Loading...
PLN20150036 Phase 2 Staff Report.pdf"'C. 18y., CITY OF EDMONDS 121 5th Avenue North, Edmonds WA 98020 Phone: 425.771.0220 • Fax: 425.771.0221 • Web: www.edmondswa. DEVELOPMENT SERVICES DEPARTMENT • PLANNING DIVISION PLANNING DIVISION'S REPORT & RECOMMENDATION TO THE ARCHITECTURAL DESIGN BOARD "PHASE 2" DISTRICT -BASED DESIGN REVIEW Project: New 9-Unit Residential Building and Minor Improvements to Existing Mixed -Use Building File Number: PLN20150036 Date of Report: October 8, 2015 Staff Contact: �= ,J�n Machuga, ssociate Planner Public Hearing: Wednesday — November 4, 2015 at 7:00 P.M. Edmonds Public Safety Complex: Council Chambers 250 5th Avenue North, Edmonds WA 98020 I. PROJECT PROPOSAL Steve Butterfield of TGB Architects has submitted a land use application on behalf of GBH Holdings LLC for design review of a new 9-unit residential building and minor architectural improvements to an existing mixed -use building located at 303 and 311 Edmonds Street (Tax Parcel No. 00434202600102). The project site is approximately 7,050 square feet. The eastern portion of the site contains an existing two-story building addressed 311 Edmonds St., which contains an office on the ground floor and four residential units on the upper floor. The western portion of the site is currently an undeveloped gravel area that is occasionally used for parking, but is not striped for such. The proposed 9-unit residential building will be located on the currently vacant western portion of the site. The site is located within the Downtown Business (BD2) zone (Exhibit 1, Attachment 1). As noted at Phase 1 of this hearing on September 2, 2015, projects within the Downtown Business zones are subject to district -based design review under the regulations of Edmonds Community Development Code (ECDC) Chapter 20.12. According to ECDC 20.01.003 and 20.12.010, district -based design review applications that trigger SEPA review are Type III-B decisions, which require a two-phase public hearing and design decision by the Architectural Design Board (ADB). During the September 2nd meeting, the hearing was continued until November 4, 2015. GBH Holdings LLC Phase 2 Design Review File No. PLN20150036 According to ECDC 20.12.005.13, the purpose of continuing the hearing is to allow the applicant to design or redesign the initial concept to address the input of the public and the ADB by complying with the prioritized design guideline checklist criteria. The Phase 1 project plans are included for reference (Exhibit 1, Attachment 4 and Exhibit 2), and the Phase 2 project plans are provided within Exhibit 5. At the Phase 2 hearing, the ADB will complete their review of the design of the project and make the final decision on the design proposal at the conclusion of the Phase 2 of the hearing. The following Exhibits are included with this Phase 2 staff report: 1. Phase 1 Staff Report and Attachments 1-12, dated August 26, 2015 2. Revised Phase 1 Project Plans, received September 1, 2015 3. Staff's Phase 1 Presentation of September 2, 2015 4. Minutes for Phase 1 of the Public Hearing of September 2, 2015 5. Phase 2 Project Plans, received October 22, 2015: • General Information & Site Plan (Al) • First Floor Plan (A2) • Second & Third Floor Plan (A3) • Lighting Plans (A4) • Exterior Elevations (A5) • Vicinity Map • Bird's Eye Perspective • Approach from East Edmonds St. • 303 Entry Perspective • Approach from West Edmonds St. • Approach from North 3rd Ave. • Materials Board 1 • Materials Board 2 • Preliminary Grading and Drainage Plan (C3.1) • Landscape Plan (L-1.0) 6. Applicant's Response Letter, received October 28, 2015 7. SEPA Determination of Nonsignificance (DNS) and Environmental Checklist 8. Public Notice Materials for SEPA DNS and Courtesy Notice of Continued Hearing 9. Public Comment Letter from Barbara and Patrick Marker 10. Technical Review Committee Comments Page 2 of 28 GBH Holdings LLC Phase 2 Design Review File No. PLN20150036 II. FINDINGS & CONCLUSIONS A. NEIGHBORHOOD CHARACTERISTICS The subject site is located at the northeastern corner of the intersection of 3rd Avenue North and Edmonds Street. As can be seen on the Zoning and Vicinity Map (Exhibit 1, Attachment 1), the site is located on the northern edge of the downtown commercial core as the area transitions to residential uses. The parcel itself is zoned Downtown Business, BD2. The immediately adjacent properties to the north and south are also zoned BD2 while those to the east are zoned BD5 and those to the west are zoned Multiple Residential, RM-1.5. Further to the north of the subject site beyond the immediately adjacent BD -zoned properties are properties within the Single -Family Residential, RS-6 zone. Development in the vicinity includes a mix of commercial and both single-family and multi -family residential uses. The Edmonds Center for the Arts, which is in the Public Use, P, zone is also located within the vicinity of the site. B. PUBLIC NOTICE AND COMMENTS A "Notice of Application and Public Hearing" was issued on August 19, 2015. The notice was posted at the subject site, Public Safety Complex, Development Services Department, and at the Library. The notice was also mailed to property owners within 300 feet of the site and published in the Everett Herald. Those notice materials are included as Attachment 12 of Exhibit 1. Since the hearing was continued to a date certain during Phase 1 of the process, additional public notice of Phase 2 of the hearing was not required. However, a "Courtesy Notice of Continued Public Hearing" (Exhibit 8) was included with the Notice of SEPA Determination of Nonsignificance. This notice was published in the Herald Newspaper, posted at the subject site, as well as the Public Safety Complex, Development Services Department, and the Library on October 20, 2015. It was also mailed to property owners within 300 feet of the site and to the agencies listed on the determination (Exhibits 7 and 8). The City has complied with the noticing provisions of ECDC 20.03. One written public comment letter was received during review of the subject proposal from Barbara and Patrick Marker (Exhibit 9). Mr. and Mrs. Marker addressed concerns related to the lack of on -site parking for the project. Staff Response: As addressed in Section F.2 of this report, parking within the Downtown Business (BD) zones is regulated in ECDC 16.43. Pursuant to ECDC 16.43.030.D, no parking is required for any commercial floor area of permitted uses located within the BD2 zone and no parking is required for any floor area in any building with a total building footprint of less than 4,800 square feet. As indicated on the Phase 2 project plans (Exhibit 5), both the existing building and the proposed building have footprints of well under 4,800 square feet. Thus, no on -site parking is required for the proposed project. Page 3 of 28 GBH Holdings LLC Phase 2 Design Review File No. PLN20150036 C. TECHNICAL REVIEW COMMITTEE COMMENTS The Phase 1 portion of the subject application was reviewed and evaluated by the City Engineering Division, Building Division, and Snohomish County Fire District #1. Initial comments by these reviewers were included with the August 26, 2015 report to the ADB (Exhibit 1, Attachments 9-11). These reviewers also reviewed the Phase 2 submittal. In response to their review of the Phase 2 submittal materials, the Engineering Division provided a memorandum dated October 23, 2015, which included the following comments: 1. The screening of the stairway on the east side of the existing building shall not extend further south than the face of the building to prevent obscuring pedestrians from cars exiting the alley. 2. As shown on the Preliminary Grading and Drainage plan, Sheet C3.1, three street trees shall be required along Edmonds St at 30' on center spacing per the City of Edmonds Street Tree plan. Only two trees are shown on the architectural plans. 3. All impervious surfaces shall be discharged to the onsite stormwater management system. There is no "variance" required for the location of the stormwater management system as stated on the Preliminary Grading and Drainage plan. Instead, verification of the absence of a surcharge being placed on the system along with other stormwater management requirements will be reviewed by the Engineering Division at the time of the building permit submittal. 4. The awning on the existing building is shown projecting over the public right of way. A Street Use permit shall be required subject to Edmonds Community Development Code Chapter 18.70. The first two comments of the Engineering Division's October 23, 2015 memorandum have been added as recommended conditions of approval since they impact the design review of the project. The last two comments were provided by the Engineering Division as notes to the applicant, so these have not been added as specific conditions of approval, but they will need to be addressed at the time of building permit review. The Building Division had no further comments from those provided in their memo dated August 14, 2015 (Exhibit 1 Attachment 10), which will need to be addressed at the time of building permit review. Snohomish County Fire District #1 had no comments. All Phase 2 review comments are included for reference in Exhibit 10. All three groups noted that a detailed review of the entire scope of work will take place during the building permit review process. Additional comments may be provided by other reviewing groups at that time. D. COMPREHENSIVE PLAN It should be noted that the City's 2015 Comprehensive Plan update was adopted on July 28, 2015. This application is subject to the 2015 Comprehensive Plan since it was not vested to the previous Comprehensive Plan. The Comprehensive Plan designation for this site is "Downtown Mixed Commercial," and the site is also within the "Downtown/Waterfront Activity Center." Page 4 of 28 GBH Holdings LLC Phase 2 Design Review File No. PLN20150036 Goals and policies from the City of Edmonds Comprehensive Plan related to this project include: Goals for Downtown Mixed Commercial. To encourage a vibrant downtown, first floor spaces