Loading...
pln20150050-Bracketts Corner-ADB-E2.pdfDate: To: From: Subject: MEMORANDUM December 21, 2015 Sean Conrad, Associate Planner Jeanie McConnell, Engineering Program Manager PLN20150050 — Design Review Brackett's Corner — 8000 — 212'h St SW The comments provided below are based upon review of the application and documents submitted for design review for Brackett's Corner at 8000 — 212' St SW. Additional information is requested from the applicant at this time. Please ask the applicant to respond to the following. 1. Completed 2. Completed 3. 12121115 Please revise and resubmit geotech report and plans per the comments below. The June 15, 2015 geotech report prepared by Liu & Associates includes a Site and Exploration Location Plan that identifies test pit locations. One of the test pit locations aligns with a proposed infiltration gallery, but the other two do not. Please conduct additional soils testing in the location of the proposed infiltration galleries to confirm that the proposal is feasible. • The geotech used a method from the 2012 Ecology manual that we do not currently recognize for assessment of infiltration rates. Methods in the 2005 Ecology manual must be used. Since this site will be over an acre, the pilot infiltration test (PIT) described in the 2005 manual should be used. Tests must be conducted at the locations of the proposed infiltration BMPs. • Since the site is over an acre, LID BMPs cannot be designed using the E72B handout. They must be modeled and designed by an Engineer. • Due to the density of the development, stormwater BMPs may need to be located under the driveways. • A full stormwater report describing how the site meets all the applicable minimum requirements will be required. Thank you. City of Edmonds