Loading...
Preliminary Staff Report.pdfI/)c. I S9> -, CITY OF EDMONDS 121 51h Avenue North, Edmonds WA 98020 Phone: 425.771.0220 • Fax: 425.771.0221 • Web: www.edmondswa.gov DEVELOPMENT SERVICES DEPARTMENT • PLANNING DIVISION PLANNING DIVISION PRELIMINARY SHORT PLAT REVIEW FINDINGS, CONCLUSIONS, & DECISION Project: Select Homes 3-Lot Short Subdivision File Number: PLN20170046 Date of Report: January 5, 2018 Reviewed By: Michele Q. Szafran, Plattner Owner: Select Homes, Inc. Applicant: Same as Owner Applicant's Agent: Kayla Clark I. INTRODUCTION The applicant is proposing to subdivide a 38,947 square foot parcel addressed 18807 188"' St. SW into three lots (Attachments 1- 3). The site is located within the Single -Family Residential (RS- 10) zone that allows lots with a minimum net area of 10,000 square feet. See the Zoning and Vicinity Map for reference (Attachment 4). The proposed lot layout is shown on the preliminary short plat plans (Attachment 2) and preliminary development plans (Attachment 3). The existing single-family residence and associated improvements are to be removed. Lots 2 and 3 are proposed to take individual access directly from 188"' St. SW, and Lot 1 is proposed to take access off of 88"' Ave. W. A. Application 1. Owner: Select Homes, Inc. 2. Applicant: Same as Owner 3. Applicant's Agent: Kayla Clark 4. Site Location: 18807 188"' St. SW, Edmonds, WA (Tax Parcel 00434600001701) 5. Re uest: To divide one lot with a total area of 38,947 square feet into three lots in a Single -Family Residential (RS-10) zone. The lots are proposed to be developed with single-family residences. 6. Review Process: Short plats are Type II decisions pursuant to ECDC 20.01.003. Following a public comment period, the Director (or designee) makes an administrative decision. Note: All code sections referenced in this report can be viewed via the City's website, located at www.edmondswa.aov. B. Application Materials: The subject application was submitted on September 26, 2017 (Attachment 1) and included preliminary short plat and development plans which were since revised (Attachments 2 and 3), storm drainage report which was since revised (Attachment 5), Edmonds Utilities Consortium form and correspondence from Puget Sound Energy (Attachment 6), title report, and adjacent property owner's list (Attachment 8). The application was found to be complete pursuant to ECDC 20.02.002 on October 24, 2017 (Attachment 7), and a letter requesting additional information was sent to the applicant on November 9, 2017 (Attachment 9). On December 14, 2017, the applicant submitted a cover letter (Attachment 10), and a revised preliminary short plat and development plans (Attachments 2 and 3 respectively). II. FINDINGS OF FACT AND CONCLUSIONS A. Setting: The subject site is located within a single-family residential neighborhood. Refer to Attachment 4 for a zoning and vicinity map indicating the zoning of surrounding properties. The subject property is zoned Single -Family Residential, RS-10. Adjacent properties are also located within the RS-10 zone and RS-12 zone and are developed with single-family residences. B. Topography and Vegetation: Refer to the preliminary short plat and development plans (Attachments 2 and 3) for a depiction of the existing conditions on the site, including the topography of the site and locations of existing trees. Vegetation throughout the central portion of the site is that of typical residential landscaping, including grass, shrubs, and trees while the eastern portion of the site is in a more natural state with several trees and unmaintained understory. C. Environmental Assessment 1. Critical Area: The subject property was reviewed and inspected for critical areas as defined by ECDC 23.40 in 2017 under File No. CRA20170164, and it was determined that there are no critical areas on or adjacent to the subject property and a waiver was issued. 2. Shoreline: The subject property is not located within shoreline jurisdiction. 3. SEPA: Review under the State Environmental Policy Act (SEPA) is not required for a short plat pursuant to WAC 197-11-800(6)(d) - Land use decisions. Select Homes Short Plat File No. PLN20170046 Page 2 of 13 D. Comments 1. Departmental Comment: This proposal was reviewed by Snohomish County Fire District No. 1, by the Building Division, and by the Public Works Department — Engineering Division. Snohomish County Fire District No. 1 and the Building Division did not have any comments on the proposed short plat (Attachments 11 and 13) The Engineering Division did have preliminary comments on the proposal (Attachment 12). Following review of the revised plans (Attachments 2 and 3), the Engineering Division approved the proposed subdivision subject to the approval memorandum and Engineering Requirements for the short plat that are included in Attachment 16. The Engineering Division has found the information provided indicates general engineering feasibility; project -specific design, including final utility system design and location, as well as Title 18 Edmonds Community Development Code compliance, will be reviewed during the civil construction phase of this project. The proposed subdivision is subject to the Engineering Requirements for the short plat included in Attachment 16. 