RESPONSE TO BLDG COMMENTS 3.pdfResponse to The Plan Review Comments dated 9/19/2016 9/22/2016 RE: Plan Check, BLD20�16-966 No.) B Project A,ddre a: 22923 Highway 99, Suite J SEP 2 2 201 Project: Fashion Dim Sulam TI ,hUILI)HNG DEAl"ITMEvN On sheet FS -1— Equipment Plan: 1. Equipment Schedule 1- Indicate on the plans the required installation of Type II hoods above the following appliances that produce heat or moisture per International Mechanical Code (IMC) 507.2.2: Mark 110'— Cabinet Heater/Proofer . Mark'14' — Electric 3 Pan Steam Table An HVAC system design that incorporates the heat and moisture loads from the appliances or a separate removal system are acceptable alternatives that must be noted on the plans. Spaces containing cooking appliances without Type II hoods shall be provided with exhaust at a rate of 0.70 CFM per square foot. The response to the plan review comment states: "Revised. Exhaust at a rate of 0.70 CFM added.". The proposed exhaust rate does not meet the requirements of IMC 507.2.2. As noted in the earlier plan review, the spaces containing cooking appliances without Type II hoods shall be provided with exhaust at a rate of 0.70 CFM per square foot. Mark'10' — Cabinet Heater/ /roofer. 32.25"Wx 22"D = 709.5 sq.in= 4.93 sq.ft. .93 sq.ft. x 0.7 CFM = 3.45 CFM. Revised note added on Ian: Exhaust vent at 35 CFM minimum • Mark `14' — Electric 3 Pan Steam Table, 4.25"W x 22.5"D = 995.63 sq.in =6.9sq. V9 sq,ft. x 0.7 CFM = 4.84 CFM Revised note added on lan: Exhaust vent at 35 CFM minimum On sheet FS -2 —Plumbing: dded to the resubmittal dated 'September 2, 2016' — 2. Clarify on the plans the note a "PLEASE BE ADVISED: PLUMBING PERMIT WILL BE OBTAINED BY THE PLUMBER". The 'General Notes' on sheet 'A-0' —Cover Page -the plumbing supply/drain/waste/vent information on sheet 'FS -2 — Plumbing - and the line drawing representing the proposed plumbing supply/drain/waste/vent system on sheet 'FS-2.1— appear to include and represent a proposed plumbing installation. References to a plumbing installation should be eliminated from the scope of work and provided construction documents if the work is to be completed under a separate permit, or be identified as 'Reference Only'. Even if identified as 'Reference Only', the plans must represent the proposed work consistently with that under the separate permit. "PLEASE BE ADVISED: PLUMBING PERMIT WILL BE OBTAINED BYTH PLUMBERS Note has been cross off, On sheet FS-2.1—Plumbing Rough -in: osed installation of the fixtures required to drain to the grease 3. Clarify on the plan the prop traps, and of the grease traps. Fixtures indirectly draining to floor sinks would require that the grease trap be installed lower than the floor sink to maintain the minimum required slope. In typical installations where the grease trap is placed on the floor, the fixtures drain into the grease trap, which then indirectly drains to a floor sink. sketch of the proposed installation has been included with this letter 115""144R t'lo J.,,, 0 115""144R t'lo J.,,,