PRE2011-0016 SFR 92xx OVD.doc
MEMORANDUM
June 30, 2011
Date:
Mr Bruce Lambrecht
To:
Fire Marshal John J. Westfall 425.771.0213
From:
Subject: PRE2011-0016 Single Family Residence 92xx OVD
This Review is conducted in accordance with 2009 IFC and Edmonds Community Development
Code. Fire Services provides the following comments:
1. Approved fire access is 400’ from approved access roadway on Olympic View Drive.
Install turnaround for private road in accordance with COE Engineering Standards. (E2.5
attached). Turnaround may incorporate private road and is not required entirely on site.
2. Existing hydrant meet proper spacing requirements ECDC 19.25.055 C.
3. For information, flow-through design residential fire sprinkler systems are required when
dwelling living space exceeds 3,000 s.f. ECDC 19.05.020 C.
4. For information, provide minimum combination water-service of one inch (1”) meter and
one and one quarter inch (1 ½ ”) service line for each property; or show that domestic
and fire protection needs, when required, can be met with smaller service. General
Facility Charges are based upon domestic requirements only. For instance, up-sizing to
one inch (1”) meter will be calculated to fees for a three quarter inch (3/4”) connection.
Equipment will be charged by actual equipment costs.
5. Obtain building address from Development Services for house addressed from access
frontage. Post approved address on building minimum 6” letters on contrasting
background viewable from private drive.
City of Edmonds Office of Fire Marshal