2. Public Notice and Comment: ECDC Chapter 20.03 provides the City's regulations for public notice of development applications. A "Notice of Application" dated November 7, 2017 with a comment period running through November 22, 2017 was posted at the subject site, Public Safety Complex, Development Services Department, and Library on November 7, 2017. The notice was also published in the Herald Newspaper and mailed to property owners within 300 feet of the site on November 7, 2017 using a mailing list provided by the applicant. Documentation of compliance with the public notice requirements is included as Attachment 8. The City has complied with the public notice requirements of ECDC 20.03. One public comment was received during review of the subject proposal. Anjum Hajat sent an email on December 6, 2017 (Attachment 14) addressing concerns related to the safe passage to and from the nearby Elementary School as well as concerns of air pollution put off by construction vehicles and equipment especially to children walking to and from school. Slab Response: Staff forwarded the December 6, 2017 email comment from Anjum Hajat to the applicant on December 11, 2017. The applicant responded via email on December 15, 2017 (Attachment 15) stating in part that most work will be taking place over the summer months, but outside of that the superintendent on the project will be informed to allow for safe passage for school children. The applicant also responded regarding air pollution stating in part that some of the equipment used are electric and that gas/diesel equipment is well maintained so that air pollutants generally are no more of an issue than what general traffic would emit. Staff also forwarded the December 6, 2017 email comment from Anjum Hajat to the engineering department on January 2, 2018. Staff responded in the engineering memo of compliance on January 2, 2018 (Attachment 16). Staff stated in part that during the next phase of the subdivision process the developer will be required to provide a traffic/pedestrian plan that will be reviewed by the City's Transportation Engineer. Staff also noted that the city does not have any regulatory power over when machinery is on or off during regular construction hours. Select Homes Short Plat File No. PLN20170046 Page 3 of 13 E. ECDC 20.75.080 General Findings A proposed subdivision may only be approved if all the general findings listed in ECDC 20.75.080 can be made for the proposal as approved or as conditionally approved. Staff s findings in regard to ECDC 20.75.080 are detailed below. 1. Subdivision Ordinance. The proposal is consistent the purposes of this chapter (as listed in ECDC 20.75.020) and meets all requirements of this chapter. As conditioned, the proposed three lot subdivision is consistent with ECDC 20.75.020 and all the requirements of ECDC Chapter 20.75. The proposed subdivision will not negatively impact public health, safety or general welfare, will not negatively impact congestion on streets and highways, will have adequate access to water, utilities, sewerage, storm drainage and will provide proper ingress and egress as well as be uniformly monumented. 2. Comprehensive Plan. The proposal is consistent with the provisions of the Edmonds Comprehensive Plan, or other adopted city policy, and is in the public interest. The subject site is located within the "Single Family — Urban 3" designation of the Comprehensive Plan. The Comprehensive Plan has the following stated goals and policies for Residential Development that apply to this project. Residential Development A. Goal. High quality residential development which is appropriate to the diverse lifestyle of Edmonds residents should be maintained and promoted. The options available to the City to influence the quality of housing for all citizens should be approached realistically in balancing economic, social, aesthetic and environmental considerations. A.1. Encourage those building custom homes to design and construct homes with architectural lines which enable them to harmonize with the surroundings, adding to the community identity and desirability. A.3. Minimize encroachment on view of existing homes by new construction or additions to existing structures. A.4. Support retention and rehabilitation of older housing within Edmonds whenever it is economically feasible. A.S. Protect residential areas from incompatible land uses through the careful control of other types of development and expansion based upon the following principles: A.S. b. Traffic not directly accessing residences in a neighborhood must be discouraged A. 5. d. Private property