Loading...
Plan review comments for The Maharaja 081201.doc City of Edmonds Wastewater Pretreatment Program nd 200 2 Ave S., Edmonds, WA 98020 Office: (425) 672-5755 Mobile: (206) 595-3117 Plan Review Comments Plan Check #: Date: BLD20080951-953 Dec. 2, 2008 th Project Name/ Address: The Maharaja, 201 5 Ave. S., #101, Edmonds, WA, th Project Name/ Address: Old Town Steakhouse, 201 5 Ave. S., #201, Edmonds, WA. th Project Name/ Address: Banquet Room, 201 5 Ave. S., #301, Edmonds, WA. Contact Person/Fax or Email: Ralph Allen, rwallen@gracearchitectspllc.com Reviewer: Division: Jon LeinWastewater Treatment Plant / Pretreatment The subject application has been reviewed but cannot be completed until the following items have been addressed/completed. Please submit 3 sets of revised drawings to a Development Services Permit Coordinator, if required, or a written response to the review comments to the Development Services Permit Coordinator and the Pretreatment Reviewer. Hello Ralph, I see that the plumbing permits/submittals are defered. In looking over the plans for the restaurants, I have some comments to assist you when you complete the submittals. I have combined my comments for all three permits (BLD20080951-953) since they are in the same building and you are listed as the applicant for all three permits. 1.Both Old Town Steakhouse and The Maharaja have these fixtures indicated on the plans: 3 comp sink (the wash and rinse sinks are required to be connected to the grease interceptor (GI), the sanitize sink connected to the side sewer with an air gap that meets County Health standards). A dishwasher is indicated for both kitchens but the plans have no prewash sinks listed. I assume that each food service will have a prewash sink adjacent to the dishwasher. The prewash sinks, along with the dishwashers, are required to be connected to the GI. Both restaurants have mop sinks. These are required to be connected to the GI. Dump sinks for each restaurant are indicated in the plans for the bar/lounge areas. These sinks should be connected to the side sewer, not the GI. 2.Both Old Town Steakhouse and The Maharaja should have all floor drains in the kitchen prep areas and wash areas connected to the GI. 3.I noticed that there is a 2 comp sink listed as a prep sink for the Old Town Steakhouse. If any of the compartments are planned for meat prep, those compartments are required to be connected to the GI. Vegetable food prep sinks are not required to be connected to the GI. 4.Disposals – I did not see disposals listed in the current plans that did not include the plumbing submittals. I strongly recommend that disposals are not included in either of the kitchens. The City believes commercial food waste belongs in solid waste, not the sanitary sewer. Disposals can increase the required pump-outs of the GI due to additional solids entering the GI. 5.Comments for the Banquet Room – In discussing this with the Building Department, I understand this facility will be shared with both food services. Is it reasonable to assume that whoever uses the Banquet Room will wash dishes in their own kitchen? 6. Grease interceptor operation and maintenance for multiple tenants – please remember that Gregg Production Associates, Inc. (GPA) is considered both the “user” and the “facility” as outlined in the Memorandum of Understanding Regarding Grease Interceptors between GPA and the City of Edmonds. It is up to GPA to determine how to charge for the maintenance and operation of the GI as well as ensure that the tenants are in compliance with the City code. In this instance, Pretreatment will directly deal with GPA instead of the individual food services when there are compliance issues. Ralph, please do not hesitate to call me for questions or concerns. It is good to see the project progressing. Jon Lein City of Edmond Pretreatment Technician 425-6725755 206-595-3117 (cell)