Loading...
Plans.pdfGENERAL NOTES 1. These drawings have been prepared primarily to safeguard against major structural damage and loss of life, not to limit damage or maintain function -as per requirements of the current accepted building code as listed in the Basis for Design. 2. An experienced licensed contractor with a working knowledge of applicable codes and industry accepted standard practices shall perform the work depicted in these drawings. 3. All work shall conform to the minimum standards of the current governing building code and industry specific specifications and standards. The contractor shall comply with requirements of all regulatory agencies with authority over any portion of the work. Work not explicitly shown on these drawings shall conform to all applicable codes and accepted standard practices. 4. The contractor shall verify all dimensions, elevations and conditions on these drawings with the architectural and all other discipline drawings prior to start of construction. Notify architect or FOR in writing before the start of construction regarding discrepancies, omissions or variations, or they shall become the sole responsibility of the contractor. Notes and the specific details on these drawings take precedence over general structural notes and typical details. 5. Construction methods are not indicated on these drawings. The contractor shall be solely responsible for all methods, sequences and procedures of construction. The contractor shall provide adequate shoring, bracing, formwork, etc. as required for the protection of life and property during construction. 6. Openings, pockets, etc. larger than 6 inches shall not be placed in structural members unless specifically detailed on these drawings. When drawings by others show Items in structural members not shown on the structural drawings, notify the engineer in writing to determine correct disposition. 7. Site visits by the FOR are a resource for the contractor and shall not be considered as special inspections. 8. General inspection and special inspection shall be performed during construction as required by the local governing municipality. BASIS FOR DESIGN 1. Governing Building Code: 2012 International Building Code 2. Occupancy Category: II 3. Roof Loads: Dead Load = self weight + 2.0 psf misc. dead load Live Load = 20 psf Snow Load = 25 psf (minimum required snow load) 4. Wind Design: Basic Wind Speed = 110 mph Wind Exposure = C Mean Roof Height = less than 15'-0" 5. Seismic Design: Wind loads govern lateral structural design. STRUCTURAL STEEL 1. Structural steel members shall conform to the following standards and material properties, U.N.O.: Standard steel shapes: ASTM A36 (36 ksi) Rolled wide flange sections: ASTM A992 (50 ksi) Bars and plates: ASTM A36 (36 ksi) Tubes and pipes: ASTM A500 Grade B (46/42 ks!) Standard pipes: ASTM A53 Grade B (35 ks!) Cold formed tubes, studs, etc.: ASTM A653 (50 ksi) High strength bolts: ASTM A325 All other bolts: ASTM A307 2. Where steel beam is used in connection to wood framing, a 3x DF-L stud grade plate will be bolted to the top flange with 1/2" dia. bolts staggered at 24" o.c. 3. Structural steel shall be fabricated and erected in accordance with AISC specifications or the design fabrication and erection of structural steel buildings. 4. All welds shall be minimum 1/8" E70XX all around weld, U.N.O. 5. Welders shall be AWS certified or equivalent (WAVO). All welding shall use E70 series low hydrogen electrodes. All welding shall conform to the latest American Welding Society standards; welds on drawings are shown as shop welds. Contractor may shop weld or field weld at his discretion. All full penetration welds shall be tested and certified by an independent testing laboratory. 