Loading...
occupant load revised 2.pdfCOMMERCIAL KITCHEN OCCUPANCY 200 GROSS 156.2/200=1 COMMON AREA OCCUPANCY 100 GROSS 141.3/100=2 ACCESSORY STORAGE OCCUPANCY 6UU C.�,KU��j 54/300=1 x ' U �g m0� FE (K) l( I — — 0 1 0 ri0 55 L�\M _ D _11�, 40 OCCUP CV H w � POSTED EXIT SIGN ACCESSORY STORAGE OCCUPANCY 300 GRO55 0 \sf 120/300=1 1 , I 1 j 1 Y 1 1 I , >< 1 97sf' BUSINESS OCCUPANCY �L I 100 GROSS 129.4/100=2 I 125 sf ASSEMBLY 1 1 / • OCCUPANCY 15NE" 125 ,/15= 9 / \ ASSEMBLY OCCUPANCY �R_ r business - 1/100 7 occupants 115 NET _-� 6' 1170'7 sf 1 80.2/15=6 110 4 i ASSEMBLY co OCCUPANCY 1 11 i 89/15=6 1 �� 11 1 1 BUSINESS [)11 , 1 OCCUPANCY II i l I I 100 GRO55 I I— — _ II COMMON AREA 202.5/100=.Z— / I I I �1 OCCUPANCY 100 GROSS /1 II Dol I - 1 04 104.8/100=2 conc assemblyl- I o 48"�' -1/7-12 g �f i ; 1 occupants )FE ILo 1 I 42 o ---____ I 6 1 — bench - 1/18" - 3 _ occupants / tanding - 1/5 / 9 occupants POSTED EXIT SIGN; C' '/ 1 ACCES5113LE ROUTE / a^ fb S 11 EXIT 4 O UP 5 / unconc 6� assembly - 1/15 AS LY - 12 occupants 8 / OCCUPANC 15 NET 426/15=29 � 01 �r 299 sf ASSEMBLY unconc OCCUPANCY assembly -1/15 - 20 occupants � � � 15NET 1:125L0P_E__ 310/15=21 —7OWN 66" 48 nn A iNi �1 r1r1R Fr.PF.q.q PI AN APPROACH CLEAR FLOOR SPACEI I I I CLEAR sP X oI I APPROACH I I I NOTE: X=1'-0 IMINJ IF DOOR HAS BOTH A CLOSER AND A LATCH FRONT APPROACH pueHSAND PULL CLEAR] FLOOR SPACE i APPROACH NOTE: Y=3'-&" MIN: Y=4'-O" MIN, IF DOOR HAS A CLOSER AND LATCH: X=12" MIN, IF BOTH CLOSER AND LATCH ARE PROVIDED HINGE APPROACH PUSH SIDE APPROACH APPROACH ==�> HINGE APPROACH PULL SIDE (2 — — — — — — CLEARI APPROACH ==�> FLOORI SPACE r \\ I APPROACH NOTE: Y=4'-O" MIN: Y=4'-6" MIN, IF DOOR HAS A CLOSER ATC;H APPROACH PIIII SII7F I r r 404 DOORS AND DOORWAYS: 404.1 GENERAL DOORS AND DOORWAYS THAT ARE PART OF AN ACCESSIBLE ROUTE SHALL COMPLY WITH SECTION 404 404.2 MANUAL DOORS MANUAL DOORS AND DOORWAYS AND MAAUAL GATES, INCLUDING TICKET GATES, SHALL COMPLY WITH THE REQUIREMENTS OF SECTION 404,2 40 I DOUE3LE-LEAF DOORS AND GATES AT LEAST ONE OF THE ACTIVE LEAVES OF DOORWAYS WITH TWO LEAVES SHALL COMPLY WITH SECTIONS 404,2,2 AND 404,2.3 40422 2 CLEAR WIDTH DOORWAYS SHALL HAVE A CLEAR OPENING WIDTH OF 32" MIN, CLEAR OPENING WIDTH OF