Loading...
occupant load.pdfr Diaper Changing Table stg Corri( E-03 N I 010 1 DO I I I ir e' EXIST STAIR EXIT ENTRY -LOBBY / 221 SF 150 SF / 442 sf 152s business - 1/100 - 2 occupants / .... _.-. -.._l T ROOM A-2.5-5 R / yrs - 20 kids per WA State DEL KITCHEN / 1 801 SF 007 812 sf 201 SF F24 y care - 1/35 203 s occupants comm kitchen - fire ex / —L1/200 - 1 occupant If-717 CORRIDOR Hw ntr _ 016 / ( ❑ ❑ 356 SF / 89 S1/100 / 3,042 sf busi6` � --- 56 EXIT - 7 occupants ROOM C-19-30 mos - 14 kids per WA State DEL 003 460 SF 464 sf day care - 1/35 - 14 occupants TOILET 006 64 SF r / / / / ELEVATOR EXIST ELEV/ELECT/ FIRE SPRINKLER 377 SF 379 sf 1j ❑ ❑ / LNDRY 009 71 SF ■ OUTDOOR PLAY 004 865 SF 877 S exercise - 1/50 - 18 occupants 93.5' DIAGONAL DISTANCE - 32' SEPARATION OF EXITS REQUIRED r �IL SEPARATION TOILET TOILET 0-1 57 SF 60 SF coo; 'mom i avi _ 400 /12'-8" exit / separation at room 002 w/ f d ROOM B-13-18 ° ♦ mos - 14 kids per WA State DEL \ 601 SF / S day care - 1/35 diaper changing 604 station � 37 -5 diagonal - 12 -6 - 18 occupants separation required at room 002 - Separation distance / ♦ is shown at room 002 due / to close tolerances. / Rooms 001 and 003 are / compliant. GATE DUMPSTER 019 89 SF FUNCTION OF SPACE # name FUnction Sf area area/occ tot occs 001 Room A Dad, care net 813 35 23.23 Or- I002 Room B Day care net 600 35 17.14 '003 Room C Day care net 467 35 13.34 Outdoor play na 855 50 17.30 I 005 Toilet Business areas 60 1t110 0.60 006 Toilet Business areas 69 1W 0.6_9 020 Toilet 'Business areas 5r1 1 0.51 �02.1 Toilet Business areas 33 1W 033 '007 Kitchen Kitchen/comm grass 196 200 0.98 {0,8 not used _. 009 '010 Laundry A,ccessori stg area _ gross 6T 300 0.23 _ not used �_---,. �15 Entry -Lobby Business areas gross 149.1 1001.49 016 Cord dor n a 360 100 3.60 019 Dumpster na 103 0 0' 79A5 • 1-4 OCCUPANCY • SPACE WILL BE FIRE SPRINKLED UNDER SEPARATE CONTRACT • TWO EXITS REQUIRED rP] TABLE 2902,1 TA13LF 1020A CORRIDOR FIRE-RESISTANCI RATIN'G REQUIRED FIRE - OCCUPANT RESISTANCE LOAD RATI NG (hours) OCCUPANCY SERVED BY Without With sprinkler CORRIDOR sprinkler SySt:errl'� system H -1, H-< H _ All Not Permitted Greater Not f,--H� �t: - � than 30 Permitted A B, E, F^, tvl. Greater 1 �•p S, a than 30 Greater Not f; �} S than 10 Permitted 1-2t 1-4 All Not 0 All Permitted N ot b 1 Perm i tted M-FNIMI M N UMBER OF REQUIREn PLUMBING FIxTURESa (See Sections 2902.1,1 and 2902_2,i WATER CLOSETS DRINKING (URINALS SEE FOUNTAINS i i SEC ON 419.2 OF LAVATORIES BATHTUBSI (SEE No. j CLASSIFICATION OCCUPANCY DESCRIPTION THE f�r'TER1�'�,7'fONAf SRC RS ; SEC tr-� �; rti {.: F TI I I PL UM. BiNG C€ DE j I/V T,E 1V,4 Tr<O`,►,A ' -- Male - Female Male Female PLUMBING CODE) i du