Plan review comments for Subway 110912.doc
City of Edmonds Wastewater Pretreatment Program
nd
200 2 Ave S., Edmonds, WA 98020
Office: (425) 672-5755 Mobile: (206) 595-3117
Plan Review Comments
Plan Check #: Date:
BLD20110742 Sept. 12, 2011
Project Name/ Address:
Subway/10016 Edmonds Way #D, Edmonds, WA
Contact Person/Fax or Email:
Shangguan, Sue/Sue@Woodmanconstruction.com
Reviewer: Division:
Jon LeinWastewater Treatment Plant / Pretreatment
The subject application has been reviewed but cannot be completed until the following
items have been addressed/completed. Please submit 3 sets of revised drawings to a
Development Services Permit Coordinator, if required, or a written response to the review
comments to the Development Services Permit Coordinator and the Pretreatment
Reviewer.
1. I see that the plumbing is deferred in your submitted plans. Line drawings for your
fixture connections will be required. The comments below are directed for your future
plumbing plans after I reviewed your kitchen layout in your submitted plans.
2. An approved outside grease interceptor (GI) is currently on site and its connection is
already inside your facility. I believe one of the floor sinks is connected to the grease
interceptor. Many grease interceptors have a useable service life of 10-20 years. The
should
interceptor for your food service had been repaired approximately 3 years ago and
be in relatively good condition. Before I can sign off for the plumbing final, I will need
to inspect the GI to ensure all of the downlegs are intact and in good condition and
observe a 24-hour leak test for the vessel.
3. These fixtures must be connected to your GI:
a. #36 – 3-comp sink
b. #37 – mop sink
These fixtures should not be connected to your GI:
a. #31 – hand sink
b. #41 - vegetable sink
c. #42 hand sink
4. 3-comp sink – follow Health Department standards for isolating the sanitize sink from the
GI by either including a funnel/air gap if using the same line as the wash/rinse sink to the
GI or preferably using a dedicated plumbing line to a floor sink that connects to the gray
water line.
Please call me Monday-Thursday for questions and assistance.
Jon Lein
City of Edmonds Pretreatment Technician
425-672-5755
206-595-3117 cell