Loading...
Plan Review Comments for Panera Bread 101130.doc City of Edmonds Wastewater Pretreatment Program nd 200 2 Ave S., Edmonds, WA 98020 Office: (425) 672-5755 Mobile: (206) 595-3117 Plan Review Comments Plan Check #: Date: PRE20100014 November 30, 2010 th Project Name/ Address: Panera Bread, 7929 244 ST. S.W., Edmonds, WA, 98020 Contact Person/Fax or Email: Leslie Ford / LFord@ARCV.com Reviewer: Division: Jon LeinWastewater Treatment Plant / Pretreatment The subject application has been reviewed but cannot be completed until the following items have been addressed/completed. Please submit 3 sets of revised drawings to a Development Services Permit Coordinator, if required, or a written response to the review comments to the Development Services Permit Coordinator and the Pretreatment Reviewer. 1. I would strongly recommend that you locate the outside grease interceptor (GI), number 8 on your site plan, much closer to the kitchen. Otherwise, the line running from the kitchen fixtures to the GI has the potential to need much preventative maintenance to prevent plugging with grease. Alternative sites for the GI include the existing parking or the drive-through lane. Try to locate the GI as close to the kitchen fixtures as possible and ensure it is properly rated for traffic etc. 2. The GI must be approved by Pretreatment. Please see the City of Edmonds Grease Trap and Grease Interceptor Permit Submittal Requirements forms. 3. The following fixtures must be connected to the GI: a. Mop sink b. 3-comp sink c. dishwasher d. Prep sink, if used for meat e. Floor drains in the scullery/food prep area 4. The current plans do not show enough detail to determine if a grinder or disposal will be used. Pretreatment strongly discourages the use of a grinder/disposal in all kitchens. Please clarify if the use of a disposal/grinder is planned in the kitchen area and the GI will be required to be sized up to accommodate it. 5. There is already a GI in-service at the current Barlee’s site. If this existing GI is abandoned and replaced as per the plans, follow proper protocol to abandon it. 6. 3-comp sink – follow County Health Department standards for isolating the sanitize sink from the GI by either including a funnel/air gap if using the same line as the wash/rinse sink to the GI or preferably using a dedicated plumbing line to a floor sink that connects to the gray water line. Please call me Monday-Thursday for questions and assistance. Jon Lein City of Edmond Pretreatment Technician 425-672-5755 206-595-3117 (cell)