occupant load.pdfr
Diaper
Changing
Table
stg Corri(
E-03
N
I
010
1
DO
I I
I
ir
e'
EXIST STAIR
EXIT ENTRY -LOBBY /
221 SF 150 SF /
442 sf 152s
business - 1/100
- 2 occupants
/
.... _.-. -.._l T
ROOM A-2.5-5
R / yrs - 20 kids per WA State DEL
KITCHEN / 1
801 SF
007 812 sf
201 SF F24
y care - 1/35
203 s occupants
comm kitchen - fire ex /
—L1/200 - 1 occupant
If-717
CORRIDOR
Hw ntr _ 016 /
( ❑ ❑ 356 SF /
89 S1/100 / 3,042 sf
busi6` �
--- 56 EXIT
- 7 occupants
ROOM C-19-30
mos - 14 kids per WA State DEL
003
460 SF
464 sf
day care - 1/35
- 14 occupants
TOILET
006
64 SF
r
/
/
/
/
ELEVATOR
EXIST
ELEV/ELECT/
FIRE SPRINKLER
377 SF
379 sf
1j
❑ ❑ /
LNDRY
009
71 SF
■
OUTDOOR PLAY
004
865 SF
877 S
exercise - 1/50
- 18 occupants
93.5' DIAGONAL
DISTANCE - 32'
SEPARATION OF
EXITS REQUIRED
r �IL SEPARATION
TOILET TOILET 0-1
57 SF 60 SF
coo;
'mom
i avi _
400
/12'-8" exit /
separation at
room 002
w/ f d ROOM B-13-18
° ♦ mos - 14 kids per WA State DEL
\ 601 SF
/ S day care - 1/35
diaper changing 604 station
� 37 -5 diagonal - 12 -6 - 18 occupants
separation required at room
002 - Separation distance
/ ♦ is shown at room 002 due
/ to close tolerances.
/ Rooms 001 and 003 are
/ compliant.
GATE
DUMPSTER
019
89 SF
FUNCTION OF SPACE
#
name
FUnction
Sf
area area/occ tot occs
001
Room A
Dad, care
net
813 35 23.23
Or-
I002
Room B
Day care
net
600 35 17.14
'003
Room C
Day care
net
467
35 13.34
Outdoor play
na
855
50 17.30 I
005
Toilet
Business areas
60
1t110
0.60
006
Toilet
Business areas
69
1W
0.6_9
020
Toilet
'Business areas
5r1
1
0.51
�02.1
Toilet
Business areas
33
1W
033
'007
Kitchen
Kitchen/comm
grass
196
200
0.98
{0,8
not used
_.
009
'010
Laundry
A,ccessori stg area
_
gross
6T 300 0.23
_
not used
�_---,.
�15
Entry -Lobby
Business areas
gross
149.1 1001.49
016
Cord dor
n a
360 100 3.60
019
Dumpster
na
103 0 0'
79A5
•
1-4 OCCUPANCY
•
SPACE WILL BE FIRE SPRINKLED UNDER
SEPARATE CONTRACT
•
TWO EXITS REQUIRED
rP] TABLE 2902,1
TA13LF 1020A CORRIDOR FIRE-RESISTANCI RATIN'G
REQUIRED FIRE -
OCCUPANT
RESISTANCE
LOAD
RATI NG (hours)
OCCUPANCY
SERVED
BY
Without
With sprinkler
CORRIDOR
sprinkler
SySt:errl'�
system
H -1, H-< H _
All
Not
Permitted
Greater
Not
f,--H� �t: -
�
than 30
Permitted
A B, E, F^, tvl.
