Loading...
Response to BLD Comments 1.pdf8/13/2016 JAMES -ANDERSON =7ESICGN P.S. RE5/17ENTIAL ARCHITECTURE 19626 76TH AVE. K 5TE. A LYNNWOOD,`AA 98036 PHONE 425-776-6766 City of Edmonds Building Division RE: BLD2015-0794 Chuck, I have reviewed your corrections and have modified or clarified the following items: 1a) Changed wording on sheet 1, ( P) 1. 1b) Changed the wording on sheet 1, (Q)2 1c) Changed the wording on sheet 1, (Q)4 1d) Changed the wording on sheet 1, (U)20. 2a) 1Ne had to cut 2' off the depth of the covered patio for setback reasons, so I have included the new beam calcs(B-2) and gravity load calculations for the embedded post. Both meet requirements. 2b) 5hear transfer through concrete occurs at approximately a 1:1 ratio throughout the height of the concrete wall (no reinforcement, worst case.) Therefore with an 18" minimum stem wall, a 6" minimum footing and (2) 2X4'5, it will transfer the load across 53" of footing (24" + 3" post.) 5o.... 4.25 X 1= 4.25 X 2000 #/5q ft = 8500# allowable. The reaction at the end of the girder truss is 7200# which is < 8500 therefore is allowed. Sketch included. 2c) I have widened the footing across the garage front to 16" to accommodate the load. 3a) 5afety glazing is not required in storage closets less than 3' or less in depth per 8308.4.2. I have dimensioned the closet to be less than 31-011. '-O". 3b) T5(5 has been noted on the dining window. 3c) A UA alternative worksheet has been completed and enclosed. 3d) Has been duly noted on sheet 4. CATHERINE ANDER50N ARCH I MAMA„@,,,M„5,N,,,,,G,OM, 4a) I have the E and W elevations fixed, got them mixed up. The window is a 5'X 4' on the east side. 4b) 5ame as above. 4c) Have noted on sheet 5 and have submitted calcs. 4d) At dining room I have added a note and provided calcs. The living room end of the girder actually lands on a beam, but have added a note at end of beam and provided calculations. 4e) I have added a note and provided calcs for both beam and column on each side of header. 4f) Have noted on sheet 5 and have submitted calcs. 4g) I have the E and W elevations fixed, got them mixed up. It is a 3'-9" X 31-611. 4h) I did not calculate columns with minimal loading. This one had only 1076# which is easily taken care of with normal framing with a king stud and cripple (2-2X4 total.) Calculations represent a worst case. 40 1 did not calculate columns with minimal loading. This one had only 175"7# which is easily taken care of with normal framing with a king stud and cripple (2-2X4 total.) Calculations represent a worst case. 4j) I did not calculate columns with minimal loading. This one had only 1757# which is easily taken care of with normal framing with a king stud and cripple (2-2X4 total.) Calculations represent a worst case. aid , thy erson .. 425-776-6766 CATHERINE ANDER5ON ARCH W„I,M„AMA@ MSN .COM,