must be protected from adverse environmental impacts of development including noise, drainage, traffic, slides, etc. A. 6. Require that new residential development be compatible with the natural constraints of slopes, soils, geology, drainage, vegetation and habitat. Compliance with the Residential Development goals and policies: The proposal will allow for the construction of three new single-family homes within City limits. The overall proposal should not cause any adverse impacts and appears to be consistent with the residential development goals and policies of the Comprehensive Plan. The future residences will be reviewed for compliance with applicable critical areas regulations at the time of building permit application review. Traffic impact fees consistent with Chapter 18.82 ECDC will be collected with building permits for each Select Homes Short Plat File No. PLN20170046 Page 4 of 13 additional lot to mitigate traffic impacts. The overall proposal should not cause any adverse impacts and appears to be consistent with the residential development goals and policies of the Comprehensive Plan. Therefore, staff finds that the proposal is consistent with the Comprehensive Plan. Vegetation and Wildlife A. Goal. The city should ensure that its woodlands, marshes and other areas containing natural vegetation are preserved, in accordance with the following policies. - A. I Critical areas will be designated and protected using the best available science (BAS). A.2. The removal of trees should be minimized particularly when they are located on steep slopes or hazardous soils. Subdivision layouts, buildings and roads should be designed so that existing trees are preserved. A. 3. Trees that are diseased, damaged, or unstable should be removed. A.4. Grading should be restricted to building pads and roads only. Vegetation outside these areas should be preserved. Compliance with Vegetation and Wildlife goals and policies: For the purposes of the subdivision, tree retention will be reviewed with the civil improvement plans with the subdivision. As noted below in section II.F. La of this report, aside from immediately surrounding the location of the existing house and associated improvements, the subject site is largely undeveloped and in a natural state with several large trees and unmaintained understory located throughout much of the site. No streams, ravines or other environmental resources are present on the site. The preliminary development plans (Attachment 3) indicate the proposed removal of trees located on the western side of the property along 88"' Ave. W and near the existing structures and driveway as well as those trees within the general area of the necessary short plat improvements (i.e. driveways, utilities, etc.). The preliminary development plans indicate the retention of many of the existing trees located on the portions of the site that will not be impacted by the short plat improvements, particularly those on the eastern portions of the site. Many of these trees, however, will need to be removed for the future development of Lots 2 and 3. For the purposes of the proposed subdivision, tree retention will be reviewed with the civil improvement plans with the subdivision. A condition of preliminary approval is that any tree cutting that is not a hazardous situation and/or not necessary as part of the subdivision improvements shall be reviewed at the time of building permit application review. Any trees retained, including trees located on adjacent properties should be protected during development in accordance with the performance standards in ECDC 18.45.050.H. Any tree cutting on the site is subject to the requirements of ECDC Chapter 18.45, or as amended. With the conditions related to protection of existing trees, staff finds that the proposed subdivision is consistent with the Comprehensive Plan. Select Homes Short Plat File No. PLN20170046 Page 5 of 13 3. Zoning Ordinance. The proposal meets all requirements of the zoning ordinance, or a modification has been approved as provided for in this chapter. The subject property is located in the Single -Family Residential, RS-10 zone, and is therefore, subject to the requirements of ECDC Chapter 16.20. Pursuant to ECDC 16.20.030, development standards of the RS-10 zone are as follows: Minimum Lot Maximum Minimum Minimum Minimum Minimum Zone Area Density' y Lot Width Street Side Rear Maximum Maximum (Sq. Ft.) Setback Setback Setback Height Coverage RS-10 10,000 4.4 75' 25' 10, 20' 25' 35% Density means "dwelling units per acre" determined by dividing the total lot area by the density allowed by the underlying zoning; the number of lots or units permitted shall be rounded down to the nearest whole number. Minimum Lot Area: The subject site is 38,947 square feet. The RS-10 zone requires a minimum net lot area of 10,000 square feet per lot. Proposed lot area is as follows: Proposed Gross sq. ft. Proposed Net sq. ft.