6. All bolts shall be installed as bearing -type connections with threads excluded from shear plane (type "x" connection), U.N.O. High -strength bolts shall be snug tightened using any AISC approved method and do not require special inspections unless noted otherwise. All bolts in slotted or oversize holes and all high -strength bolts shall be installed with washers. 7. All expansion or epoxy bolts shall have current ICBO/ICC rating for material into which installation occurs. Headed studs shall conform to all requirements of the latest edition of the "recommended practices for stud welding" and the "structural welding code" published by AWS. All bolts, anchor bolts, expansion bolts, etc, shall be installed with steel washers at face of wood. 8. Grout beneath column bases or bearing plates shall be 5000 psi minimum non -shrink flowable grout or drypack. Install grout under bearing plates before framing members are installed. At columns, install grout under base plates after column has been plumbed but prior to floor or roof installation. Grout depth shall be sufficient to allow grout or drypack to be placed beneath plate without voids. 9. Welded moment frame connections shall comply with the following requirements: Access holes shall be smooth and free of notches. Minimum preheat per AWS requirements shall be maintained for all welds including tack welds. Verify preheat with temperature indicating crayons. Weld material shall comply with Charpy V-Notch requirement of 20 ft-lbs at -20" F. End dams are not allowed. All weld layers shall be completed full width of flange before new layer is started. Maximum layer thickness equals 1I/<", maximum bead width equals 5/8". Grind edges of weld smooth and flush with edges of abutting parts. Notches or grooves shall be filled and ground smooth. 10. All misc. welds not noted, including stiffeners, misc. plates, etc. shall be per AISC manual table J2.4. STRUCTURAL ALUMINUM 1. All aluminum alloys shall be minimum 6061-T6 with minimum tensile yield stress 35 ksi, U.N.O. 2. All aluminum welds shall conform to current aluminum specifications, 3. Aluminum parts shall be welded with an inert gas shielded arc or resistance welding process. No welding process that requires a welding flux shall be used. Only filler alloys complying with the governing code and specifications requirements shall be used. 4. All welds of structural members shall be performed by welders qualified in accordance with the governing code procedures. 5. Welding of aluminum shall be in accordance with nationally recognized standards. 6. Oxygen cutting of aluminum alloys shall not be permitted. 7. Where aluminum alloy parts are in contact with dissimilar metals (other than stainless, aluminized or galvanized steel) or absorbent building materials likely to be continuously or intermittently wet, the faying surfaces shall be painted or otherwise separated in accordance with the current aluminum specifications. 6. During erection, structural aluminum shall be adequately braced and fastened to resist dead, wind and erection loads. Fasteners 1. Screws shall be ITW Buildex screws per ICC report ESR-1976 or other equivalent screws with current ICC report. 2. Screws which are removed shall be replaced with a larger diameter screw where replacement is made into an existing hole. Replace all screws which strip out material. 3. Screws shall be spaced no closer than 5/8" o.c, and maintain a minimum free edge distance of 1/2", U.N.O. 4. Clip angles or flat clips used for attachment shall be a minimum of 33 mils, U.N.O. Size all clip angles and flat clips to maintain minimum screw spacing and edge distances as noted above. 