Loading...
response to bldg comments 1.pdfEIII . Wmkk i. VA_C�2_ C ) Structural Comments MAR 10 2016 11. Detail 5 shows a concrete curb to be poured up providing the required sepa9RTdW' ' r & existing grade and the wood elements used to construct the wall above. However, there is no connection shown between that curb and the garage slab below. There should be some connection between the two elements to ensure they 12. Revise the elevations to show the upper floor cantilevered over the front of the garage. 13. It is shown on the 1st Floor Demo Plan that the interior end of the central floor beam over the garage bears adjacent to an existing door that is to be removed. With the removal of that portion of wall, indicate how that end of the beam will be supported. 14. It appears that a new window is to be added in Bedroom D. The remainder of that wall line does not appear to meet the requirements of IRC Chapter 6 for a prescriptive design. Either clarify how the submitted design meets the prescriptive requirements or provide lateral calculations stamped by an engineer licensed in the State of Washington. RESPONSE: 1. Demo plan and proposed 1 st floor plan have been clearly annotated to show existing and proposed walls. 2. 2nd floor bedrooms has been annotated on sheet A-200 to show that bedrooms are not be used for Adult Family Home, 3. 1 st Floor plan has been revised to show the location of HVAC & water heater. 4. Notes has been added in Sheet A-200 regarding the requirements for Adult Family Homes 5. Garage exterior wall are furred -out to accommodate exterior wall R -value (21). See detail 3/A-300 6. Whole house ventilation to be installed on 1 st Floor Bathroom. See Floor plan on Sheet S-200 7. Plan has been noted that the structure will be "R-3 - Adult Family Home" on Sheet A-200 8. Window has been annotated to have a safety glazing on 1st floor plan in Sheet A-200 9. New and relocated plumbing has bee noted and identified on sheet A-200 10, 3" Rigid insulation will be used in 2x4 furring wall to achieve R-21 value. See detail 3/A300 11. Detail 5 on sheet A-300 has been revised to show connection detail. 12. Elevations on sheet A-400 has been updated to show the cantilever over the front of garage 13. 4X6 Post has been added to support end of beam. See floor plan on Sheet A-200 14. Location of window has been revised to meet prescriptive requirements. Page 2 of 2