* Lot 1 13,880 13,880 Lot 2 11,907 11,907 Lot 3 11,920 11,920 *Note: Net lot area excludes the area of any vehicular ingress/egress easements. However, no such easements are indicated with the proposal. As proposed, the lots exceed the minimum required net area of 10,000 square feet per lot, which is compliant with the minimum lot area requirements. Densi : At 38,947 square feet, a total of 3 dwelling units maybe developed on the subject property (0.89 acre . 4.4 dwelling units per acre). The applicant is proposing to develop the site with three single-family dwellings which is compliant with the density requirements. Lot Width: Pursuant to ECDC 21.55.050, lot width is the minimum diameter of a lot width circle that must fit within a lot (75 feet in this instance). A 75-foot diameter lot width circle fits into each of the proposed lots; therefore the proposal is consistent with the minimum lot width requirement. Select Homes Short Plat File No. PLN20170046 Page 6 of 13 Setbacks: Based on the development standards for the RS-10 zone, setbacks for the proposed lots should be as follows: Lot 1: Street Setback (25 feet) Side Setbacks (10 feet): Lot 2: Street Setback (25 feet) Side Setbacks (10 feet): Rear Setback (20 feet): Lot 3: Street Setback (25 feet) Side Setbacks (10 feet): Rear Setback (20 feet): From the west and north property line. From the south and east property lines. From the north property line. From the east and west property lines. From the south property line. From the north property line. From the east and west property lines. From the south property line. As indicated on the preliminary short plat plans, all existing structures are to be removed. Any future construction on the proposed lots must comply with the setbacks in effect at the time of development. Corner Lots: Lot 1 is considered a corner lot. Flag Lots: None of the proposed lots are considered flag lots. Interior Lots: Lot 2 and Lot 3 are considered interior lots. Lot Coverage of Existing_ Buildings on Proposed Lots: The preliminary development plans (Attachment 3) indicate that all existing onsite improvements are to be removed. Since the existing residence overlaps the proposed property line between Lots 1 and 2, a condition of approval has been added requiring the removal of the existing residence and associated improvements prior to recording of the subject short plat. Following the removal of all existing structures as required by the conditions of approval, there will be no structures located on any of the proposed lots. Pursuant to ECDC 16.20.030, any future buildings or structures on any of the proposed lots may cover no more than 35% of the net area of each lot. Parkin : ECDC 17.50.020 requires a minimum of two on -site parking spaces per single- family dwelling. The two required parking spaces may be tandem. The existing residence and associated structures are proposed to be removed. Compliance with the parking requirements will be required at the time of future development of each of the proposed lots. Staff finds that with the conditions of approval, the proposal is consistent the zoning requirements for the RS-10 zone as contained in ECDC 16.20. 4. Flood Plain Management. The proposal meets all requirements of the Edmonds Community Development code relating to flood plain management. The proposed project is not located within a designated flood plain management area. Select Homes Short Plat File No. PLN20170046 Page 7 of 13 F. ECDC 20.75.085 — Review Criteria. Pursuant to ECDC 20.75.085, the following criteria shall be used to review proposed subdivisions: 1. Environmental. a. Where environmental resources exist, such as trees, streams, ravines or wildlife habitats, the proposal shall be designed to minimize significant adverse impacts to the resources. Permanent restrictions may be imposed on the proposal to avoid impact. Aside from immediately surrounding the location of the existing house and associated improvements, the subject site is largely undeveloped and in a natural state with several large trees and unmaintained understory located throughout much of the site. No streams, ravines or other environmental resources are present on the site. The preliminary development plans (Attachment 3) indicate the proposed removal of trees located on the western side of the property along 88t" Ave. W and near the existing structures and driveway as well as those trees within the general area of the necessary short plat improvements (i.e. driveways, utilities, etc.). The preliminary development plans indicate the retention of many of the existing trees located on the portions of the site that will not be impacted by the short plat improvements, particularly those on the eastern portions of the site. The City promotes the retention of as many trees as practicable and encourages the location of building areas with the goal of retaining as many trees as possible. Although additional trees will need to be removed at