Y Ure Mncr - ' 1-4 1 per 15 1 per 15 1 1 per 100 l child davcare -----------� 6 wc's required - 6 provided • 2 wc's in Toilet 005 • 2 we in Toilet 006 • 2 wc's in toilets 020 and 021 6 lays required - 10 provided • 2 lays in Toilet 005 • 2 lays in Toilet 006 • 2 lays in toilets 020 and 021 • 4 total in rooms 001, 002 & 003 — 1 drinking fountain required - 1 provided • 1 df in corridor 016 -- 1 tub -shower required - 1 provided • 1 tub -shower in toilet 020 r . LOWER LEVEL - floor plan - Egress 1 /4" _ 1 -011 TABLE 508.4 REQUIRED SEPARATION OF OCCUPANCIES (HOURS) A, E OCCUPANCY S NS I-1a, I-3, 1-4 1-2 Ra I F 2, S-2b, U Be' F-1, M, S-1 H4 H-2 H-3, H-4 H-5 S NS S NS S NS S NS S NS S NS S NS S NS S NS A, E N N 1 2 2 NP 1 2 N 1 1 2 NP NP 3 4 2 3 2 NP I -la, 1-3, 1-4 —— N N 2 NP 1 NP 1 2 I'l 2 NP NP 3 NP 2 NP 2 NP 1-2 — — — — N N 2 NP 2 NP 2 NP NP NP 3 NP 2 NP 2 NP Ra — — — — — — N N 1c 1 2c 1 2 NPI NP 3 NP L2 NP 2 NP F-2, S-2b, U —— — — ———— N N 1 2 NP NP 3 4 2 3 2 NP Be, F-1, M, S-1 — — — — — — — — — — N N NP NP 2 3 1 2 1 NP H-1 — — — — — — — — — — — — N NP NP NP NP NP NP NP H-2 — — — — — — — — — — — — — — N NP 1 NP 1 NP H-3, H-4 — — — — -- — — — — — — — — — — — 1a ----- NP -- - 1 -- - NP H-5 TABLE 601 FIRE -RESISTANCE RATING REQUIREMENTS FOR BUILDING ELEMENTS (HOURS) TYPE I TYPE 111 TYPE III TYPE Iv TYPE V BUILDING ELEMENT A B A B A B HT A I B Primary structural frame' (see Section 202) 3a 2a 1 0 1 0 HT 1 0 Bearing walls Exteriore• r 3 2 1 0 2 2 2 1 0 Interior 33 2a 1 0 1 0 1/HT 1 0 Nonbearing walls and partitions Exterior See Table 602 Wing Is an pa ions See nteriora 0 0 0 0 0 0 Section 602.4.8 0 0 Floor construction and associated secondary members (see Section 202) 2 2 1 0 1 0 HT 1 0 Roof construction and associated secondary members 1 /� b 1 b, c 1 b, c Oc 1 b c 0 HT b, c 1 0 (see Section 202) SECTION 602 CONSTRUCTION CLASSIFICATION TABLE 602 FIRE -RESISTANCE RATING REQUIREMENTS FOR EXTERIOR WALLS BASED ON FIRE SEPARATION DISTANCE", � FIRE SEPARATION DISTANCE = TYPE OF CONSTRUCTION OCCUPANCY GROUP He OCCUPANCY OCCUPANCY X (feet) GROUP F-1, M, S-11 GROUP A, B, E, F-2, I, R. S-2, U^ - X < 5b All 3 2 1 5!5X<10 IA 3 2 1 Others 2 1 1 IA,IB 2 1 is 10sX<30 IIB,VB 1 0 0 Others 1 1 1c All 0 0 Reichler Building - Daycare tenan, improvements 21827 76th Ave W, Edmonds, WA 98026 03 28 18 PERMIT - CONSTRUCTION 4435 REUISTERED ARCHITECT LRALPHW. ALLEN SWASHINGTON rev-1 - date - topic city comments - 07 10 18 rev-2 - date - topic rev-3 - date - topic rev-4 - date - topic rev-5 - date - topic rev-6 - date - topic CODE &LIFE SAFETY RE3U6 JUL 10 2018 dFOFEp� p D NT T1=0.1 a GRACE 7310 15TH AVE NW Seattle, Washington, 98117 ph 206 957 9800 fax 206 682 3159 rwallen@gracearchitectsplic.co