should be designed with adequate ceiling height to accommodate a range of retail and commercial uses, with commercial entries at street level. Buildings can be built to the property line. Building heights shall be compatible with the goal of achieving pedestrian scale development. The first floor of buildings must provide pedestrian weather protection along public sidewalks. Design guidelines should provide for pedestrian -scale design features, differentiating the lower, commercial floor from the upper floors of the building. The design of interior commercial spaces must allow for flexible commercial space, so that individual business spaces can be provided with individual doorways and pedestrian access directly to the public sidewalk. When the rear of a property adjoins a residentially - designated property, floor area that is located behind commercial street frontage may be appropriate for residential use. Where single family homes still exist in this area, development regulations should allow for "live -work" arrangements where the house can accommodate both a business and a residence as principal uses. (2015 Comprehensive Plan, page 56) General design objectives addressing site design, building form and building fagade are provided in pages 123-125 of the Comprehensive Plan, and additional design goals and policies specific to the Downtown/Waterfront Activity Center are provided in pages 125-127. The Phase 2 project plans (Exhibit 5) have been reviewed for compliance with the applicable objectives. An analysis of the proposal's compliance with the applicable Comprehensive Plan design objectives follows. Design Objectives for Site Design. The development of parking lots, pedestrian walkways and landscaping features is an integral part of how a building interacts with its site and its surrounding environment. Good design and site planning improves access by pedestrians, bicycles and automobiles, minimizes potential negative impacts to adjacent development, reinforces the character and activities within a district and builds a more cohesive and coherent physical environment. A.1 Vehicular Access. Reduce the numbers and width of driveways (curb cuts) in order to improve pedestrian, bicycle and auto safety. Comments: The proposal does not include on -site parking and, therefore, does not include any curb cuts for vehicular access off of 3rd Ave. N nor off of Edmonds Street. Vehicular access to the trash and recycling enclosure will be off of the existing alley adjacent to the eastern side of the site. A.2 Layout of Parking. Locating buildings in proximity to the street to facilitate direct pedestrian access and help define the street edge. Parking should be placed to the side and rear. Comments: The proposed building is located adjacent to the street corner and is oriented to allow direct pedestrian access off of Edmonds Street. No on -site parking is proposed. Page 5 of 28 GBH Holdings LLC Phase 2 Design Review File No. PLN20150036 A.3 Connections On- and Offsite. Design site access and circulation within and between sites to encourage linkages for pedestrians, vehicles, and bicycles. Special attention should be paid to providing and improving connections to transit. Comments: The proposed building will immediately improve the streetscape and enhance pedestrian activity on both 3rd Avenue North and Edmonds Street by covering an existing underutilized gravel parking area with a functional building. The proposed building will be located close to the sidewalk edge at this intersection. Both the proposed building and the existing building will provide pedestrian access directly off of Edmonds Street. No changes are proposed to the existing bus stop located near the western side of the site. A.4 Building Entry Location. Building entries should be configured to provide clear entry points to buildings, be oriented to pedestrian walkways/pathways, and support the overall intent of the streetscape environment. Space at the entry for gathering or seating is desirable for residential or mixed use buildings. Comments: As indicated on the Phase 2 project plans (Exhibit 5), the main entry to the proposed building will be recessed on the southern side of the building, creating an entry courtyard. This entry will be directly linked via a walkway to the sidewalk on Edmonds Street. The existing building will retain its main entry directly onto the sidewalk on Edmonds Street in addition to an existing exterior stairwell that provides access to the upper floor directly from the sidewalk on Edmonds Street. A courtyard walkway will be provided between the two buildings allowing tenants to access a bicycle rack and the trash/recycling area. The proposal should contribute to creating an active, lively street -edge and a pedestrian friendly environment. A.5 Setbacks. Create and maintain the landscape and site characteristics of each neighborhood area and provide a common street frontage tieing each site to its neighbor. Setbacks should be appropriate to the desired streetscape, providing for transition areas between public streets and private building entries where a variety of activities and amenities can occur. Comments: The subject site has no minimum required setbacks. The proposed building will be constructed close to the western property line, and although the building will be set back from the southern property line, the patios and decks above will be constructed up to the southern property line. The recessed main entry to the new building will provide a pedestrian -friendly scale to the building by creating an entry courtyard. A.6 Open Space. For residential settings, create green spaces to enhance the visual attributes of the development and provide places for interaction, play, seating, and other activities. Comments: The proposal does not have an open space requirement pursuant to ECDC 16.43.030.E; however, the project does include patio areas and decks for each of the new residential units. Additionally, the recessed entry creates a small courtyard area, and a walkway/courtyard area is provided between the existing and proposed buildings as well. Page 6 of 28 GBH Holdings LLC Phase 2 Design Review File No. PLN20150036 A.7 Building/Site Identity. Improve pedestrian access and way finding by providing variety in building forms, colors, materials and individuality of buildings. Comments: As can be seen on the Phase 2 project plans (Exhibit 5), the proposed building is slightly larger in scale than the existing building; however, the proposal incorporates similar colors and materials to provide a linkage between the two buildings without making them match exactly. Although the existing building does not incorporate much modulation or variety in materials, the proposed building uses a variety of forms, colors and materials. The building uses this variety along with modulation to create a feel that reflects the patterns of some of the older buildings in the downtown area. For example, elements of the building are divided into approximate 20- to 30-foot wide lengths which allude to historic development patterns on narrow downtown lots. A.8 Weather Protection. Provide covered walkways and entries for pedestrian weather protection. Comments: A canopy is proposed on the existing building over the sidewalk on Edmonds Street. Additionally, a canopy is proposed over a portion of the recessed entry courtyard on the new building. These canopies will provide weather protection for pedestrians entering and exiting the buildings. A.9 Lighting. Provide adequate and appropriate illumination in all areas used by automobiles, bicycles and pedestrians — including building entries, walkways, parking areas, circulation areas and other open spaces — to support activity and security. Comments: As shown on the lighting plan in Exhibit 5, several types of lighting are proposed for the buildings and site including surface mounted up/down lights, ceiling mounted down lights, shielded directional bollard lights, floodlights, and surface mounted directional lights. The pedestrian entrances will be emphasized with lighting, and lighting will also be used to illuminate the main entry courtyard of the proposed building and the courtyard/walkway between the two buildings. A.10 Signage. Encourage signage that provides clear information and direction for properties and businesses while preventing the streetscape from becoming cluttered. Encourage the use of graphics and symbols in signage to support the city's emphasis on uniqueness and the arts. Comments: Signage was not proposed as part of this application. Any proposed signage will be reviewed for compliance with Chapter 20.60 ECDC at the time of the associated building permit application review. A.11 Site Utilities, Storage, Trash and Mechanical Systems. Minimize the noise, odor and visual impacts of utility systems using such features as landscaping, building forms, or integrated design. Comments: A new trash and recycling enclosure will be provided at the northeastern corner of the site, which will be accessed by tenants from the courtyard/walkway between the two buildings and accessed by haulers from the adjacent alley to the east Page 7 of 28 GBH Holdings LLC Phase 2 Design Review File No. PLN20150036 of the site. Additionally, a heat pump will be located on the northern side of the existing building, which will be screened by the building itself, the trash enclosure, landscaping, and a fence along the northern property line. A transformer is proposed on the east side of the existing building. No specific screening of this transformer is indicated on the plans; however, the transformer will be somewhat screened from view along Edmonds Street by the proposed stair enclosure. A.12 Integrating Site Features. Integrate natural landscape features and unique landforms — such as rocky outcroppings or significant trees — into site design whenever possible. Comments: The subject site is relatively level and currently contains very limited existing vegetation. No unique natural features or landforms were observed. A.13 Landscape Buffers. Use landscaping and/or other features such as fences to maintain