5. All screws #8 and larger shall have a minimum head size of 5/16". All screws shall have sufficient length to ensure penetration into aluminum/steel by at least (2) full diameter threads. 6. All screws shall be a minimum of #8 self -tapping screws, U.N.O. 7. All anchors installed into concrete shall be Hilt! KB TZ expansion anchors (ESR-1917) or Hilt! HIT -RE 500-SD adhesive anchors (ESR-2322). All anchors installed into CMU shall be Hllli KB III expansion anchors (ESR-1385) or Hilt! HIT HY-70 adhesive anchors (ESR-2682). Approved equivalent anchors with current ICBO/ICC reports may be used at the contractor's discretion. 8. All bolts shall be installed as bearing -type connections with threads excluded from shear plane (type "x" connection), U.N.O. High -strength bolts shall be snug tightened using any AISC approved method and do not require special inspections unless noted otherwise. All bolts in slotted or oversize holes and all high -strength bolts shall be installed with washers. SPECIAL INSPECTION 1. All required special inspections shall be performed in accordance with the current accepted building code. Check with the local building department for required special inspections. 2. The special inspector shall be a qualified person who shall demonstrate competence, to the satisfaction of the local building department, for the inspection of the particular type of construction or operation requiring special inspection. 3. The special inspector shall inspect the work assigned for conformance with the approved contract drawings and specifications. The special inspector shall furnish inspection reports to the local building department, the FOR and other designated persons required by the governing building official. All discrepancies shall be brought to the immediate attention of the contractor for correction, and then if uncorrected in a reasonable period of time, the FOR and the building official shall be notified. The special inspector shall submit a final signed report stating whether the work requiring special inspection was, to the best of the inspectors knowledge, constructed in conformance with the approved plans and speclflcations and the applicable building code provisions 4. Inspectors shall inspect from an approved set of contract drawings, shop drawings shall not be used in lieu of the approved contract drawings for inspection purposes. 5. Certificate of approval regarding materials and inspection of prefabricated items shall be provided in accordance with the current accepted building code. 03.11.2016 HW Engineering Hongyu Wang, P.E., S.E. 10530 Hope Mills Drive Las Vegas, NV 89135 Phone: 702-202-0061 Fax: 702-221-9962 Email: hongyu@hwengineeringUSA.com www.hwengineeringUSA.com Rainier Wwbies, LW 18375 wr icke. S. Tuky&,WA 088 800-869-7162 Toll Free 425-251-1800 Phone 425-251-5065 Fax www.rainier.com Original design concepts are protected under Federal Copyright Laws and are the property of Rainier Industries, Ltd. Any reproduction of this design concept without written consent is expressly forbidden. ISO 9001:2000 REGISTERED ISO 14001: EMS - REGISTERED SPECIALTY CONTRACTOR -RAINIILO660P ELECTRICAL CONTRACTOR - RAINlIL948OF Woodman Consbuon 22828100th Ave W Endmonds, WA98036 Revisions REV. IDESIGNERI DATE A I Chad S 2/25/2016 yyetal Awning art gon Enaineerina Notes DrawingTllle - 366306-1-1 RI Job Number Issue Date / By PO.00 Sheet Number Deliverables anopy Proposed New Canopy Existing Trash Compactor Existing Ground Isometric View of Assembly 10 1210-0014 j RECT, Aluminum, 2" x 4" x 1/4" w all x 20' 20 