DOORWAYS WITH SWINGING DOORS SHALL BE MEASURED BETWEEN THE FACE OF THE DOOR AND STOP, WITH THE DOOR OPEN W DEGREES, OPENINGS, DOORS, AND DOORWAYS WITHOUT DOORS MORE THAN 24" IN DEPTH SHALL PROVIDE A CLEAR OPENING WIDTH OF 3Vo INCHES MIN. THERE SHALL BE NO PROJECTIONS INTO THE CLEAR OPENING WIDTH LOWER THAN 34 INCHES ABOVE THE FLOOR, PROJECTIONS INTO THE CLEAR OPENING WIDTH BETWEEN 34 INCHES AND 80 INCHES ABOVE THE FLOOR SHALL NOT EXCEED 4 INCHES, EXCEPTIONS: I. DOOR CLOSERS AND DOOR STOP` SHALL BE PERMITTED TO BE 78 INCHES MIN. ABOVE THE FLOOR 2, IN ALTERATIONS, A PROJECTION OF 5/S INCH MAX. INTO THE REQUIRED CLEAR OPENING WIDTH SHALL BE PERMITTED FOR THE LATCH SIDE STOP 404 2 3 1 FLOOR SURFACE FLOOR SURFACE WITHIN THE MANEUVERING CLEARANCES SHALL HAVE A SLOPE NOT STEEPER THAN 1:48 AND SHALL COMPLY WITH SECTION 302 404.2.4 THRESHOLDS AT DOORWAYS IF PROVIDED, THRESHOLD AT DOORWAYS SHALL BE 1/2 INCH MAX. IN HEIGHT. RAISED THRESHOLDS AND CHANGES IN LEVEL AT DOORWAYS SHALL COMPLY WITH SECTIONS 302 AND 303, of m niI►ir nfr f%I IDAAIT I (1A11 LOAD FACTOR FLOOR AREA OCCUPANCY LOAD (FLOOR AREA/LOAD FACTOR) ASSEMBLY, UNCONCENTRATED 15 NET 426 5F 29 TABLES & CHAIRS 89 5F 6 80.2 5F 6 113.3 5F 8 353 5F 24 KESTROOMS, CORRIDORS 100 GROSS 246.1 5F 3 KITCHEN, COMMERCIAL 200 GROSS 156.2 5F 1 ACCESSORY STORAGE 300 GROSS 120 5F 1 54 SF 1 BUSINESS 100 GROSS 129.4 SF 2 202.5 SF 3 TOTAL OCCUPANT LOAD FOR SPACE: 61 NOTE: Y=3'-&" MIN: Y=4'-O" MIN, IF DOOR HAS A CLOSER LATCH APPROACH PUSH SIDE NOTE: THE CITY OF EDMONDS RECOGNIZES THE SUBMITTED AND APPROVED OCCUPANT LOAD (OL). EXCEEDING THE APPROVED AND FOSTED OCCUPANT LOAD CONTITUTES A VIOLATION OF THE INTERNATIONAL FIRE CODE (IFC)., INTERNATIONAL BUILDING CODE (IL3C).g AND LOCAL ORDINANCES. THIS TYPE OF VIOLATION 5U6JECT5 THE OWNER/MANAGER TO ADDITIONAL ENFORCEMENT ACTION, INCLUDING THE N REQUIREMENT OF AN AUTOMATIC FIRE 7", SPRINKLER SYSTEM. Q O � O 00 O U U Q 0 z U Q 75 U) 0 L0 n z ry "t O w 2 z o J W w y- 9716 REGISTERED ARCHITECT tMICHELLE HELGESON OF WASHINGTON H 2 D A R C H I T E C T U R E D E S+ I G N 23020 EDMONDS WAY, #113 EDMONDS, WA 98020 P. 206 . 542 . 3 7 34 www.h2darchitects.com DATE: 3/20/2018 PERMIT SET EGRESS PLAN AND DETAILS Iv1/ \I1 r SCALE:1/4'' = 1'-0"