PLN20170004-Rose-ADU-E1.pdfDate:
To:
From:
Subject:
MEMORANDUM
March 13, 2017
Jen Machuga, Associate Planner
Jeanie McConnell, Engineering Program Manager
PLN20170004 — Conditional Use - ADU
Rose — 7219 Lake Ballinger Way
The comments provided below are based upon review of the application and documents
submitted for an accessory dwelling unit at 7219 Lake Ballinger Way. Additional
information is requested from the applicant at this time. Please ask the applicant to respond to
the following.
PARKING
The application states a total of 5 parking spaces will be provided on the site. The site plan
submitted indicates a total of 4 parking stalls will be provided. Please respond to the
following with regards to parking:
1. Dimension parking areas to confirm minimum parking stall dimensions can be met —
8 1/z ft in width by 16 1/z feet in length.
2. Where parking is provided, an on -site turnaround must be present. Vehicles will not
be permitted to back out onto Lake Ballinger Way.
3. Clearly show pavement areas on the site plan (both existing and proposed).
STORMWATER
Stormwater management will be required consistent with Edmonds Community Development
Code Chapter 18.30 and the 2014 DOE Stormwater Manual. In general, if the proposed
project creates over 2000 square feet of impervious surface area, stormwater management will
need to be addressed. This would occur at the building permit phase of the project, but the
plans for the ADU should clearly identify existing and proposed impervious surface areas.
Thank you.
City of Edmonds