privacy and create a visual barrier between incompatible uses. These buffering techniques should also be used to soften hard edges (such as the perimeters of parking lots) and reinforce pedestrian ways and circulation routes. Native plants and rain gardens should be promoted as alternatives to lawns and runoff retention areas. Comments: The Phase 2 project plans (Exhibit 5) indicate a 6-foot cedar fence along the northern property line to provide privacy between the subject site and the adjacent property to the north. Lower fences are indicated adjacent to 3rd Ave. N and Edmonds St. in order to provide some privacy for residents of the ground floor of the new building while still providing a visual connection between the site and the street front. As indicated on the landscape plan, a variety of trees, shrubs, and other vegetation will be utilized to help provide further privacy and visual interest to the site. Design Objectives for Building Form. Building height and modulation guidelines are essential to create diversity in building forms, minimize shadows cast by taller buildings upon the pedestrian areas and to ensure compliance with policies in the city's Comprehensive Plan. Protecting views from public parks and building entries as well as street views to the mountains and Puget Sound are an important part of Edmonds character and urban form. A.14 Building Form. Encourage new construction to avoid repetitive, monotonous building forms. Comments: A variety of elements are employed to avoid repetitive, monotonous building forms in the new building. This includes the use of a brick base around much of the first floor of the building, the use of decks on the second and third floors, and modulating the facades vertically. Additionally, a variety of materials and colors will be utilized to increase the visual interest of the proposed building and to help break up its mass. The use of a recessed main entry courtyard with a canopy over a portion of the courtyard helps to identify the main building entry and provide human scale elements to the new building. Page 8 of 28 GBH Holdings LLC Phase 2 Design Review File No. PLN20150036 A.15 Massing. Reduce the apparent bulk and mass of buildings by encouraging human scale elements in building design and/or by subdividing building masses vertically or horizontally. Comments: The same techniques discussed above regarding the building form also contribute to breaking up the apparent mass of the proposed building. The planter boxes on the southern side of the new building as well as the covered entry courtyard and hanging flower baskets at the main entry provide human scale elements to the new building. Following the proposed removal of the existing single -story bumpout on the western side of the existing building, this building will have no modulation and will appear as a box with little visual interest. The applicant has proposed a painted belt course, canopy, planter boxes, and hanging flower baskets along the southern facade of the existing building, which will help to break up the mass of this facade and will bring human scale elements into the street -facing side of the existing building. The remaining facades of the existing building are still fairly blank in appearance since the majority of the architectural improvements proposed to the existing building are on the southern fagade. Staff has included a recommended condition for the applicant to wrap the painted belt course from the southern building fagade around the entire building in order to help break up the mass of the eastern, western, and northern facades. Additionally, the applicant has proposed a screening wall to help enhance the look of the exterior stairwell on the eastern side of the existing building. The proposed screening wall, however, is approximately 10 feet tall, which causes this screening wall to become a large blank wall itself. Staff recommends that the screening wall around the stairs be designed at an angle so that it will be triangular -shaped to follow the shape of the stairs. This will provide adequate screening of the stairs without creating a large blank wall. A recommended condition has been added to this effect. A.16 Roof Modulation. Use roof forms to help identify different programs or functional areas within the building and support differentiation of building form and massing. Roof design, in combination with wall modulation, can allow for additional light to enter buildings or pedestrian spaces. Comments: The roof on the existing building is flat, and no changes are proposed to the roof on the existing building. As indicated on the Phase 2 project plans (Exhibit 5), the proposed building will employ a combination of a flat roof and portions that are sloped as a "shed roof" with the eaves on the sloped portions projecting out past the exterior building facades. The slight variation in roof pitch on the proposed building will help to break up the mass of the building and provide visual interest. A.17 Wall Modulation. Variation in materials, decorative elements, or other features should be employed to support pedestrian scale environments and streetscapes, or to help break up large building masses to keep in scale with the surrounding environment. Page 9 of 28 GBH Holdings LLC Phase 2 Design Review File No. PLN20150036 Comments: As shown on the elevation views in Exhibit 5, all four sides of the proposed building are well -modulated. Although the existing building does not incorporate much modulation or variety in materials, the proposed building uses a variety of forms, colors and materials. The proposed building uses this variety in colors and materials along with vertical modulation to create a feel that reflects the patterns of some of the older buildings in the downtown area. For example, elements of the building are divided into approximate 20- to 30-foot wide lengths which allude to historic development patterns on narrow downtown lots. The canopies over the main building entries and the use of a brick veneer base around much of the lower floor of the proposed building will help to support a pedestrian scale environment. The low fences around the patios on the lower floor of the proposed building will provide some privacy to tenants while maintaining a connection between the building and the streetscape. Design Objectives for Building Facade. Building facade objectives ensure that the exterior of a building — the portion of a building that defines the character and visual appearance of a place — is of high quality and demonstrates the strong sense of place and integrity valued by the residents of the City of Edmonds. A.18 Building Facade Design. Encourage building fagades that reinforce the appearance and consistency of streetscape patterns while supporting diversity and identity in building design. Comments: The facades of the proposed building include vertical and horizontal differentiation that reinforces a human scale streetscape. The upper floors are modulated using decks, materials and colors. The ground floor facade is also divided vertically in widths that reflect historic patterns of development in the downtown area. A.19 Window Variety and Articulation. Use window size and placement to help define the scale and character of the building. Use the organization and combinations of window types to reinforce the streetscape character or to provide variation in a facade, as well as provide light and air to the building interior. Comments: No changes are proposed to the existing windows on the existing building. A variety of window sizes are proposed for the new building in order to provide visual interest to the building. The proposed window sizes and style are consistent with that of typical multi -family development. A.20 Variation in Facade Materials. Employ variation in materials, colors or design elements on building facades to help define the scale and style of the structure. Variation in facade materials can help reduce the apparent bulk of larger buildings while allowing variety and individuality of building design. Comments: A variety of materials will be utilized for the completed project including brick, CM4 block, and cementitious siding. The entry canopies will be metal. Additionally, cedar horizontal fencing will be utilized throughout the site. This combination of materials will contribute to an attractive appearance. Additional features include residential decks, steel planter boxes, and hanging flower baskets. Page 10 of 28 GBH Holdings LLC Phase 2 Design Review File No. PLN20150036 Although the existing and proposed building will not employ all of the same building materials, the proposal incorporates the same color palette throughout as well as consistent planter boxes, flower baskets, and fencing, which will provide a linkage between the two buildings without making them match exactly. In addition to the general design objectives discussed above, the following supplemental design objectives are applicable to the Downtown/Waterfront Activity Center: Urban Design Goal B: Downtown/Waterfront Activity Center. Design objectives and standards should be carefully crafted for the Downtown/Waterfront Activity Center to encourage its unique design character and important place -making status within the city. B.1 Vehicular Access and Parking. Driveways and curb cuts should be minimized to assure a consistent and safe streetscape for pedestrians. When alleys are present, these should be the preferred method of providing vehicular access to a property and should be used unless there is no reasonable alternative available. Configuration of parking should support a "park and walk" policy that provides adequate parking while minimizing impacts on the pedestrian streetscape. Comments: The proposal does not include on -site parking and, therefore, does not include any curb cuts for vehicular access off of 3rd Ave. N nor off of Edmonds Street. Vehicular access to the trash and recycling enclosure will be off of the existing alley adjacent to the eastern side of the site. B.2 Pedestrian Access and Connections. Improve pedestrian access from the street by