Loading...
PLN20160006 Complete Application Letter.pdfCITY OF EDMONDS 121 5th Avenue North, Edmonds WA 98020 Phone: 425.771.0220 • Fax: 425.771.0221 • Web: www.edmondswa.gov DEVELOPMENT SERVICES DEPARTMENT • PLANNING DIVISION Inn. 189" June 13, 2016 Gus and Morgan Kays Via email: gkays@herrerainc.com SUBJECT: COMPLETE APPLICATION LETTER FOR SHORT PLAT APPLICATION LOCATED AT 8705 MAPLEWOOD LANE, FILE NO. PLN20160006 Dear Mr. and Mrs. Kays: Your land use application for a three lot subdivision located at8705 Maplewood Lane (File No. PLN20160006) is considered complete pursuant to Edmonds Community Development Code (ECDC) 20.02.002. Within the next two weeks I will be notifying your neighbors and the general public, through postings and legal notice in the paper, of your request to subdivide your property. The public and your neighbors will be afforded a two week comment period. Once the comment period is completed, I will continue my review of your application. Please note, however, that although it has been determined that the application meets the procedural submission requirements and is therefore complete, additional information is still needed for city staff to continue with review of the application. Please see the attached memo from the Engineering Division dated June 8, 2016. This information and any other information requests from city staff will need to be submitted prior to staff completing its review of your subdivision application. I will be the main staff contact for your application. If you have questions at any point during the review process, you may reach me at (425) 771-0220 or sean.conrad@edmondswa.gov. Sincerely, Development Servi es Department - Planning Division -:S� Sean Conrad Associate Planner Cc: File No. PLN20160006 Attachment Date: To: From: Subject: MEMORANDUM June 8, 2016 Sean Conrad, Associate Planner JoAnne Zulauf, Engineering Technician PLN20160006, Kays 3 lot short plat 8705 Maplewood The comments provided below are based upon review of the preliminary civil plans & documents for the subject short plat. Additional information is requested from the applicant at this time in order to continue review of the application and provide preliminary approval of the short plat. Please ask the applicant to provide a written response to each of the outstanding comments below and revise and resubmit plans accordingly. Please also note, after receiving preliminary short plat approval from the Planning Division, the applicant will be required to submit civil engineering plans to the City for review and approval after receiving preliminary short plat approval from the Planning Division. 1. 6/8/16 completed. 2. 6/8/16 Full infiltration testing report received. 6/8/15 Not done. 1. Site categorization is incorrectly noted as a Small Site Category 1. A project is defined in ECDC 18.30 (and the 2005 Stormwater Manual) as "that portion of a property, properties, or right-of-way subject to land -disturbing activities, new impervious surfaces, or replaced impervious surfaces. If the project is part of a common development plan or sale the disturbed area of the entire plan shall be used in determining permit requirements." Therefore the impervious surface for the project would include both lots and the area of the road widening. This project exceeds 5,000 sf of disturbed area and new impervious so the project would correctly be categorized as a Small Site Category 2. All mitigation systems for this project must be sized under Category 2 requirements. 2. The impervious surface of the additional roadway mitigation was not addressed in this submittal. There are two options to mitigating this runoff. a. Add a mitigation system at the lowest elevation and use berms or some other method to direct the runoff. b. Probably the least difficult option, collect runoff from an equal amount of impervious surface on the existing lot to provide essentially a swap the collection area. City of Edmonds Dispersion techniques may be an option to explore, 2005 DOE Manual Chapter V section 5.3. 3. Please add the road widening impervious surface amount under "Proposed Plat Surfaces" Original Comment: Determine site categorization per the Engineering Handout E72, then design rain gardens for the estimated impervious surface for each lot. A scaled rain garden or other stormwater bmp must be shown on the plans to determine if location and sizing are feasible. 4. 6/8/16 Completed. Thank you.