1210-0011 ;SQ Tube, Aluminum, 1" x .110" Wall x 25' i 30 2" X 2" Alum Angle Angle, 6063-T52 Aluminum, 2" x 2" x 3/16", 16' 35 3" x 4" Steel Angle Angle, Steel, 3" x 4" x 1/4", 20' Length 37 3" Steel Pipe I Pipe, Steel, 3" SCH40, 21'-0" Length 4013-1/2" Steel Pipe 3 1/2" SCH40 Steel Pipe. 2T-0" Long 50I1110-0013 !Sheet, Steel, 4' x 8' x 1/4" 70� Nu- Ray NRM 1000 INu-Ray NRM-1000 Standing Seam Roofing 134-1/2" Length. Color: Deep Blue Sea i 75ITop Flashing `Top Flashing, Custom Bent 771Gable Flashing !Gable Flashing, Custom Bent 801 Gutter I !Model #24002025120. 5" x 10' Long K-Style Black Aluminum Gutter I 90lGutter End Caps :Model #5ENLBL & 5ENRBL. 5" Black Aluminum End Caps, (1 Left & 1 Right). 951 Dow nspout Model #24019025120, 2" x 3" x 10' BlackAluminum Downspout 100I Dow nspout Elbow Model #3AEBL. 2" x 3" Black Aluminum Dow nspout A Elbow File Name: Existing Wall Exisitng Concrete Wall Remainder of Roofing / Gutter Omitted for Canopy Structure Clarity Compactor guide rails to be extended to face of canopy to allow appropriate placement of unit Sheet Index # Drawing Title Affected Departments 1 Scope of Work 2 Site Plan 3 Plot Plan 4 Elevation View 5 End Views 6 Attachment Details 1 7 Attachment Details Cont. 1 8 Awning Assembly M 9 Awning Frame Iso M 10 Awning Frame Views M 11 Leg Details M Rainier Industries, Ltd 18375 Olympic Ave. S. Tukwila, WA 98188 800-869-7162 Toll Free 425-251-1800 Phone 425-251-5065 Fax wvvw.Rainier.com Original design concepts are protected under Federal Copyright Laws and are the property of Rainier Industries, Ltd. Any reproduction of this design concept without written consent is expressly forbidden. ISO 9001:2000 REGISTERED ISO 14001: EMS - REGISTERED SPECIALTY CONTRACTOR- RAINHI-0660P ELECTRICAL CONTRACTOR - RAINlIL948OF Woodman Construction REVISIONS REV. DESIGNER DATE Awning Part Metal Awning Part Description Scope of Work Drawing Title 366306-1-1 Rt Job umber Issue Date / By P 1.00 Sheet Number Plot Plan Scale: 1132" = 1'-0' man Construction\366306-1-1 - (1) Metal Marquee\Urawinq\Site Plan - RainierIndushies, Lid 18375 Ofyrrlpic Ave. S. Tuk*,WA 98188 800-869-7162 Toll Free 425-251-1800 Phone 425-251-5065 Fax www.rainier.com Original design concepts are protected under Federal Copyright Laws and are the property of Rainier Industries, Ltd. Any reproduction of this design concept without written consent is expressly forbidden. ISO 9001:2000 REGISTERED ISO 14001: EMS - REGISTERED SPECIALTY CONTRACTOR - RAIN11LO66QP ELECTRICAL CONTRACTOR - RAINlIL946QF Woodman Construon Revisions REV. IDESIGNERI DATE B I Chad S 4/27/2016 Canopy Metal Part Description Si ie 1. r�awmg I e 366306-1-1 RI Job Number Issue Date I By P2.00 Sheet Number Plot Plan of Assembly RAINIER Rainier Industries, Ltd 18375 Olympic Ave. S, Tukwila, WA 98188 800-869-7162 Toll Free 425-251-1800 Phone 425-251-5065 Fax www.Rainier.com Original design concepts are protected under Federal Copyright Laws and are the property of Rainier Industries, Ltd Any reproduction of this design concept without written consent is expressly forbidden. ISO 9001:2000 REGISTERED ISO 14001: EMS - REGISTERED SPECIALTY CONTRACTOR -RAINIILO66QP ELECTRICAL CONTRACTOR - RAINlIL998OF Woodman Construction REVISIONS Guide Rail Extensior per hauler request REV. DESIGNER DATE Awning Part Metal Awning 'rari D-COptiell Scope of Work Drawing Title 366306-1-1 RI Job Number Is— Dale / By File Name: P3.00 Sheet Number hrouna (In rronT oT Wall) tLeyaTIOn view oT Assemply r-XISTIng l-anCfeTe VVall Rainier Industries, Ltd 18375 Olympic Ave. S. Tukwila, WA 98188 800-869-7162 Toll Free 425-251-1800 Phone 425-251-5065 Fax www.Rainier.com Original design concepts