locating buildings close to the street and sidewalks, and defining the street edge. Cross walks at key intersections should be accentuated by the use of special materials, signage or paving treatments. Transit access and waiting areas should be provided where appropriate. Comments: The proposed building will be constructed close to the western property line, and although the building will be set back from the southern property line, the patios and decks above will be constructed up to the southern property line. The recessed main entry courtyard will provide a direct connection from the building to the sidewalk along Edmonds Street. The existing building will retain its main entry directly onto the sidewalk on Edmonds Street in addition to an existing exterior stairwell that provides access to the upper floor directly from the sidewalk on Edmonds Street. The minor architectural improvements proposed to the existing building (i.e. canopy on the southern side of the building, planter boxes, and hanging flower baskets) will help to identify this entry. No changes are proposed to the existing bus stop located near the western side of the site. B.3 Building Entry Location. Commercial building entries should be easily recognizable and oriented to the pedestrian streetscape by being located at sidewalk grade. Comments: The entry to the existing building is located at sidewalk grade and is adjacent to the sidewalk along Edmonds Street. A recessed entry courtyard will help to identify the main entry to the proposed building. Canopies over the main entry on both the existing and proposed buildings and hanging flower baskets will help to Page 11 of 28 GBH Holdings LLC Phase 2 Design Review File No. PLN20150036 further identify the locations of these entries and will provide weather protection for pedestrians entering and exiting the buildings. B.4 Building Setbacks. Create a common street frontage view with enough repetition to tie each site to its neighbor. Encourage the creation of public spaces to enhance the visual attributes of the development and encourage outdoor interaction. In the Waterfront area west of the railroad, buildings should be set back from the waterfront to preserve and provide a buffer from existing beach areas. In the Waterfront area, site layout should be coordinated with existing buildings and proposed improvements to provide views of the water, open spaces, and easy pedestrian access to the beach. Comments: The subject site has no minimum required setbacks. The proposed building will be constructed close to the western property line, and although the building will be set back from the southern property line, the patios and decks above will be constructed up to the southern property line. The subject site is not located west of the railroad. B.5 Building/Site Identity. In the downtown area, retain a connection with the scale and character of downtown through the use of similar materials, proportions, forms, masses or building elements. Encourage new construction to use designs that reference, but do not replicate historic forms or patterns. Comments: The proposed building is slightly larger in scale than the existing building; however, the proposal incorporates similar colors and materials to provide a linkage between the two buildings without making them match exactly. Although the existing building does not incorporate much modulation or variety in materials, the proposed building uses a variety of forms, colors and materials. The building uses this variety along with modulation to create a feel that reflects the patterns of some of the older buildings in the downtown area. For example, elements of the building are divided into approximate 20- to 30-foot wide lengths which allude to historic development patterns on narrow downtown lots. B.6 Weather Protection. Provide a covered walkway for pedestrians traveling along public sidewalks or walkways. Comments: A canopy is proposed on the southern side of the existing building, which will provide weather protection for pedestrians along Edmonds Street. The proposed building will also have a canopy over a portion of the recessed entry courtyard, which will provide weather protection for individuals entering and exiting the new building. B.7 Signage. Lighting of signs should be indirect or minimally backlit to display lettering and symbols or graphic design instead of broadly lighting the face of the sign. Signage using graphics or symbols or that contributes to the historic character of a building should be encouraged. Comments: No signs were proposed as part of this design review. Signs require separate building permits and are regulated by ECDC 20.60 and are subject to the specific design standards applicable to signs in the BD zones (ECDC 22.43.040). Page 12 of 28 GBH Holdings LLC Phase 2 Design Review File No. PLN20150036 B.8 Art and Public Spaces. Public art and amenities such as mini parks, flower baskets, street furniture, etc., should be provided as a normal part of the public streetscape. Whenever possible, these elements should be continued in the portion of the private streetscape that adjoins the public streetscape. In the 4th Avenue Arts Corridor, art should be a common element of building design, with greater design flexibility provided when art is made a central feature of the design. Comments: The subject site is not located within the Arts Center Corridor. However, the proposal includes steel planters in front of each building along Edmonds Street and hanging flower baskets at the main entries to the new and existing buildings. B.9 Building Height. Create and preserve a human scale for downtown buildings. Building frontages along downtown streetscapes should be pedestrian in scale. Comments: The height of the new building is proposed to be near the limit allowed by the BD2 zone. However, a variety of techniques are employed to reduce the apparent height of the building including the use of a brick base around much of the first floor of the building, the use of decks on the second and third floors, modulating the facades vertically and using a variety of materials and colors. Additionally, the use of a recessed main entry courtyard with a canopy over a portion of the courtyard helps to break up the building form and to identify the main building entry. Although the existing building is generally a box with minimal visual interest, the proposed minor architectural improvements to the existing building, such as the addition of a canopy, planter boxes, and hanging flower baskets on the southern side of the building and the screening of the stairwell on the eastern side of the building will help to provide increased visual interest to the existing building when viewed from the street. B.10 Massing. Large building masses should be subdivided or softened using design elements that emphasize the human scale of the streetscape. Building fagades should respect and echo historic patterns along downtown pedestrian streets. Comments: The proposed building uses a variety of building materials and colors along with vertical modulation to create a feel that reflects the patterns of some of the older buildings in the downtown area. For example, elements of the building are divided into approximate 20- to 30-foot wide lengths which allude to historic development patterns on narrow downtown lots. B.11 Building Facade. Provide a human scale streetscape, breaking up long fagades into defined forms that continue a pattern of individual and distinct tenant spaces in commercial and mixed use areas. Avoid blank, monotonous and imposing building facades using design elements that add detail and emphasize the different levels of the building (e.g. the top or cornice vs. the pedestrian level or building base). Comments: The proposed building employs various techniques to break up the building facades. This includes the use of a brick veneer base around much of the lower floor of the new building, the use of vertical modulation, decks on the second and third floors, and the use of varied siding materials and colors as well as a recessed front entry covered by a canopy. Page 13 of 28 GBH Holdings LLC Phase 2 Design Review File No. PLN20150036 Following the proposed removal of the existing single -story bumpout on the western side of the existing building, this building will not employ any modulation in form or materials, which causes the walls to appear fairly blank. The applicant has proposed a belt course, canopy, planter boxes, and hanging flower baskets along the southern facade of the existing building, which will help to provide visual interest to this side of the building. The remaining facades of the existing building will remain fairly blank in appearance since the majority of the architectural improvements proposed to the existing building are on the southern facade. Staff has included a recommended condition for the applicant to wrap the painted belt course from the southern building fagade around the entire building in order to provide some increased visual interest to the eastern, western, and northern facades and to help reduce the appearance of blank walls. The applicant has also proposed a screening wall to help enhance the look of the exterior stairwell on the eastern side of the existing building. The proposed screening wall, however, is approximately 10 feet tall, which causes this screening wall to become a large blank wall itself. Staff recommends that the screening wall around the stairs be designed at an angle so that it will be triangular -shaped to follow the shape of the stairs. This will provide adequate screening of the stairs without creating a large blank wall. A recommended condition has been added to this effect. B.12 Window Variety and Articulation. In the downtown retail and mixed commercial districts, building storefronts should be dominated by clear, transparent glass windows that allow and encourage pedestrians to walk past and look into the commercial space. Decorative trim and surrounds should be encouraged to add interest and variety. Upper floors of buildings should use windows as part of the overall design