the time of development of the proposed lots due to the location of several trees near the center of each of the proposed lots, it appears that some of the existing trees, particularly those located in the south eastern portion of proposed lot 3 could be retained with the future development of the homes on these lots. For the purposes of the proposed subdivision, tree retention will be reviewed with the civil improvement plans with the subdivision. A condition of preliminary approval is that any tree cutting that is not a hazardous situation and/or not necessary as part of the subdivision improvements shall be reviewed at the time of building permit application review. Any trees retained, including trees located on adjacent properties should be protected during development in accordance with the performance standards in ECDC 18.45.050.H. Any tree cutting on the site is subject to the requirements of ECDC Chapter 18.45, or as amended. With the conditions related to protection of existing trees, staff finds that the proposed subdivision is consistent with this criterion. b. The proposal shall be designed to minimize grading by using shared driveways and by relating street, house site and lot placement to the existing topography. The proposal minimizes grading because the portion of the site to be developed is relatively level. Proposed Lots 2 and 3 will each be accessed directly off of 188"' St. SW, and proposed Lot 1 will be accessed directly off of 881" Ave. W. Therefore, staff finds that the proposed subdivision is consistent with this criterion. Select Homes Short Plat File No. PLN20170046 Page 8 of 13 c. Where conditions exist which could be hazardous to the future residents of the land to be divided, or to nearby residents or property, such as flood plains, steep slopes or unstable soil or geologic conditions, a subdivision of the hazardous land shall be denied unless the condition can be permanently corrected, consistent with paragraphs A(1) and (2) of this section. No known hazardous conditions, such as flood plains, steep slopes, or unstable soil or geologic conditions exist at this site. Therefore, staff finds that the proposed subdivision is consistent with this criterion. d. The proposal shall be designed to minimize off -site impacts on drainage, views and so forth. The proposed development must be designed to meet current code and minimize stormwater impacts. All new impervious surfaces must be mitigated on site as required by the Engineering Requirements (Attachment 16). Therefore, staff finds that the proposed subdivision is consistent with this criterion. 2. Lot and Street Layout. a. Lots shall be designed to contain a usable building area. If the building area would be difficult to develop, the lot shall be redesigned or eliminated, unless special conditions can be imposed on the approval which will ensure that the lot is developed properly. All three lots of the proposed subdivision have been designed to accommodate single- family residences within the required setbacks for the RS-10 zone. The subject property is relatively level and should not be difficult to develop. Based on a review of the project and the analysis in this section, staff agrees that a three -lot plat may be developed consistent with this requirement. Therefore, staff finds that the proposed subdivision is consistent with this criterion. b. Lots shall not front on highways, arterials or collector streets unless there is no other feasible access. Special access provisions, such as shared driveways, turnarounds or frontage streets may be required to minimize traffic hazards. Proposed Lots 2 and 3 will take access directly off of 188"' St. SW which is not identified as a highway, arterial or Collector Street in the City's Comprehensive Transportation Plan. Lot 1 will access off of 88"' Ave. W which is a collector street; however, due to the proximity to the school it is preferred by the Engineering Division to reduce the number of access points off of 188"' St. SW. As conditioned staff finds that the proposed subdivision is consistent with this criterion. c. Each lot shall meet the applicable dimensional requirements of the zoning ordinance. The subject property is located within the RS-10 zone. Refer to Section II.E.3 of this report for an analysis of the proposal's compliance with the applicable zoning standards. All three of the proposed lots contain at least 10,000 net square feet and are at least 75 feet in width and thus compliant with the dimensional requirements of the RS-10 zone. Therefore, staff finds that the proposed subdivision is consistent with this criterion. Select Homes Short Plat File No. PLN20170046 Page 9 of 13 d. Pedestrian walks or bicycle paths shall be provided to serve schools, parks, public facilities, shorelines and streams where street access is not adequate. The subject parcel is primarily served by three area schools: Seaview Elementary School, Meadowdale Middle