Loading...
response to bldg comments 1.pdfAdair Enterprises, LLC 15922 East Shore Drive Lynnwood, WA 98087 (206) 799-6229 September 13, 2016 City of Edmonds Chuck Miller Plan Review/Building Division Re: Plan Check: BLD2016-0875 Project Address: 10114 243rd Pl SW Project: Nelson SFR Response to letter dated August 29, 2016 aol cwt wi emy 1 —1) E '�% +Iaum IPk NOV 01 DING ���� The following are the itemized responses to the disapproval letter for the above-mentioned project. 1.a. Changes are on page 2 of the plan set located over the 16' slider location. 1.b. Roof detail has been added to page 5 of the plan set on the right hand side. Should you have any other questions please let me know. Thanks, Win Lessley Adair Enterprises, LLC (206) 799-6229 C10 D f Edmonds BUILDING DIV[SION' (4151, 771 �022k) DATE: August 29, 2016 TO: Adair Enterprises, LLC 4 to ill mmix,:�,,_UUn ac, xwn, FROM: Chock Miller, Plans Examiner RE- Plan Check-, BLD2016-0875 Project Address: 10114 243d Place SW Project. Nelson SFR Scope- Construct single family residence — R -3/U occupancy group — V -B construction - NFPA­ I 3D sprinkler system required- mechanical and plumbing included Please be advised that the building plans for the above referenced project have been disapproved for the purposes of obtaining a building permit. During a review of the plans by the Building 1)ivision t`6r compliance with the applicable building cotes„ it was found that the following infonnation, dalifications, orchariges are nerded. Reviews byadder divisions, stichas Plantiing, Engineering, or Fire, may result in additional comments that require attention beyond the scope of this ICU", A complete, review cannot be performed until the written reswitse lit I emized llette'-r, tornud Indicatina where t,hi tdou#A" or otherwiw highilloftA c1langes can be fqmid og,thettli. 4 la tri,, have been submitted to a Permit Coordinator. Resubmittals must be made at the Development Services Department on the 2"d Floor of City Hall, Permit Center hours are M, T. Th, & F from 8am-4:30pm and from 8:30am- I 2pm on Wednesdays. On sheet 5: 1. Roof Plan a. Indicate on the plans the minimum required beam to support the loads over the 16.0x8.0 sliding glass doom in the 'plan -south' wall of the 'Family' room, The 4"A ,typical' 4x10 DF #2 appears to fail in bending and in shear and deflects beyond that allowed per International Residential Code (IRC) Table 8301.7. b, Indicate on the plans the proposed placement of the 2x 10 BF #2 rafters for the "flat L c) c i\ porch roof at the `plan -cast' side of the 'Dining' room, Of particular concern is the tributary loading of the various 5-1/40-1/4 PSU and the members supporting them.