are protected under Federal Copyright Laws and are the property of Rainier Industries, Ltd Any reproduction of this design concept without written consent is expressly forbidden. ISO 9001:2000 REGISTERED ISO 14001: EMS - REGISTERED SPECIALTY CONTRACTOR-RAINIIL0660P ELECTRICAL CONTRACTOR - RAINlIL996OF Woodman Construction REVISIONS REV. DESIGNER FDATE Awning Part Metal Awning Part Description Scope of Work Drawing Title 366306-1-1 R1 Job Number issue Date; By File Name: P4.00 Sheet Number ing Left Side of Assembly Proposed N 1364" Existing Concl (By umeis) Right Side of Assembly Cxlsnny IIUSII I-UITIPUUIUr (By Others) 03.11.2016 4�- Rainier Industries, Ltd 18375 Olympic Ave. S. Tukwila, WA 98188 800-869-7162 Toll Free 425-251-1800 Phone 425-251-5065 Fax www.Rciinier.com Original design concepts are protected under Federal Copyright Laws and are the property of Rainier Industries, Ltd. Any reproduction of this design concept without written consent is expressly forbidden. ISO 9001:2000 REGISTERED ISO 14001: EMS - REGISTERED SPECIALTY CONTRACTOR - RAINIIL066QP ELECTRICAL CONTRACTOR - RAINlIL940OF Woodman Construction REVISIONS REV. DESIGNER I DATE Awning Part Metal Awning Part Description Scope of Work Drawing Title 366306-1-1 RI Job Number Issue Date / By P5.00 Sheet Number Nu -Ray NRM 1000 Standing Seam Roofing 92240A640 - 0.375-16 S.S. Cap Screw w/ Locknut. (2) Per Leg Angle to Frame Connection Awning Rafter 3"x4"x 1/4"Thick Steel Angle Welded to Stem 3" Sch 40 Steel Pipe Stem Welded to Angle TYP. IV 92240A645 - 0.375in-16 S.S Cap Screw w/ Locknut. (1) Per Leg Connection 3-1/2" Sch 40 Steel Pipe Leg Welded to Baseplate —L Hilti KB-TZ 3/8" x 5" S.S Expansion Anchor --------- 2" Minumim Embedment I (2) Every Leg SECTION J-J - Leg Attachments SCALE 1 : 4 TYP. IV 4"x9"x 1/4"Thick Steel Baseplate Welded to Leg Existing Concrete Wall (By Others) Nu-Ray Stand 1"x 1" Awni Pul Awninc 2"x2"x3/16"T Welded to Top Bar L x 4 P IUrTI l op Dar Welded to Rafter Existing Wall Hollow CMU) Sy Others x 1.75" Tapcon :hor for CMU ry 24" O.C. 3/8" x 5" Long S.S All Thread w/ Hilti HY-70 Epoxy 2" Min. Emb. Every 24" O.C. Top Bar DETAIL N - Upper Awning, Flashing & Roofing Attachments SCALE 1 :4 03.11.2016 Rainier Industries, Ltd 18375 Olympic Ave, S. Tukwila, WA 98188 800-869-7162 Toll Free 425-251-1800 Phone 425-251-5065 Fax www.Rainier.com Original design concepts are protected under Federal Copyright Laws and are the property of Rainier Industries, Ltd. Any reproduction of this design concept without written consent is expressly forbidden. ISO 9001:2000 REGISTERED ISO 14001: EMS - REGISTERED SPECIALTY CONTRACTOR -RAIN11LO660P ELECTRICAL CONTRACTOR -RAINlIL948QF Woodman Construction I REVISIONS I REV.I DESIGNER I DATE Awning Metal Awning Part Description Scope of Work Drawing Title 366306-1-1 RI Job Number Date / By P6.00 File Name: Sheet Number Nu -Ray NRM 1000 Standing Seam Roofing 1"x 1" Purlins Welded to Awning Rafters Custom Bent 4" x 4" Eave Flashing 94058A542 - 0.25in - 14 x 1 in Sealing -Drilling Screw (1) Every 12" O.C. Amerimax 5" K-Style Gutter, Black Amerimax 2" x 3" Alum. Downspout (1) at Each end of Canopy Nu -Ray NRM 1000 Standing Seam Roofing 94058A542 - 0.25in - 14 x 1 in Sealing -Drilling Screw (1) Every 12" O.C. at Every Purlin 3/16 TYP. 2" x 4" Awning Rafter 2" x 4" Alum. Tube Wlded to Rafter DETAIL T - Boftom Gufter, Flashing and Roofinq Aftachments SCALE 1 : 2 )m Bent c3aoie riasning 94058A542 - 0.25in - 14 x 1 in Sealing -Drilling Screw (1) Every 24" O.0 End Rafter 2" x 4" End Rafter 03.11.2016 0 Rainier Industries, Ltd 18375 Olympic Ave. S. Tukwila, WA 98188 800-869-7162 Toll Free 425-251-1800 Phone 425-251-5065 