ 1 AVE OC AT EACH END OF THE
DRAG STRAP, WITH MAX 12" SPACING IN BETWEEN.
12
SW-4 LEVEL 2 DRAG STRAP
RFI #063 RESPONSE
ABKJ1 Northpoint New Detail 12/S-582
Andersen Bjornstad Kane Jacobs Project number 18003.00
Consulting Civil and Structural Engineers Recovery T I Date 11 /21 /18 S KS — 1 0
1402 Third Avenue, Suite 200 � Seattle, Washington 98101
206.340.2255 phone 206.340.2266 fax Drawn by
www.abkj.com
Checked by GJL Scale NONE