Loading...
pln20070076 Thuesen 3-Lot SP civil review.pdfPLN20070048 Wichers SP, Civil Review City of Edmonds % 121 5TH AVENUE NORTH • EDMONDS, WA 98020 • (425) 771-0220 FAX(425) 771-0221 Website: www.ci.edmonds.wa.us DEVELOPMENT SERVICES DEPARTMENT Planning • Building • Engineering Civil Plan Review Comments Subdivision Application #: PLN20070076 Date: April 9, 2008 Project Name/Address: Thuesen 3-lot SP / 509 9th Ave N Contact Person/Address, Fax or E-mail: Eric Thuesen / ericthuesen@verizon.net Reviewer: Jeanie McConnell Division: Engineering During review of the civil drawings for the proposed subdivision it was found that the following information, corrections, or clarifications will need to be addressed. Please resubmit 3 copies of the revised civil drawings and associated documents with a written response to each item to an Engineering Technician. Please contact me at 425-771-0220 or by e-mail at mcconnell@ci.edmonds.wa.us if you have specific questions regarding these plan corrections. GENERAL 1. Please submit a cost estimate that includes those items bonded for under your original bond, plus any additional items that have been added specific to the development of the 3-lot short plat. Please remember to provide an itemized cost estimate for both on -site and off -site (right-of-way) improvements, including traffic control. SHEET 1 of 3 — DEVELOPMENT PLAN 1. A small portion of the driveway serving Lot 2 is shown on Lot 3. Please revise plans accordingly. 2. Please add a note to the civil plans addressing the relocation or removal of the shed that encroaches on the subject property. 3. The two notes regarding the "Ex. pad for future single family residence" gives the implication that there is physically a concrete or other type of pad on site when the area has just been graded and vegetated. Please revise the civils to state something to the affect of "future building area for SFR" instead of "pad". 4. The 15' ingress & egress easement should only be for the benefit of lot 2. Lot 1 takes access off 9th Ave N. Please revise the plans accordingly. 5. The 20' utility easement, where located on Lot 3 is for the benefit of Lots 1, 2 & 3. Where located on Lot 2, the easement is only for the benefit of Lot 1. Please revise the plans accordingly. DATE E-MAILED 4/9/08 PAGE(s) 1 of 2 PLN20070048 Wichers SP, Civil Review 6. The civils approved on August 10, 2007 for the two lot short plat at this site show a retaining wall along the southerly edge of the access road. The wall is still called out on Sheet 2 of this submittal, but has not been shown on this sheet. Please either show the wall as new or existing on this plan sheet and provide top and bottom of wall elevations. It is my understanding that the wall has not yet been constructed. SHEET 2 of 3 — CLEARING & GRADING PLAN & SWPPP 1. Please note on the plans that the topography contours provided are based on existing conditions, not necessaryily original grades. 2. Please provide grading quantities — both cut & fill — on this plan sheet. DATE E-MAILED 4/9/08 PAGE(s) 2 of 2