to encourage rhythm and accents in the fagade. Comments: The subject site is located on the edge of the commercial core of downtown. No changes are proposed to the existing windows on the existing building. The proposed building will be multi -family residential, so the above criteria are not directly applicable to the proposed project. A variety of window sizes, however, are proposed for the new building in order to provide visual interest to the building. The proposed window sizes and style are consistent with that of typical multi -family development. Based on the above analysis, staff feels that the proposal, as conditioned, is consistent with the above goals and design objectives of the Comprehensive Plan. E. DESIGN GUIDELINE CHECKLIST Pursuant to ECDC 20.12.070.A, the ADB shall use the design guidelines and design review checklist applicable to the district -based design review process when conducting its review. During Phase 1 of the public hearing on September 2, 2015, the ADB established design priorities for the subject application based on the characteristics of the site and the surrounding area. The minutes from that meeting are provided in Exhibit 4, which contain a summary of the checklist priorities established by the ADB. In addition to the Phase 2 project plans (Exhibit 5), the applicant submitted a written statement summarizing how each checklist Page 14 of 28 GBH Holdings LLC Phase 2 Design Review File No. PLN20150036 item was addressed (Exhibit 6). Staff's analysis follows with the ADB's prioritization is in parentheses after each entry: A. Site Planning 1. Reinforce existing site characteristics. (not applicable) 2. Reinforce existing streetscape characteristics. (not applicable) 3. Entry clearly identifiable from the street. (higher priority) Comments: The main entry to the existing building opens directly onto the sidewalk along Edmonds Street. The proposed architectural improvements to the southern side of the existing building (i.e. canopy, planter boxes, and flower baskets) will help to further identify the main entry to the existing building. The entry to the new building will be identified by a recessed entry courtyard, which will be partially covered by a canopy and further identified with the use of flower baskets and lighting. A walkway will connect this entry directly with the sidewalk along Edmonds Street. 4. Encourage human activity on street. (lower priority) Comments: As discussed above, the building entries to the existing and proposed buildings will be clearly identifiable from the street. Steel planter boxes will be provided on the southern sides of both buildings. A low fence will provide some privacy between the patios on the first floor of the new building, while still providing a connection between the site and the adjacent streets, encouraging human activity on the street. 5. Minimize intrusions into privacy on adjacent sites. (lower priority) Comments: The subject site is bordered by private property to the north, 3rd Ave. N to the west, Edmonds St. to the south, and an alley to the east. In an effort to minimize intrusions into privacy on the adjacent property to the north, the project plans include a 6-foot cedar fence along the northern property line. Additionally, landscaping will be utilized to help provide further privacy. 6. Use space between building and sidewalk to provide security, privacy and interaction (residential projects). (not applicable) 7. Maximize open space opportunity on site (residential projects). (lower priority) Comments: A private interior courtyard/walkway area that is approximately 10 feet wide is proposed between the two buildings. Additionally, the recessed entry for the new building will provide for an entry courtyard. Private patios and decks will be provided for each of the new residential units. 8. Minimize parking and auto impacts on pedestrians and adjoining property. (not applicable) 9. Discourage parking in street front. (not applicable) 10. Orient building to corner and parking away from corner on public street fronts (corner lots). (not applicable) B. Bulk and Scale 1. Provide sensitive transitions to nearby, less -intensive zones. (not applicable) Page 15 of 28 GBH Holdings LLC Phase 2 Design Review File No. PLN20150036 C. Architectural Elements and Materials 1. Complement positive existing character and/or respond to nearby historic structures. (lower priority) Comments: There are no structures on the historic register adjacent to the subject site. The existing building was constructed in 1946 according to Snohomish County Assessor records. However, as discussed by the ADB at the Phase 1 hearing, the existing building is very plain and box -like and does not have architectural elements that should be repeated elsewhere on the site. The proposed building ties in with the existing building in terms of building color and some materials (i.e. planter boxes along the southern sides of the buildings, hanging flower baskets at the building entries, and consistent design of fencing/screening walls) while still creating a new identity. The proposed building will utilize brick veneer at the base of the building, which is reminiscent of older buildings in downtown Edmonds, while utilizing more modern design elements throughout the rest of the building. 2. Unified architectural concept. (higher priority) Comments: The proposal includes the use of a consistent color scheme to tie the existing and proposed buildings together. Additionally, both buildings will have matching planter boxes and hanging flower baskets on the southern sides of these buildings. The design of the low fences around the patios on the lower floor of the proposed building will be mimicked with the screening wall around the exterior stairwell on the eastern side of the existing building. 3. Use human scale and human activity. (higher priority) Comments: As mentioned previously, the building uses a number of techniques to create a human scale and encourage human activity. The use of canopies over the building entries, planter boxes, and flower baskets create a human scale at the building entries. The use of brick around much of the lower floor of the proposed building also helps to break up the mass of the proposed building and provide a human scale. The low fences around the patios on the lower floor of the proposed building will help to provide a visual connection between activity on the street and on the subject site. 4. Use durable, attractive and well -detailed finish materials. (higher priority) Comments: The building will be finished with brick, CM4 block, and cementitious siding. The entry canopies will be metal, and cedar horizontal fencing will be utilized throughout the site. This combination of materials will contribute to an attractive appearance. Additional features include residential decks, steel planter boxes, and hanging flower baskets. 5. Minimize garage entrances. (not applicable) D. Pedestrian Environment 1. Provide convenient, attractive and protected pedestrian entry. (higher priority) Comments: The main entry to the existing building opens directly onto the sidewalk along Edmonds Street. The proposed architectural improvements to the southern side of the existing building (i.e. canopy, planter boxes, and flower baskets) will help to further identify Page 16 of 28 GBH Holdings LLC Phase 2 Design Review File No. PLN20150036 the main entry to the existing building. The entry to the new building will be identified by a recessed entry courtyard, which will be partially covered by a canopy and further identified with the use of flower baskets and lighting. A walkway will connect this entry directly with the sidewalk along Edmonds Street. 2. Avoid blank walls. (higher priority) Comments: The proposed building employs various techniques to avoid large blank walls. This includes the use of a brick veneer base around much of the lower floor of the new building, the use of vertical modulation, decks on the second and third floors, and the use of varied siding materials and colors. Following the proposed removal of the existing single -story bumpout on the western side of the existing building, this building will not employ any modulation in form or materials, which causes the walls to appear fairly blank. The applicant has proposed a belt course, canopy, planter boxes, and hanging flower baskets along the southern fagade of the existing building, which will help to provide visual interest to this side of the building. The remaining facades of the existing building will remain fairly blank in appearance since the majority of the architectural improvements proposed to the existing building are on the southern fagade. Staff has included a recommended condition for the applicant to wrap the painted belt course from the southern building fagade around the entire building in order to provide some increased visual interest to the eastern, western, and northern facades and to help reduce the appearance of blank walls. The applicant has also proposed a screening wall to help enhance the look of the exterior stairwell on the eastern side of the existing building. The proposed screening wall, however, is approximately 10 feet tall, which causes this screening wall to become a large blank wall itself. Staff recommends that the screening wall around the stairs be designed at an angle so that it will be triangular -shaped to follow the shape of the stairs. This will provide adequate screening of the stairs without creating a large blank wall. A recommended condition has been added to this effect. 