Loading...
OVWSD Equipment center.pdfg FI) CITY OF EDMONDS 121 51" Avenue North'- Edmonds, WA 98020 Phone: 425.771.0220 • Fax: 425.771.0229 • Web: www.ci,edmonds.wa.us �nF 1 ago DEVELOPMENT SERVICES DEPARTMENT: PLANNING DIVISION Date: August 26, 2009 Review By: Mike Clugston, AICP Project Name: Olympic View Water and Sewer District E ui ment and Materials Center Site Address: 23725 Edmonds Way Zone: I Residential Multifamily RM -1.5 Contact: Roger Eberhart, 425-774-7769 Description: Equipment and Materials Center Use Proposed Use: Equipment and material storage facility. Allowed Use: Yes. Local public facilities are conditional uses in the RM zones per Edmonds Community Development Code (ECDC) Chapter 16.30. The project received a conditional use permit in 2008 (CU - 08 -03). Development Standards Setbacks: The decant station will be located approximately 20' from the eastern property line which would have a minimum side setback of 10'. Fences must be 6' or less to be located within a setback area. Lot Coverage: Structural lot coverage calculations for existing and proposed structures will be required and may not exceed 45%. Height: 25 feet as measured from average original grade + 5 feet for roof having a slope of 4" in 12" or greater. It appears that the new decant station will be slightly lower than the existing garage structure which appears to be about 24' tall. Height calculations will be required for the new decant structure. It appears that the pole -mounted lights will also be less than 25'. Parking: The applicant has indicated that no employees will man the site. Rather, employees will come intermittently to trade vehicles, drop off materials, etc. As a result, no parking stalls are required. The site plan does identify 4 parking stalls. If employees will remain and work at the site, ECDC 17.50.020.0.10 requires 1 space per 2 employees for a maintenance yard. With the 4 parking stalls, up to 8 employees could do work based at the site. Environmental Regulations SEPA Review: SEPA was completed with the associated conditional use permit. Minimum Lot Area Minimum Minimum Minimum Maximum Maximum Lone per Dwelling Unit Street Side Rear Height Coverage Setback Setback Setback RM -1.5 Not Applicable 15' 10' 15' 25'+ 5' 45% Setbacks: The decant station will be located approximately 20' from the eastern property line which would have a minimum side setback of 10'. Fences must be 6' or less to be located within a setback area. Lot Coverage: Structural lot coverage calculations for existing and proposed structures will be required and may not exceed 45%. Height: 25 feet as measured from average original grade + 5 feet for roof having a slope of 4" in 12" or greater. It appears that the new decant station will be slightly lower than the existing garage structure which appears to be about 24' tall. Height calculations will be required for the new decant structure. It appears that the pole -mounted lights will also be less than 25'. Parking: The applicant has indicated that no employees will man the site. Rather, employees will come intermittently to trade vehicles, drop off materials, etc. As a result, no parking stalls are required. The site plan does identify 4 parking stalls. If employees will remain and work at the site, ECDC 17.50.020.0.10 requires 1 space per 2 employees for a maintenance yard. With the 4 parking stalls, up to 8 employees could do work based at the site. Environmental Regulations SEPA Review: SEPA was completed with the associated conditional use permit. Critical Area Determination: A critical areas checklist was completed in 1998 (CRA -1998-0244) and indicated a waiver from further study. Design Architectural Desi n Board ADB Review: The ADB approved the design of the site, structures and landscaping in 2009 in permit ADB -09-21. The applicant has selected the Cercidiphyllum japonicum 1 Katsura Tree as the street tree for the site which is in accordance with the Edmonds Street Tree Plan. The five Katsura trees are proposed to be located on OVSWD property rather than within the sidewalk area itself. Signage: None shown. Any signage must comply with ECDC 20.60 Questions / Notes • On Sheet A-3.0, there is 'screen wall for climbing plants' indicated — is that attached to the metal wall or in place of it?