Greater
1
�•p
S, a
than 30
Greater
Not
f;
�} S
than 10
Permitted
1-2t 1-4
All
Not
0
All
Permitted
N ot
b
1
Perm i tted
M-FNIMI M N UMBER OF REQUIREn PLUMBING FIxTURESa (See Sections 2902.1,1 and 2902_2,i
WATER CLOSETS DRINKING
(URINALS SEE
FOUNTAINS i
i
SEC ON 419.2 OF LAVATORIES BATHTUBSI (SEE
No. j CLASSIFICATION OCCUPANCY DESCRIPTION THE f�r'TER1�'�,7'fONAf
SRC RS ; SEC tr-� �; rti {.: F TI I I
PL UM. BiNG C€ DE j I/V T,E 1V,4 Tr<O`,►,A '
-- Male - Female Male Female PLUMBING CODE)
i
du Y Ure Mncr
-
' 1-4 1 per 15 1 per 15 1 1 per 100
l child davcare -----------�
6 wc's required - 6 provided
• 2 wc's in Toilet 005
• 2 we in Toilet 006
• 2 wc's in toilets 020 and 021
6 lays required - 10 provided
• 2 lays in Toilet 005
• 2 lays in Toilet 006
• 2 lays in toilets 020 and 021
• 4 total in rooms 001, 002 & 003
— 1 drinking fountain required - 1 provided
• 1 df in corridor 016
-- 1 tub -shower required - 1 provided
• 1 tub -shower in toilet 020
r . LOWER LEVEL - floor plan - Egress
1 /4" _ 1 -011
TABLE 508.4
REQUIRED SEPARATION OF OCCUPANCIES (HOURS)
A, E
OCCUPANCY
S NS
I-1a, I-3, 1-4
1-2 Ra
I
F 2, S-2b, U
Be' F-1, M,
S-1
H4
H-2
H-3, H-4
H-5
S
NS
S
NS
S
NS
S
NS
S
NS
S
NS
S
NS
S
NS
S
NS
A, E
N
N
1
2
2
NP
1
2
N
1
1
2
NP
NP
3
4
2
3
2
NP
I -la, 1-3, 1-4
——
N
N
2
NP
1
NP
1
2
I'l
2
NP
NP
3
NP
2
NP
2
NP
1-2
—
—
—
—
N
N
2
NP
2
NP
2
NP
NP
NP
3
NP
2
NP
2
NP
Ra
—
—
—
—
—
—
N
N
1c
1 2c
1
2
NPI
NP
3
NP
L2
NP
2
NP
F-2, S-2b, U
——
—
—
————
N
N
1
2
NP
NP
3
4
2
3
2
NP
Be, F-1, M, S-1
—
—
—
—
—
—
—
—
—
—
N
N
NP
NP
2
3
1
2
1
NP
H-1
—
—
—
—
—
—
—
—
—
—
—
—
N
NP
NP
NP
NP
NP
NP
NP
H-2
—
—
—
—
—
—
—
—
—
—
—
—
—
—
N
NP
1
NP
1
NP
H-3, H-4
—
—
—
—
--
—
—
—
—
—
—
—
—
—
—
—
1a
-----
NP
-- -
1
-- -
NP
H-5
TABLE 601
FIRE -RESISTANCE RATING REQUIREMENTS FOR BUILDING ELEMENTS (HOURS)
TYPE I
TYPE 111
TYPE III
TYPE Iv
TYPE V
BUILDING ELEMENT
A
B
A
B
A
B
HT
A
I B
Primary structural frame' (see Section 202)
3a
2a
1
0
1
0
HT
1
0
Bearing walls
Exteriore• r
3
2
1
0
2
2
2
1
0
Interior
33
2a
1
0
1
0
1/HT
1
0
Nonbearing walls and partitions
Exterior
See Table 602
Wing Is an pa ions
See
nteriora
0
0
0
0
0
0
Section 602.4.8
0 0
Floor construction and associated secondary members
(see Section 202)
2
2
1
0
1
0
HT
1 0
Roof construction and associated secondary members
1 /� b
1 b, c
1 b, c
Oc
1 b c
0
HT
b, c
1 0
(see Section 202)
SECTION 602
CONSTRUCTION CLASSIFICATION
TABLE 602
FIRE -RESISTANCE RATING REQUIREMENTS FOR EXTERIOR WALLS BASED ON FIRE SEPARATION DISTANCE", �
FIRE SEPARATION DISTANCE =
TYPE OF CONSTRUCTION OCCUPANCY GROUP He
OCCUPANCY
OCCUPANCY
X (feet)
GROUP F-1, M, S-11
GROUP A, B, E, F-2, I, R. S-2, U^
- X < 5b
All
3
2
1
5!5X<10
IA
3
2
1
Others
2
1
1
IA,IB
2
1
is
10sX<30
IIB,VB
1
0
0
Others
1
1
1c
All
0
0
Reichler Building
- Daycare tenan,
improvements
21827 76th Ave W, Edmonds,
WA 98026
03 28 18
PERMIT - CONSTRUCTION
4435 REUISTERED
ARCHITECT
LRALPHW. ALLEN
SWASHINGTON
rev-1 - date - topic city comments - 07 10 18
rev-2 - date - topic
rev-3 - date - topic
rev-4 - date - topic
rev-5 - date - topic
rev-6 - date - topic
CODE &LIFE SAFETY
RE3U6
JUL 10 2018
dFOFEp� p D NT
T1=0.1 a
GRACE
7310 15TH AVE NW
Seattle, Washington, 98117
ph 206 957 9800
fax 206 682 3159
rwallen@gracearchitectsplic.co