PCC plumbing and mechanical BLD20080099 - 02-19-2008(2).pdfCity o� f Edmonds Wastewater Pretreatment Program 200 2 d Ave S., Edmonds, WA 98020 Office: (425) 672-5755 Mobile: (206) 595-3117 WIM111-IT1311 Project Name/ Address: PCC Natural Markets, 9803 Edmonds Way, Edmonds, WA Contact Person/Address/Fax: Steve Bloedel, Mechanical Designer, HV Engineering, Inc., Seattle WA, ph: 206-706-9669 X10, fax: 206-706-1830 Reviewer: Jon Lein Division: Wastewater Treatment Plant / Pretreatment The subject application has been reviewed but cannot be completed until the following items have been addressed/completed. Please submit 3 sets of revised drawings to a Development Services Permit Coordinator, if required. Plumbing/Mechanical Comments 1. Over all the GGI (out side grease interceptor) looks pretty good with only minor changes required. • All legs and tees are required to be 6" PVC per Ordinance. • All legs must be 12" above the vessel floor • Please include inlet venting for the GGI. • The risers Oust 6" pipe) should be at least 4" above the water surface. • Be sure to specify stainless steel straps and anchor bolts on the top and below each riser/drop leg. (The stainless steel conduit strap kits work well in this application.) • Please slope grade to ensure runoff is diverted from M/H lids. Notes: See the enclosed cutout for detail. W I Gaskstsci. Water light, Castings and Bolted lids See Mote 8 Contractor to Adjust (See Note 6) To Grade 1" MIN. PVC Vent Required (sego note 12) 2.5` to 5' Water Tight Manhole Frecost Idattle Adapter, ..._ �" " seen .; .. 6" PVC Coupling :.� (typical (see nottio) 9" min or tz all Risers equ?d aste --3 inlet v a Outlet --> a er Sur soca Coupling C nactlon at (see nate 1t1} building to follow' AVAYD standards Stainless Steal Strap for side sewarr .`' and 5/8" Anchor Solt Installations nate t5 {Typical} 30" Grout around 12 bath sides i. 1 of precast baffle : 2a Lenoth 1/3 tenoth PRECAST CONCRETE VAULT. UTILITY VAULT CO. INC. OR EQUAL (SEE NOTE 4) SIZE ACCORDING TO UNIFORM PLUMBING CODE—MOST CURRENT VERSION NOTES- INSTALL "PER MANUFACTURE REQUIREMENTS" 1. Gray—Water only. Block—Water shall be carried by seperate side sewer, 2. Locate interceptor within close proximity of drive for access by taint. vehicle. 3. it vault is not slotted to accept precast cane, baffle then precast cone. shall be held in place by (2) 3"x3'x3/8" angle (oft, long) attached to vault wall with (4 ea) 1/2" bolts and nuts (with washers) spaced 14" O.C. angle and fasteners shall be stainless steel. 4. Precast vault and baffle shall have knockouts at all pipe openings. if knockouts are not present then pipe openings shall be 2 larger than pipe diameter, 5. Position pipe risers below access openings to allow clear accessto riser and vault chamber for sampling & Inspection, 6, Lids, Frames, and Bolts shall meet District standards for manhole lids and/or clean—outs as applicable. 7. Connections through concrete walls require water tight manhole adapters. Seal all pipe connections with nonshrink grout. 8. Clean --guts required per District standards (2.5` to 5' from vouit). 9, gill with clean water prior to start up of system. 10. Romoc 5011 coupling or approved equal ALDERWOOD WATER DISTRICT 11. Discharge required to comply with District Dischorge limits 12. Interceptors shall have venting per Uniform PRE—TREATMENT INTERCEPTOR Plumbing Code. (1" minimum) 13. Vault and fittings shall be water tight. 14, All fittings shall be designed for grease retention, . 15. Liquid depth shall not be less then 2.5' nor greater DATE: 4--01 than 6', per UPC H 105.2.2 APPROVED BY:l.c.lt DISTF ICT ENGINEER