Fax www.Rainier.com Original design concepts are protected under Federal Copyright Laws and are the property of Rainier Industries. Ltd. Any reproduction of this design concept without written consent s expressly forbidden. ISO 9001:2000 REGISTERED ISO 14001: EMS - REGISTERED SPECIALTY CONTRACTOR - RAINIIL0660P ELECTRICAL CONTRACTOR - RAINlIL948QF Woodman Construction Awning Metal Awning Part Description Scope of Work Drawing Title 366306-1-1 RI Job Number Issue Date / By File Name: P7.00 Sheet Number Rainier Industries, Ltd 18375 Olympic Ave. S. Tukwila, WA 98188 800-869-7162 Toll Free 425-251-1800 Phone 425-251-5065 Fax www.Rainier.com Original design concepts are protected under Federal Copyright Laws and are the property of Rainier Industries, Ltd Any reproduction of this design concept without written consent is expressly forbidden. ISO 9001:2000 REGISTERED ISO 14001: EMS - REGISTERED SPECIALTY CONTRACTOR - RAINIILO660P ELECTRICAL CONTRACTOR - RAINIIL9460F Woodman Construction I REVISIONS I A I Chad S 1 2/22/2016 Awning Metal Awning Part Description Awning Assembly Drawing Title 366306-1-1 _ RI Job Number Date / By File Name: Sheet Number # QTY 1 2 2 9 3 1 4 6 File Name: DESCRIPTION LENGTH ANGLEI ANGLE2 4 x 2 Rect x .125 Wall 184 1 /4" 0.00 0.00 1 " x 1 " Alum. Tube 130 7/8" 19.54 19.54 LS 2.00 x 2.00 x 0.187 184 1 /4" 0.00 0.00 1 " x I " Alum. Tube 184 1 /4" 0.00 0.00 03.11.2016 Rainier Industries, Ltd 18375 Olympic Ave. S. Tukwila, WA 98188 800-869-7162 Toll Free 425-251-1800 Phone 425-251-5065 Fax www.Rainier.com Original design concepts are protected under Federal Copyright Laws and are the property of Rainier Industdos, Ltd Any reproduction of this design concept without written consent is expressly forbidden. ISO 9001:2000 REGISTERED ISO 14001: EMS - REGISTERED SPECIALTY CONTRACTOR -RAINIIL056QP ELECTRICAL CONTRACTOR - RAINlIL9460F Woodman Construction REVISIONS A I Chad S 1 2/22/2016 Awning Part Metal Awning Pari Description Awning Isometric Drawing Title 366306-1-1 RI Job Number Issue Date / By P9.00 Sheet Number 6" File Name CD c 4" T MICO N LO 00 co 10 N 10 U r Top View of Frame 126" Right End of Frame l MCP � O 2" 4" 2" CO 03.11.2016 Rainier Industries, Ltd 18375 Olympic Ave. S. Tukwila, WA 98188 800-869-7162 Toll Free 425-251-1800 Phone 425-251-5065 Fax www.Rainier.com Original design concepts are protected under Federal Copyright Laws and are the property of Rainier Industries, Ltd. Any reproduction of this design concept without written consent is expressly forbidden. ISO 9001:2000 REGISTERED ISO 14001: EMS - REGISTERED SPECIALTY CONTRACTOR - RAINIIL0660P ELECTRICAL CONTRACTOR - RAINlIL9460F Woodman Construction REVISIONS A I Chad S 2/22/2016 Awning Part Metal Awning Part Description Awning Views Drawing Title 366306-1-1 RI Job Number Issue Date I By Pl 0.00 Sheet Number 2 16"TYI . File Name: 841" 4 1 ,1 4 Front View of Bottom Leq TQ Y (61 91, Top View of Bottom Leg 7„ 6 Front View of Top Leg TY 6 f 4" v7 o 46272 cis (CIs-rVERF'G�� 510NA1. F� 03.11.2016 Rainier Industries, Ltd 18375 Olympic Ave. S. Tukwila, WA 98188 800-869-7162 Toll Free 425-251-1800 Phone 425-251-5065 Fax www.Rainier.com Original design concepts are protected under Federal Copyright Laws and are the property of Rainier Industries, Ltd. Any reproduction of this design concept without written consent is expressly forbidden. ISO 9001:2000 REGISTERED ISO 14001: EMS - REGISTERED SPECIALTY CONTRACTOR -RAINIIL05SOP ELECTRICAL CONTRACTOR - RAINlIL948OF Woodman Construction REVISIONS A Chad S 2/22/2016 Awning Part Metal Awning Part Description Leg Details Drawing Tille 366306-1-1 RI Job Number Issue Date / By P 1 1.00 Sheet Number