PaigeCU1.pdf City of Edmonds PLAN REVIEW COMMENTS BUILDING DIVISION (425) 771-0220 DATE: August 19, 2008 TO: Douglas Paige FAX: 425-672-1425 FROM: Ann Bullis, Building Official RE: Plan Check: 2008-0560 Project: Paige Change of Occupancy for Hair Salon Project Address: 605 Main Street During review of the plans for the above noted project, it was found that the following information, clarifications or changes are needed. Please provide written responses to each comment as to how it has been addressed and where changes can be found on the plans. Please submit revised plans/documents to a Permit Coordinator. 1.On the site plan, dimension the distance from the exterior wall of the building to the property lines. 2.Where the exterior wall is 5 feet or less to the property line, combustible exterior wall coverings shall not exhibit sustained flaming per NFPA 268. Provide manufacturer’s information for siding showing compliance. IBC 1406.2.1.1 3.On the site plan, dimension the width and show slope of accessible path of travel from the accessible parking stall to the lift. 4.Provide manufacturer’s information for the proposed wheelchair lift, including being exposed to weather. Show compliance to ICC/ANSI A117.1 Section 410. 5.Dimension the width of the new stairway. 6.Provide framing plan for new landing. On detail 13/T1.1, provide engineered calculation to justify ledger attachment. 7.Gate at landing also acts as a required guard. Increase height to 42”, provide gate hardware information, and provide a sign that the gate must be closed when wheelchair lift is not in use. 8.Revise accessible parking stall details to include a sign at the head of the stall, 60” from the parking surface to the bottom of the sign. 9.On the restroom detail, note the height of the vertical grab bar. Turning radius encroaches into toilet space, but toilet does not permit toe clearance (ICC/ANSI A117.1 section 305 & 306). Please revise. 10.Upgrade deck guardrail to meet current code, including 42” minimum height, <4” sphere between intermediate rails, and load requirements. 11.Show energy code compliance as noted in WSEC 1133 for Change of Use. 12.Ventilation must be provided either mechanically or with natural ventilation using building openings (windows and doors) in accordance with the State Ventilation Indoor Air Quality Code. a.Natural ventilation: Provide in each room or area at the rate 4% of the floor area. Show the calculations on the plans. OR b.Mechanical ventilation: Provide outdoor air at the rates specified in VIAQ Table 3-4 (based on the occupant load established for the building) to each room or area. The system must be balanced (supply and return/exhaust). Provide mechanical plans and calculations showing compliance. Provide manufacturer’s specs for the mechanical units to be installed. 13.Provide minimum 50 cfm exhaust fan in the restroom. Page 2 of 2