3. Minimize height of retaining walls. (not applicable) 4. Minimize visual and physical intrusion of parking lots on pedestrian areas. (not applicable) 5. Minimize visual impact of parking structures. (not applicable) 6. Screen dumpsters, utility and service areas. (higher priority) Comments: A new trash and recycling enclosure will be provided at the northeastern corner of the site, which will be accessed by tenants from the courtyard/walkway between the two buildings and accessed by haulers from the adjacent alley to the east of the site. Additionally, a heat pump will be located on the northern side of the existing building, which will be screened by the building itself, the trash enclosure, landscaping, and a fence along the northern property line. A transformer is proposed on the east side of the existing building. No specific screening of this transformer is indicated on the plans; however, the transformer will be somewhat screened from view along Edmonds Street by the proposed stair enclosure. Page 17 of 28 GBH Holdings LLC Phase 2 Design Review File No. PLN20150036 7. Consider personal safety. (higher priority) Comments: The building entries will be well lit and will provide direct connections for pedestrians to Edmonds Street. E. Landscaping 1. Reinforce existing landscape character of neighborhood. (lower priority) Comments: Landscaping in the neighborhood is typical of residential and commercial sites, including street trees, shrubs, and groundcover. The applicant's response letter (Exhibit 6) indicates their goal to provide landscaping of a residential character with a seaside emphasis. As indicated on the proposed landscape plan, the landscaping will include a variety of grasses, shrubs, groundcover, and trees. Street trees are required along both Edmonds Street and 3rd Avenue North. 2. Landscape to enhance the building or site. (higher priority) Comments: Since no setbacks are required for the subject site, there are no specific landscaping types required for the street front or buffers. Street trees are required, however. The planting palette offered by the applicant will provide a mix of trees, shrubs, grasses, and groundcover. Steel planter boxes are proposed on the southern sides of the existing and proposed buildings, and hanging flower baskets will also be provided to help define the building entries. 3. Landscape to take advantage of special site conditions. (not applicable) Based on the above analysis, staff feels that the proposal, as conditioned, has adequately addressed the design guidelines checklist as prioritized by the ADB at the Phase 1 hearing. F. APPLICABLE CODES 1. ECDC 16.43 — Downtown Business Zone (BD2) A. ECDC 16.43.020 Uses The site is located in the Downtown Business (Downtown Mixed Commercial), BD2, zone and is subject to the requirements of ECDC 16.43. The proposal is for a new 9-unit residential building and minor architectural improvements to the existing mixed -use building (containing office space on the ground floor and four residential units on the upper floor). Multiple dwelling units are limited in location for properties that have a designated street front as defined in ECDC 16.43.030.B; however, according to Map 16.43-1, the subject site does not have a designated street front (see inset map on the following page). Therefore, the proposed residential use is allowed on the ground floor and is not restricted to being 45 feet back from the right-of-way. Also, the existing office within the ground floor of the mixed -use building is an allowed primary use. Thus, the existing and proposed uses at the subject site are permitted primary uses within the BD2 zone pursuant to ECDC 16.43.020. Page 18 of 28 GBH Holdings LLC Phase 2 Design Review File No. PLN20150036 B. ECDC 16.43.030 Site Development Standards Pursuant to ECDC 16.43.030, development standards in the BD2 zone include: Minimum Height of Minimum Minimum Minimum Minimum Ground Floor Minimum Maximum Zone Lot Area Street Side Rear z within the Lot Width Height (Sq. Ft.) Setback Setback' Setback' Designated Street Fron t4 BD2 None None 0' 0' 0' 30' 12' The setback for buildings and structures located at or above grade (exempting buildings and structures entirely below the surface of the ground) shall be 15 feet from the lot line adjacent to residentially (R) zoned property. Specific provisions regarding building heights are contained in ECDC 16.43.030(C). "Minimum height of ground floor within the designated street front" means the vertical distance from top to top of the successive finished floor surfaces for that portion of the ground floor located within the designated street front (see ECDC 16.43.030(B)); and, if the ground floor is the only floor above street grade, from the top of the floor finish to the top of the ceiling joists or, where there is not a ceiling, to the top of the roof rafters. "Floor finish" is the exposed floor surface, including coverings applied over a finished floor, and includes, but is not limited to, wood, vinyl flooring, wall-to-wall carpet and concrete, as illustrated in Figure 16.43-1. Figure 16.43-1 shows an example of a ground floor height of 15 feet; note that the 'finished" ceiling height is only approximately 11 feet in this example. Height: The maximum allowed height in the BD2 zone is 30 feet above average original grade. Certain height exceptions provided for in ECDC 16.43.030.C.3. As indicated on the Phase 2 project plans (Exhibit 5), the proposed building will be constructed within a few inches of the 30-foot height limit. It appears that the proposed building will comply with the applicable height requirements. Height compliance will be confirmed during building permit review and then verified in the field by survey since the building will be very near the height limit. Minimum Height of Ground Floor: Pursuant 0 to ECDC 16.43.030.13, a designated street front is applicable as shown on Map 16.43-1. As can be seen in the excerpt of Map 16.43-1 inset to the right, the subject site does not have a designated street front. Therefore, none of the use restrictions nor the minimum height of ground floor r requirements applicable Page 19 of 28 GBH Holdings LLC Phase 2 Design Review File No. PLN20150036 to BD -zoned properties with a designated street front apply to the subject site. Thus, there is no minimum height of ground floor requirement for the proposed project. Setbacks: Since the subject site is not directly adjacent to residentially (R) zoned property, no setbacks are required for the proposed building. Any existing or proposed features that project into the City right-of-way may require an encroachment permit and/or street use permit, which will be verified by the Engineering Division during their review of the associated building permit application. Open Space: Pursuant to ECDC 16.43.030.E, open space is required for buildings on lots larger than 12,000 square feet or having an overall building width of more than 120 feet. The subject site is approximately 7,050 square feet, and both buildings are well under 120 feet in width. As such, the proposal is not large enough to trigger the requirement to provide open space. The proposal, as conditioned, does not appear to conflict with the applicable zoning standards of ECDC 16.43. As always, the project will be reviewed for compliance with all applicable development standards during the building permit review process. 2. ECDC 17.50 Off Street Parkine Reeulations Although the City's off-street parking regulations are chiefly contained in ECDC 17.50, parking within the Downtown Business (BD) zones is regulated in ECDC 16.43. Pursuant to ECDC 16.43.030.D, no parking is required for any commercial floor area of permitted uses located within the BD2 zone and no parking is required for any floor area in any building with a total building footprint of less than 4,800 square feet. As indicated on the Phase 2 project plans (Exhibit 5), both the existing building and the proposed building have footprints of well under 4,800 square feet. Thus, no on -site parking is required for the subject site. As indicated on the project plans, no on -site parking is proposed. 3. ECDC 20.15A Environmental Review (SEPA) Review under the State Environmental Policy Act (SEPA) was required for this project because the proposed project exceeds four new residential units. A SEPA Determination of Nonsignificance was issued on October 20, 2015 (Exhibit 7). No appeals have been received to date. 4. ECDC 22.43 Design Standards for the BD Zones Design standards applicable to the BD zones are provided in ECDC Chapter 22.43. Refer to Exhibit 5 for Phase 2 elevation drawings and renderings. A. ECDC 22.43.010 Massing and Articulation. Intent— To reduce the massiveness and bulk of large box -like buildings, and articulate the building form to a pedestrian scale. Buildings shall convey a visually distinct base and top. A "base" can be emphasized by a different masonry pattern, more architectural detail, visible plinth above which the wall rises, storefront, canopies, or a combination. The top edge is highlighted by a prominent cornice, projecting parapet or other architectural element that creates a shadow line. Page 20 of 28 GBH Holdings LLC Phase 2 Design Review File No. PLN20150036 Comments: The brick veneer around much of the lower floor of the proposed building gives the new building a visually distinct base and top. The base is further distinguished with the use of various human -scale design elements such as a canopy over a portion of the main entry courtyard, flower baskets at the main entry, steel planter boxes, and low fences around the patios. The entire building is modulated vertically, and the upper two floors include multiple decks. The existing building does not have a visually distinct base and top. The majority of the architectural improvements proposed to the existing building are on the southern fagade, which leaves the eastern, western, and northern facades of the building still fairly blank in appearance. Staff has included a recommended condition of approval for the painted belt course on the southern building fagade to be wrapped around all four sides of the existing building in order to provide some increased visual interest to the eastern, western, and northern facades. This will also help to provide the existing building with a somewhat more distinct base and top. 2. Building facades shall respect and echo historic patterns. Where a single building exceeds the historic building width pattern, use a change in design features (such as a combination of materials, windows or decorative details) to suggest the traditional building widths. Comments: Existing building widths in the downtown area generally vary from about 30 to 60 feet. The proposed building is roughly 60 feet wide along Edmonds Street and less than 60 feet wide along 3rd Ave. N. Through the use of vertical modulation and varied materials, the apparent width of the building is reduced on both facades. B. ECDC 22.43.020 Orientation to Street. Intent — To reinforce pedestrian activity and orientation and enhance the liveliness of the street through building design. 