Loading...
Northstream Ln - 831_BLD20071046.pdf City of Edmonds TH 121 5 AVENUE NORTH • EDMONDS, WA 98020 • (425) 771-0220 FAX(425) 771-0221 Website: www.ci.edmonds.wa.us DEVELOPMENT SERVICES DEPARTMENT Planning • Building • Engineering Plan Review Corrections BLD20071046 10/24/07 Permit:Date: # WhiteADD/831NorthstreamLn Project Name/Address: Contact Person/Address/Fax: __________________________________________________________________________________________ __________________________________________________________________________________________ DianaWhite/DIANA.WHITE@COMCAST.NET Engineering EdwardSibrel Reviewer: Division: During review of the subject submittal it was found that the following information, corrections, or clarifications will need to be addressed: Note:Engineeringhandoutsandstandarddetailsmaybefoundat: http://www.ci.edmonds.wa.us/engr_dept.stm 1.Ifthesiteplannote,"Tieexistingdrainsintonewsystem,"iscorrect,thenthedetentionsystemisrequiredtobesizedforall impervioussurfaces,oldandnew.Ifthenoteisincorrect,thennoneoftheexistingroofandhardscaperunoffwillbedirectedtothe detentionsystem.Iftherooflinesaresuchthataportionoftheexistingroofsurfacemustdraintothedetentionsystem,thenthe capacityforthesystemmustbeadjustedaccordingly. 2.Itisunclearfromthenotesontheplanswhetherthereisinplaceanalreadyexistingdetentionsystem.Ifthereis,pleasespecifypipe size,length,andlocation.Otherwise,editthesiteplannotesforclarity. 3.Notethatifthereisnoexistingdetentionsystem,thenthereisno'credit'fordemolishingtheexistingdriveway,asthereisno detentioncapacitytotakeacreditagainst.Inthatcase,theentireextentofthenewdrivewayshallcountasnewimpervious. 4.Detentionsystemoutletshallbe6"indiameter. 5.Showhowandwherefootingsaretodrain.Notefootingdrainsarenottobeconnectedorflowtothedetentionsystem,butmaybe wyedintotheoutletpipe. 6.Submitaseparatesheetdetailingstormlinetobeinstalledincityright-of-way:includeexistingandproposedCBsandtheirinverts, nearbyutilitiesandtheircrossings,pipematerialandsize,lengthofrun,andextentofproposedasphaltsawcuts. 7.Accordingtothesiteplan,thedetentionsystemliespartiallywithina10'utilityeasement.Thedetentionsystemmust1)eitherbe movedoutoftheeasement,or2)acopyoftheeasementmustbeprovidedshowingthatsuchworkisallowedwithinitsborders,*and* buriedutilitieslocatedsothatpotentialconflictscanbeascertained. 8.Info:Aseparatesewerpermitshallbeissuedtocovertheinstallationofacleanoutoutsideofthenewaddition. Please resubmit three copies of the revised plans/documents to a Development Services Coordinator. You may contact me at 425-771-0220 if you have specific questions regarding these plan corrections. 1 October24,20071 DATE mailed/faxed/emailed PAGE OF.