Pre-Application Meeting
Pre-Application Meeting
Date: January 10, 2008
Review By: Mike Clugston, Planning Division
rd
Project Name: Old Milltown 3 Floor Condominiums
th
Site Address: 201 5 Avenue South
Zone: Downtown Business - Downtown Retail Core (BD-1)
Contact: Ralph Allen, Grace Architects (206-957-9800)
Description: 3 residential units
Use
Use
Proposed Use: Multiple Residential 3 dwelling units with enclosed parking.
Allowed Use: Yes. Multiple residential use is permitted pursuant to Edmonds Community Development
Code (ECDC) 16.43.020.
Development Standards
Development Standards
Setbacks: There are no property line setbacks in the BD-1 zone with the exception of a required 15
setback from any adjacent R-zoned property. In this case, that exception does not apply. Most of the
third floor is not built to the property line thereby giving the appearance of a varied setback. A small
portion of roof of the Danielson residence (northeast corner near the gazebo) appears to protrude into the
right-of-way.
Height: Maximum height is 30 feet for buildings with a ground floor ceiling height of 15 feet. Existing
buildings may be added onto or remodeled without adjusting the existing height of the ground floor to
meet the specified minimum height so long as the addition or remodel does not increase the building
footprint or its frontage along a street by more than 25 percent. The proposal actually appears to meet
both criteria because the building was a remodel.
According to the Site Plan provided (A-1.0), the average grade is 67.74 feet which makes the maximum
height 97.74 feet. The third floor addition appears to meet the requirement. The chimney built into the
gazebo on the northwest corner also appears to meet the 97.74 foot limit. However, it appears that four
chimneys and a central skylighted atrium area containing an elevator and stairwell exceed the maximum
height.
Chimneys
Several height exceptions are defined in ECDC 21.40.030. Portions applicable to this project are
described below:
3. Elevator penthouses, not to exceed 72 square feet in horizontal section, or three feet in
height, for that portion above the height limit;
4. Chimneys, not to exceed nine square feet in horizontal section or more than three feet in
height, for that portion above the height limit. In RM districts, chimneys shall be clustered.
No multiple-flue chimney shall exceed 39 square feet in horizontal section. The first
chimney shall not exceed nine square feet in horizontal section, and other chimneys shall
not exceed six square feet in horizontal section;
5. Vent pipes not to exceed 18 inches in height above the height limit; and
6. Standpipes not to exceed 30 inches in height above the height limit. \[Ord. 3569 § 2,
2005\].
As proposed, the maximum height for the building is 97.74 feet. An additional 3 feet for chimneys
would be 101.74 feet. The four chimneys appear to be within this limit. However, the chimneys must
also be less than 9 square feet in section unless they are multiple-flue chimneys (multiple-flue
chimneys must be less than 39 square feet in section). While it is difficult to tell, it appears that each
chimney is single-flue and each appears to exceed the 9 square foot requirement (between 12 and 21
square feet). The four chimneys must meet the square footage requirement to use the additional 3
feet above the height limit or a variance would be required.
Atrium
The atrium was not present during the ADBs review of the project (ADB-07-67). As a result, it was
not approved by the ADB. If the atrium is a desired architectural element for the project, the project
would have to go back to the ADB for their approval and the structure must comply with all applicable
codes.
Additional height exceptions applicable in the BD zones are described in 16.43.030.C.4. One specific
to this project reads:
a. A single decorative architectural element, such as a turret, tower, or clock tower, may
extend a maximum of five feet above the specified height limit if it is designed as an
integral architectural feature of the roof and/or facade of the building. The decorative
architectural element shall not cover more than five percent of the roof area of the
building.
The top of the atrium extends above the maximum height of 97.74 feet. In fact, it appears to be about
4.5 feet greater than the limit. If the intent is to use the 5-foot exception described above, the atrium
may not cover more than 5% of the roof area of the building. In this case, the roof area would consist
of that area covered by the third floor addition. If the atrium does not meet the above requirements, a
variance would be required.
Parking: Pursuant to ECDC 17.50.010.C.1, residential uses in the downtown business area shall provide
one parking stall per dwelling unit. Three stalls are required; six enclosed stalls are proposed.
Environmental Regulations
Environmental Regulations
SEPA Review: A Determination of Non-Significance was issued for the proposed addition on November
15, 2007 as part of design review of the project (ADB-07-67). No comments were received.
Critical Area Determination: A critical area determination was performed for the subject parcel (CRA-
2006-0097). A study was required due to potential erosion hazard on the eastern portion of the site. An
erosion and sediment control plan prepared in accordance with ECDC 18.30 should sufficiently address
potential impact to the hazard.