Response to BLDG Comments 1 BLDG A.pdfR E S U B JUN 0 7 2018 al)ILDINGDEPARTWCOmment Response Date: June 6, 2018 To: Chuck Miller, Senior Plans Examiner, City of Edmonds From: Thaddeus Egging, KPFF and Joseph Mangan, Pacific Mobile Project Engineer Subject: Sherwood Elementary School Portable Classroom "B" (Permit # BLD2018-0471) Comment Responses The following comment responses are in response to Building Plan Review comments dated May 11, 2018 prepared by Chuck Miller (attached for reference): 1. COMMENT: On Sheet G0.0-Cover Sheet: Site Plan -Locate on the plans between `Building Unit C' and the relocatable classroom the `imaginary line' to be used to determine the exterior wall and opening protection set forth in International Building Code (IBC) Sections 705.5 and 705.8 per IBC 705.3. RESPONSE: Refer to revised Sheet G1.0 (attached) for fire separation imaginary line (assumed property line) between Building Unit C and relocatable classroom B. The fire separation/assumed property line is drawn 10 feet from existing Building Unit C based on the following IBC requirements: IBC 705.3 specifies "Where a new building is to be erected on the same lot as an existing building, the location of the assumed imaginary line with relation to the existing building wall shall be such that the exterior wall and opening protection of the existing building meet the criteria a set forth in Section 705.5 and 705.8." IBC 705.5 requires the fire resistance rating of the exterior walls to be rated for exposure to fire from the inside if the fire separation distance is greater than 10 feet or rated for exposure to fire from both side if the fire separation distance is less than or equal to 10 feet. Conservative assumption that the existing Building Unit C exterior wall is rated for fire exposure from the inside requires the fire separation distance to be greater than 10 feet. IBC 705.8 allows a maximum area of exterior wall opening of 15% for an unprotected, nonsprinklered building with fire separation distance of 10 to less than 15 feet. Building C exterior wall opening is approximated at 14.95%, conforming to the maximum wall opening area for the given fire separation distance. 2. COMMENT: On Sheet A20.1-Pacific Mobile Foundation Designs: Clarify on the plans the difference in the represented construction/connections and of that specified in the provided structural calculations. Of particular concern are the lateral design elements noted in Division 'II'— Foundation Design — Section 'E' — Lateral Design — of the calculations that to not appear on the plans. RESPONSE: Differences between the submitted calculations page and foundation drawing (A20.1) have been resolved. See revised A20.1 and structural calculations (attached). Specific resolutions are highlighted and explanations given in clouds. Note A highlights 7/16" sheathing prescribed by the calculations page while thicker'/z" sheathing is described in the drawing. The note also points to the calculations having 16" o.c. fastener spacing while the plans show 12" o.c. The thicker sheathing and closer fastener spacing should provide more strength and not be a problem. Note B highlights 5/8" diameter anchor bolts on both the calculations and drawings page. The drawing Citv of Edmonds PLAN REVIEW COMMENTS BUILDING DIVISION (425) 771-0220 DATE: May 11, 2018 TO: Will Thomsen thomsenW((L,)edmonds.wednet.cdu FROM: Chuck Miller, Senior Plans Examiner chuck.millcr((t?cdmondswa.gov RE: Plan Check: BLD2018-0471 - I" review Project Address: 22901 106th Avenue W Project: ESD Sherwood Elementary relocatable classroom `B' Scope: Siting, connection, support, and lateral restraint of manufactured classroom structure — nonseparated Education Group E occupancy — 42 occupants — VB construction — no sprinkler system — fire alarm under separate permit Please be advised that the building plans for the above referenced project have been disapproved for the purposes of obtaining a building permit. During a review of the plans by the Building Division for compliance with the applicable building codes, it was found that the following information, clarifications, or changes are needed. Reviews by other divisions, such as Planning, Engineering, or Fire, may result in additional comments that require attention beyond the scope of this letter. A complete review cannot be performed until the revised plans/documents, including a written response in itemized letter format indicating where the `clouded' or otherwise highlighted changes can be found on the revised plans, have been submitted to a Permit Coordinator. Only those sheets specifically referenced as follows need to be resubmitted. Resubmittals must be made at the Development Services Department on the 2nd Floor of City Hall. Permit Center hours are M, T, Th, & F from 8am-4:30pm and from 8:30am-12pm on Wednesdays. On sheet G0.0 — Cover Sheet: 1. Site Plan — Locate on the plans between `Building Unit C' and the relocatable classroom the `imaginary line' to be used to determine the exterior wall and opening protection set forth in International Building Code (IBC) Sections 705.5 and 705.8 per IBC 705.3.