1. Building frontages shall be primarily oriented to the adjacent street, rather than to a parking lot or alley. Comments: The existing building fronts directly onto Edmonds Street. Although the proposed building will be adjacent to both 3rd Avenue North and Edmonds Street, the proposed building will only be accessed from Edmonds Street. The entry to this building will be located within a recessed courtyard that provides a direct pedestrian connection via a walkway to the sidewalk along Edmonds Street. 2. Entrances to buildings in the BD1, BD2 and BD4 zones shall be visible from the street and accessible from the adjacent sidewalk. Comments: The main entrance to the existing building is directly accessible and at grade with the sidewalk along Edmonds Street. The proposed improvements to the existing building will help to draw further attention to this building entry. The second floor of the existing building is accessed via the stairwell along the eastern side of the existing building, which connects directly to the sidewalk along Edmonds Street. The appearance of this stairwell will be improved with a new screening wall. Page 21 of 28 GBH Holdings LLC Phase 2 Design Review File No. PLN20150036 The entry to the proposed building will also be visible from the street and will be directly accessible via a walkway connecting it to the sidewalk along Edmonds Street. The entry to the proposed building will be from a recessed courtyard, which will help to distinguish this entry and provide visual interest and modulation to the building. 3. Entrances shall be given a visually distinct architectural expression by one or more of the following elements: a. Higher bay(s), b. Recessed entry (recessed at least three feet), c. Forecourt and entrance plaza. Comments: Although the existing building does not employ one of the above design elements, the addition of a canopy over the main entry and the use of steel planters and hanging flower baskets will help to identify the main entry and to provide increased visual interest. The appearance of the stairwell accessing the second floor of the existing building will be enhanced with a new screening wall. Refer to the discussion above regarding staff's recommended condition of approval to modify the shape of the screening wall so that it follows the shape of the stairwell. The main entry to the proposed building will be given a visually distinct architectural expression with the use of a recessed entry, which will be recessed enough to create a small entry courtyard. C. ECDC 22.43.030 Ground Level Details. Intent — To reinforce the character of the streetscape by encouraging the greatest amount of visual interest along the ground level of buildings facing pedestrian streets. 1. Ground floor, street facing facades of commercial and mixed -use buildings shall incorporate at least five of the following elements: a. Lighting or hanging baskets supported by ornamental brackets, b. Medallions, c. Belt courses, d. Plinths for columns, e. Bulkhead for storefront window, f. Projecting sills, g. Tile work, h. Transom or clerestory windows, i. Planter box, j. An element not listed here, as approved, that meets the intent. Comments: The minor architectural improvements proposed to the existing building will include the following ground level details: lighting, hanging baskets, planter boxes, a beltcourse, and a canopy. The proposed building is not a commercial nor a mixed -use building, so these specific standards do not apply to the new building. The proposed building, however, will include several ground level details such as lighting, hanging baskets at the main building entry, planter boxes, a canopy over a portion of the main entry courtyard, and brick veneer around much of the lower floor. Page 22 of 28 GBH Holdings LLC Phase 2 Design Review File No. PLN20150036 2. Ground floor commercial space is intended to be accessible and at grade with the sidewalk, as provided for in ECDC 16.43.030. Comments: The commercial space on the ground floor of the existing building is directly accessible and at grade with the sidewalk along Edmonds Street. No commercial space is proposed within the new building. D. ECDC 22.43.040 Awnings/Canopies and Signage. Intent —1) To integrate signage and weather protection with building design to enhance business visibility and the public streetscape. 2) To provide clear signage to identify each business or property, and to improve way finding for visitors. 3) To protect the streetscape from becoming cluttered, and to minimize distraction from overuse of advertisement elements. 1. Structural canopies are encouraged along pedestrian street fronts. If a canopy is not provided, then an awning shall be provided which is attached to the building using a metal or other framework. Comments: The proposal includes a canopy over a portion of the main entry courtyard to the proposed building and a metal canopy on the southern side of the existing building over the main entry. No awnings are proposed. 2. Awnings and canopies shall be open -sided to enhance visibility of business signage. Front valances are permitted. Signage is allowed on valances, but not on valance returns. Comments: All canopies are open -sided, no awnings are proposed. 3. Marquee, box, or convex awning or canopy shapes are not permitted. Comments: The proposed canopies are flat. 4. Retractable awnings are encouraged. Comments: No retractable awnings are proposed. 5. Awnings or canopies shall be located within the building elements that frame store- fronts, and should not conceal important architectural details. Awnings or canopies should be hung just below a clerestory or transom window, if it exists. Comments: The proposed canopy on the southern side of the existing building will help to provide visual interest to an otherwise fairly blank fagade. This canopy will also help to draw attention to the main entrance to the existing building. This building does not have clerestory or transom windows. The proposed building will have a canopy over a portion of the main entry courtyard. This building also will not have clerestory or transom windows, but the canopy will help to define the main building entry and to provide weather protection for individuals entering and exiting the building. Neither of the proposed canopies will conceal any architectural features. 6. Awnings or canopies on a multiple -storefront building should be consistent in character, scale and position, but need not be identical. Page 23 of 28 GBH Holdings LLC Phase 2 Design Review File No. PLN20150036 Comments: Neither the existing nor the proposed building have multiple storefronts. 7. Nonstructural awnings should be constructed using canvas or fire-resistant acrylic materials. Shiny, high -gloss materials are not appropriate; therefore, vinyl or plastic awning materials are not permitted. Comments: No awnings are proposed. 8. Signage should be designed to integrate with the building and street front. Com- binations of sign types are encouraged, which result in a coordinated design while minimizing the size of individual signs. Comments: No signage was included with this proposal. Signage will be reviewed for compliance with the applicable design standards of ECDC 22.43.040 and the sign code requirements of ECDC 20.60 when a sign application is submitted. 9. Blade or projecting signs which include decorative frames, brackets or other design elements are preferred. Projecting signs (including blade signs) of four square feet or less are permitted and are not counted when calculating the amount of signage permitted for a business in ECDC 20.60. This type of detail can be used to satisfy one of the required elements under ECDC 22.43.030(B). Comments: No signage was included with this proposal. Signage will be reviewed for compliance with the applicable design standards of ECDC 22.43.040 and the sign code requirements of ECDC 20.60 when a sign application is submitted. 10. Use graphics or symbols to reduce the need to have large expanses of lettering. Comments: No signage was included with this proposal. Signage will be reviewed for compliance with the applicable design standards of ECDC 22.43.040 and the sign code requirements of ECDC 20.60 when a sign application is submitted. 11. Instead of broadly lighting the face of the sign, signage should be indirectly lit, or backlit to only display lettering and symbols or graphic design. Comments: No signage was included with this proposal. Signage will be reviewed for compliance with the applicable design standards of ECDC 22.43.040 and the sign code requirements of ECDC 20.60 when a sign application is submitted. 12. Signage should be given special consideration when it is consistent with or con- tributes to the historic character of sites on the National Register, the Edmonds Register of Historic Places, or on a city council -approved historic survey. Comments: Not applicable. The subject site is not on the National Register, the Edmonds Register of Historic Places, nor on a city council -approved historic survey. 13. Signage shall include decorative frames, brackets or other design elements. An historic sign may be used to meet this standard. Comments: No signage was included with this proposal. Signage will be reviewed for compliance with the applicable design standards of ECDC 22.43.040 and the sign code requirements of ECDC 20.60 when a sign application is submitted. Page 24 of 28 GBH Holdings LLC Phase 2 Design Review File No. PLN20150036 E. ECDC 22.43.050 Transparency at Street Level. Intent — To provide visual connection between activities inside and outside the building. 