School, and Meadowdale High School. According to information that is made available on the Edmonds School District website (www.edmonds.wednet.edu, accessed on January 4, 2018), bus service is provided to the Middle and High School. The bus stop for service is located at the intersection of 188"' St. SW and 88t" Ave. W. There is no bus pick up or drop off for service to Seaview Elementary School. The subject site is located at the intersection of 188"' St. SW and 88"' Ave. W and is approximately 865 linear feet from the intersection to the Seaview Elementary school property boundary. According to the Edmonds School District website, a suggested routes map shows the route along the south side of 188"' St. SW. 18811, St. SW currently provides sidewalk up to the school along the south side of the street. A 5-foot concrete sidewalk built to City standards is required along 188"' St. SW and 881" Ave. W. adjacent to the subject site. With this condition which is confirmed in the Engineering Requirements (Attachment 16) staff finds that the proposed subdivision is consistent with this criterion. 3. Dedications a. The city council may require dedication of land in the proposed subdivision for public use. b. Only the city council may approve a dedication of park land to satisfy the requirements of ECDC 20.75.090. The council may request a review and written recommendation from the planning advisory board. c. Any approval of a subdivision shall be conditioned on appropriate dedication of land for streets, including those on the official street map and the preliminary plat. Per the City Engineering Division requirements (Attachment 16), a 10-foot right-of-way dedication to the City is required along the property frontage on 88"' Ave. W. See Section II.G below regarding the dedication of park land. 4. Improvements. a. Improvements which may be required, but are not limited to, streets, curbs, pedestrian walks and bicycle paths, sidewalks, street landscaping, water lines, sewage systems, drainage systems and underground utilities. b. The person or body approving a subdivision shall determine the improvements necessary to meet the purposes and requirements of this chapter, and the requirements of.- i. ECDC Title 18, Public Works Requirements; ii. Chapter 19.75, Fire Code, as to fire hydrants, water supply and access. This determination shall be based on the recommendations of the community development director, the public works director, and the fire chief. The subject proposal was reviewed by Snohomish County Fire District No. 1 and the Public Works Department - Engineering Division. Improvements required in conjunction with the subject proposal are included in Attachment 16. Select Homes Short Plat File No. PLN20170046 Page 10 of 13 With the conditions of approval referring to the Engineering Requirements provided in Attachment 16, staff finds that the proposed subdivision is consistent with this criterion. c. The use of septic systems may be approved if all of the following conditions are met: i. It is more than 200 feet, multiplied by the number of lots in the proposed subdivision, from the nearest public sewer main to the nearest boundary of the land to be divided. ii. The land to be divided is zoned RS-20. iii. The public works director and city health officer determine that soil, drainage and slope conditions are satisfactory for septic use and that all requirements of WAC 248-96-090 are met. There are no septic systems included as part of the proposed project. Water and sewer service at the site is provided by the City of Edmonds. 5. Flood Plain Management. All subdivisions shall comply with the criteria set forth in the Edmonds community Development code for flood plain management. The subject property is not located within a Flood Plain Management area. G. ECDC 20.75.090 — Park Land Dedication. According to ECDC 20.75.090, before or concurrent with the approval of the final plat of any subdivision, the subdivider shall dedicate land, pay a fee in -lieu of dedication, or do a combination of both, for park and recreational purposes. With the adoption of Ordinance 3934 in 2013, park impacts are now addressed through the assessment of park impact fees in accordance with Edmonds City Code (ECC) Chapter 3.36. No park dedication or fees are required with the subdivision. Park impact fees will be assessed with issuance of the building permits on the new lots consistent with ECC Chapter 3.36. III. DECISION ON SUBDIVISION Based upon the Findings of Fact, Conclusions, and Attachments to this staff report, the application for a three -lot short plat on the property located at 18807 18811, St. SW. is APPROVED subject to the following conditions: 1. This application is subject to all applicable requirements contained in the Edmonds Community Development Code (ECDC). It is the responsibility of the applicant to ensure compliance with all applicable requirements. 