PLN2006-140 borgen plt.doc
Name: BORGEN File No.: PLN2006-140
RD
Reviewed by: Vicinity: 7718 203 ST SW
Engineering Division date
Provide 10.0 foot street dedication to the City of Edmonds X
Provide all easements as needed. X
All lots shall share a private access road/driveway X
Private access easements shall be 15.0 feet in width X
rd
203 St SW to be widened to provide for a minimum 12’ X
travel lane from the painted centerline to the face of curb.
Construct 18” concrete curb and gutter along the property X
frontage. Curb/gutter alignment to be consistent with
surrounding area.
Private access road shall be paved a minimum of 15.0’ wide X
plus 18” asphalt thickened edge. 6” concrete extruded curb
may be used
Slope of private access road/driveway shall not exceed 14%. X X
Provide on-site turn around to City Standards. X
Construct 5’ wide sidewalk along property frontage. X
N/A
N/A
Install 4” Storz adapter on existing fire hydrant. X
Provide water service to each lot. X X
Connect to public water system. X X
Provide new sanitary sewer service to each lot X
Connect to public sewer system X X
C:\\Users\\mcadmin\\AppData\\Local\\Temp\\PLN2006-140 borgen plt.doc_154052\\PLN2006-140 borgen plt.doc
revised:
11/15/05
C:\\Users\\mcadmin\\AppData\\Local\\Temp\\PLN2006-140 borgen plt.doc_154052\\PLN2006-140 borgen plt.doc
revised: 11/15/05
Provide storm sewer service to all proposed lots. X
Construct storm detention system sized to provide adequate X
capacity for proposed single family dwelling and access
improvements in accordance with ECDC 18.30.
Connect to Public Storm system X X
Connect all new impervious surfaces to detention system. X X
Required for all new services X X
Submit a grading plan as part of engineered site plan. X X
Grading for foundations to be included with the building
permit only.
All signs shall be vinyl letters and to City Stds. No silk screen X
signs will be permitted
Provide Fire and aid address sign X
Provide “ Access Ends” X
N/A
Required for all utility construction. X X
a) Plat showing lots, easements, legals, survey information X X
b) Legal documents for each lot X
c) Field stake lot corners (by professional surveyor) X
d) Field stake utility stubs at property lines. X
e) Clustered mailbox location per Postmaster X
f) Maintenance agreements X
C:\\Users\\mcadmin\\AppData\\Local\\Temp\\PLN2006-140 borgen plt.doc_154052\\PLN2006-140 borgen plt.doc
revised: 11/15/05
( NA ) X
a) Storm System Development charge (access only)
b) Storm System Development charge (sfr) X
$428/lot
c) Sewer LID fees to be paid in full X
d) Sewer Connection fee (new lots only) X
$730/lot
e) Water meter fee (based on ¾”) X
$550/meter
f) Water Connection fee (new lots only) X
$908/lot
$ X
g) Traffic Impact Fee $840.72/lot
$860X
h) Plan Review fee
$TBD X
i) Plat inspection fee (2.2% of improvement costs)
ENGINEERING PROGRAM MANAGER, CITY OF EDMONDS DATE
The Engineering requirements have been completed and the subdivision can be recorded.
Authorized for recording by: Date:
C:\\Users\\mcadmin\\AppData\\Local\\Temp\\PLN2006-140 borgen plt.doc_154052\\PLN2006-140 borgen plt.doc
revised: 11/15/05