1. The ground level facades of buildings that face a designated street front shall have transparent windows covering a minimum of 75 percent of the building facade that lies between an average of two feet and 10 feet above grade. Comments: Not applicable. The subject site does not have a designated street front. 2. To qualify as transparent, windows shall not be mirrored or darkly tinted glass, or prohibit visibility between the street and interior. Comments: Not applicable. The subject site does not have a designated street front. 3. Where transparency is not required, the facade shall comply with the standards under ECDC 22.43.060. Comments: Compliance with the standards of ECDC 22.43.060 is discussed below. 4. Within the BD1 zone, ground floor windows parallel to street lot lines shall be transparent and unobstructed by curtains, blinds, or other window coverings intended to obscure the interior from public view from the sidewalk. Comments: Not applicable since the site is not located within the BD1 zone. F. ECDC 22.43.060 Treating Blank Walls. Intent — To ensure that buildings do not display blank, unattractive walls to the abutting street. 1. Walls or portions of walls on abutting streets or visible from residential areas where windows are not provided shall have architectural treatment (see standards under ECDC 22.43.050). At least five of the following elements shall be incorporated into any ground floor, street facing facade: a. Masonry (except for flat, nondecorative concrete block), b. Concrete or masonry plinth at the base of the wall, c. Belt courses of a different texture and color, d. Projecting cornice, e. Decorative tile work, f. Medallions, g. Opaque or translucent glass, h. Artwork or wall graphics, i. Lighting fixtures, j. Green walls, k. An architectural element not listed above, as approved, that meets the intent. Comments: There are no large expanses of blank walls on either building where windows are not provided. Following the proposed removal of the existing single -story bumpout on the western side of the existing building, however, this building will have no modulation and will appear as a box with little visual interest. The applicant has proposed a belt course, canopy, planter boxes, and hanging flower baskets along the Page 25 of 28 GBH Holdings LLC Phase 2 Design Review File No. PLN20150036 southern facade of the existing building, which will help to provide visual interest to this side of the building. The remaining facades of the existing building will remain fairly blank in appearance since the majority of the architectural improvements proposed to the existing building are on the southern fagade. Staff has included a recommended condition for the applicant to wrap the painted belt course from the southern building fagade around the entire building in order to provide some increased visual interest to the eastern, western, and northern facades. Additionally, the applicant has proposed a screening wall to help enhance the look of the exterior stairwell on the eastern side of the existing building. The proposed screening wall, however, is approximately 10 feet tall, which causes this screening wall to become a large blank wall itself. Staff recommends that the screening wall around the stairs be designed at an angle so that it will be triangular -shaped to follow the shape of the stairs. This will provide adequate screening of the stairs without creating a large blank wall. A recommended condition has been added to this effect. G. ECDC 22.43.070 Building HVAC Equipment. Intent — To ensure that HVAC equipment, elevators, and other building utility features are designed to be a part of the overall building design and do not detract from the streetscape. Rooftop HVAC equipment, elevators and other rooftop features shall be designed to fit in with the materials and colors of the overall building design. These features shall be located away from the building edges to avoid their being seen from the street below. If these features can be seen from the adjoining street, building design shall use screening, decoration, plantings (e.g., rooftop gardens), or other techniques to integrate these features with the design of the building. Comments: Because the building is proposed to be built nearly to the 30' height limit, it is not likely that rooftop HVAC equipment will be possible within the height limit. An elevator is not included in the proposed building. 2. When HVAC equipment is placed at ground level, it shall be integrated into building design and/or use screening techniques to avoid both visual and noise impacts on adjoining properties. Comments: A heat pump will be located on the northern side of the existing building, which will be screened by the building itself, the trash enclosure, landscaping, and a fence along the northern property line. A transformer is proposed on the east side of the existing building. No specific screening of this transformer is indicated on the plans; however, the transformer will be somewhat screened from view along Edmonds Street by the proposed stair enclosure. Based on the above analysis, staff feels that the proposal, as conditioned, is consistent with design standards contained within ECDC Chapter 22.43. 5. ECDC 20.13 Landscaping Requirements ECDC 20.13 contains specific landscaping requirements for new development. In this case, because there are no required setbacks for the project, there are no specific landscape types in ECDC 20.13.030 that must be used. The remainder of the requirements in ECDC Page 26 of 28 GBH Holdings LLC Phase 2 Design Review File No. PLN20150036 20.13 do apply, however. Pursuant to ECDC 20.13.000, the ADB may interpret and modify the landscaping requirements of ECDC 20.13 provided such modification is consistent with the purposes found in ECDC 20.10.000. As indicated on the landscape plan within Exhibit 5, the applicant has proposed a mix of trees, shrubs, grasses, and groundcover. Since the majority of the site will be taken up with the existing and proposed buildings, there is not a lot of room on site for additional trees, but street trees will be provided along both Edmonds Street and 3rd Avenue North, and a couple of smaller decorative trees will also be provided on the site. The proposed landscaping will help to provide visual interest to the building entries and help to provide some privacy for the first floor units within the new building. In addition to the landscaping located on the site, street trees are also required. The City's Street Tree Plan includes recommendations for size, species, planting procedures, etc. According to the Plan, Capital Pear is the recommended tree for 3rd Ave. N and Bowhall Maple is called out for Edmonds Street. As indicated in the Engineering Division's memorandum dated October 23, 2015 (Exhibit 10), spacing of the street trees along Edmonds Street is required to be at 30 feet on center. The applicant has shown Musashino Zelkova along 3rd Ave. N and Capital Pear along Edmonds Street; the exact selection of tree species as well as size, spacing, and the like will be addressed at building permit application review. Planter baskets are also proposed on the southern sides of the existing and proposed buildings and hanging flower baskets are proposed at the main entries to both buildings. This will help to provide visual interest at the building entries as well as provide further identification of the locations of these entries. As conditioned, staff feels that the proposed landscaping is consistent with the requirements of the Street Tree Plan and ECDC 20.13. 6. ECDC 20.60 Signs No signs were proposed as part of this design review. Signs require separate building permits and are regulated by ECDC 20.60 and are subject to the specific design standards applicable to signs in the BD zones (ECDC 22.43.040). III. RECOMMENDATION Pursuant to ECDC 20.12.020, when approving proposed development applications, the ADB is required to find that the proposed development is consistent with the zoning ordinance, the design objectives of the Comprehensive Plan, and the specific design criteria identified by the ADB during Phase 1 of the public hearing. Based on the findings, analysis, conclusions, and exhibits of this report, staff recommends that the Architectural Design Board APPROVE the proposal under File No. PLN20150036 with conditions as stated in the following recommended motion: THE ARCHITECTURAL DESIGN BOARD ADOPTS THE FINDINGS, CONCLUSIONS AND ANALYSIS OF THE STAFF REPORT AND FINDS THAT THE PROPOSAL IS CONSISTENT WITH THE ZONING ORDINANCE, THE DESIGN OBJECTIVES OF THE COMPREHENSIVE PLAN, THE DESIGN CRITERIA Page 27 of 28 68H Holdings LLC Phase 2 Design Review File No. PLN20150036 IDENTIFIED DURING PHASE 1 OF THE PUBLIC HEARING, AND THE DESIGN STANDARDS OF ECDC 22.43, AND APPROVES THE PROPOSAL WITH THE FOLLOWING CONDITIONS: 1. ADDITIONAL INTEREST SHALL BE ADDED TO THE EXISTING BUILDING BY EXTENDING THE PAINTED BELTCOURSE FROM THE SOUTEHRN FACADE AROUND ALL FOUR BUILDING FACADES. 2. THE SCREENING WALL AROUND THE EXTERIOR STAIRWELL SHALL BE ANGLED TO FOLLOW THE SLOPE OF THE STAIRS. 3. THE SCREENING OF THE STAIRWAY ON THE EAST SIDE OF THE EXISTING BUILDING SHALL NOT EXTEND FURTHER SOUTH THAN THE FACE OF THE BUILDING TO PREVENT OBSCURING PEDESTRIANS FROM CARS EXITING THE ALLEY. 4. THREE STREET TREES SHALL BE PROVIDED ALONG EDMONDS STREET AT 30' ON CENTER SPACING PER THE CITY OF EDMONDS STREET TREE PLAN. STREET TREE SIZING AND SPECIES IS TO BE DETERMINED AT THE TIME OF BUILDING PERMIT REVIEW. 5. THE APPLICANT MUST APPLY FOR AND OBTAIN ALL NECESSARY PERMITS. THIS APPLICATION IS SUBJECT TO THE REQUIREMENTS IN THE EDMONDS COMMUNITY DEVELOPMENT CODE. IT IS UP TO THE APPLICANT TO ENSURE COMPLIANCE WITH THE VARIOUS PROVISIONS CONTAINED IN THESE ORDINANCES. IV. PARTIES OF RECORD City of Edmonds 121— 5th Ave North Edmonds, WA 98020 Glenn Safadago GBH Holdings, LLC P.O. Box 1509 Langley, WA 98260 V. INTERESTED PARTIES Ed Chu 125 2nd Ave. N Edmonds, WA 98020 Steve Butterfield TBG Architects 21911 76th Ave. W, Suite 210 Edmonds, WA 98026 Barbara and Patrick Marker 233 4th Ave. N Edmonds, WA 98020 Heidi Fyall 742 Melody Ln. Edmonds, WA 98020 Page 28 of 28