2. The applicant is responsible for obtaining all local, state, and/or federal permits or approvals applicable to the proposal. 3. Any tree cutting on the site must be consistent with the requirements of ECDC Chapter 18.45. Additionally, all trees retained during the development process and trees located on adjacent properties must be protected according to the performance standards found in ECDC 18.45.050.H. 4. Prior to recording, the applicant must complete the following requirements: a. Remove the existing residence and associated structures. Obtain all necessary permits from the Building Division for the demolition of these structures prior to conducting such work. b. Civil plans must be approved prior to recording. In completing the civil plans, you must address the following: Select Homes Short Plat File No. PLN20170046 Page 11 of 13 i. Complete the Engineering Division conditions listed "Required as a Condition of Subdivision" on Attachment 16. ii. A tree cutting plan shall be submitted and approved with the civil plans for removal of trees impacted by the subdivision improvements. Any tree cutting proposed on the site that is not a hazardous situation and/or not necessary as part of the subdivision improvements shall be reviewed at the time of building permit application or through the appropriate land use permit application and review process. All trees that are to be retained during the development process and trees located on adjacent properties must be protected according to the performance standards found in ECDC 18.45.050.H. Make the following revisions to the plat: i. Ensure that all existing easements are indicated. ii. Indicate the locations of all new easements, and provide easement descriptions and maintenance provisions for all new easements. iii. Add to the face of the plat: "Conditions of approval must be met and can be found in the approval for the short subdivision located in File No. PLN20170046 in the City of Edmonds Planning Division." iv. Include on the plat all required information, including owner's certification, hold harmless agreement, and Development Services and Public Works director's approval blocks. d. Make sure all documents to be recorded meet the Snohomish County Auditor's requirements for recording. e. Submit an updated copy of the title report (short plat certificate) with the documents proposed to be recorded. The title report must be prepared within 30 days of submittal for final review. f. Submit two copies of the documents to be recorded for the Planning Division and Engineering Division's approval. Once approved, the documents must be recorded with the Snohomish County Auditor's office. 5. After recording the plat, the applicant must complete the following: a. Complete the Engineering Division conditions listed "Required as a Condition of Building Permit" in Attachment 16. IV. APPEAL Pursuant to ECDC 20.07.004, a party of record may submit a written appeal of a Type II decision within 14 days after the date of issuance of the decision. The appeal would be heard at an open record public hearing before the Hearing Examiner according to the requirements of ECDC Chapter 20.06 and Section 20.07.004. V. LAPSE OF APPROVAL Section 20.75.1.00.13 states, "Approval of a short plat shall expire and have no further validity at the end of seven years if preliminary short plat approval is issued on or before December 31, 2013, and five years if preliminary short plat approval is issued on or after January 1, 2014, unless the applicant has acquired final short plat approval within the specified time period." Since preliminary approval has been after January 1, 2014, this preliminary short plat approval shall be valid for five years from the date of this staff report. Select Homes Short Plat File No. PLN20170046 Page 12 of 13 VI. NOTICE TO COUNTY ASSESSOR The property owner may, as a result of the decision rendered by the staff, request a change in the valuation of the property by the Snohomish County Assessor's Office. VII. PARTIES OF RECORD City of Edmonds 121 — 5"' Ave. N Edmonds, WA 98020 Kayla Clark Select Homes, Inc. 16531 — 13"' Ave. S, Suite A107 Lynnwood, WA 98037 VIII. ATTACHMENTS Anjum Hajat 8829 188"' St. SW Edmonds, WA 98026 1. Land Use Application and Cover Letter 2. Preliminary Short Plat Plans, received 12/14//17 3. Preliminary Development Plans, received 12/14/17 4. Zoning and Vicinity Map 5. Storm Drainage Report, Received 12/14/17 6. EUC Forms and Correspondence from Puget Sound Energy 7. Letter of Complete Application, dated 10/24/17 8. Public Notice Documentation 9. Letter of Request for Additional Information 11 /9/ 17 10. Resubmittal Cover Letter, received 12/14/17 11. Fire District No. 1 Comment Form 12. Public Work's Comments -1 13. Building Division Comment Form 14. Public Comment Letter 15. Applicant's Response to Comments, received 9/13/17 16. Engineering Approval Memorandum and Requirements for Short Plat Select Homes Short Plat File No. PLN20170046 Page 13 of 13