Response to Comments from Arch to Plan, Eng, Bldg (2).pdfV z WATTEN BAR%'r itects_ August 1, 2016 City of Edmonds Development Services Department 121 5th Ave N Edmonds, WA 98020 Re: Review comments, BLD2016-0561 2100 112th Ave NE #100 Bellevue, WA 98004 t:425-453-0606 f:425-453-4772 IIG 2016 I am writing in response to comments received for the building permits for the Willowdale Townhomes project. The following summarizes the changes that have been incorporated into the construction documents to address the review comments from city staff. Original grade: On Sheet A03, show the lines of original topography prior to redevelopment. New building height and lot coverage diagram has been added to sheet A03, and includes the requested topography lines. 2. Smallest rectangle: On Sheet A03, revise the height calculations to use the smallest rectangle that encloses each building, including any building overhangs and projections. Use the updated corner locations to recalculate the average original grade for each building. Bounding rectangle & corner point elevations have been added to the above referenced diagram. Average grade calculations are provided for each building. 3. Elevation lines: On Sheets A10 and All, use the revised calculations from #2 above and show the lines of 'average original grade, 'maximum allowed height, and 'proposed' or 'actual' height on the elevation drawings. Average original grade, maximum allowed height & proposed height are now shown on exterior elevation drawings. 4. 4:12 roof.• On Sheet A07, show that the roof pitches are at least 4:12 pitch for those portions of roof above 25' in accordance with ECDC 16.30.030.A sub 1. 2100 112th Ave NE Suite 100 • Bellevue, WA 98004 • (425) 453-0606 • FAX (425) 453-4772 . www.wattenbarger.com Erroneously omitted slope arrows have been added. Slope is to be 5:12 at roofs taller than 25% exceeding the code requirement. 5. Site data: Please copy the "Site Data" from Sheet A01 and add it to Sheet A03. Site data has been added to sheet A03. 6. Lot coverage: On Sheet A03, provide the lot coverage for each structure and the total coverage for all four structures as a percentage of the total lot area. Per ECDC 21.15.110,"[c]overage means the total ground coverage of all buildings or structures on a site measured from the outside of external walls or supporting members or from a point two and one-half feet in from the outside edge of a cantilevered roof, whichever covers the greatest area." Lot coverage calculations have been added to sheet A03. Engineering Department Review Comments: 1. Submit a temporary erosion and sediment control plan. Site development shall be per previously reviewed and approved plans. TESC plan from original permit is included for reference. 2. Submit a utility plan clearly indicating all existing and proposed utilities and required utility separation. Dry utilities shall also be shown. Indicate meter size, pipe size, depth and invert elevations to confirm new connections to existing systems will meet minimum slope requirements. Site development shall be per previously reviewed and approved plans, copies of which have been included for reference. 3. Provide an Impervious Surface Area chart consistent with that provided in City handout E72. An Impervious Surface Area Chart has been included on sheet A03 and is consistent with City handout E72 and the Revised Stormwater Analysis dated 2/3/16 and previously submitted by Barghausen Consulting Engineers, Inc 4. Show tightline around the buildings and connection to the on-site storm detention system. Conceptual footing drain and downspout tightline have been added to the architectural site plan. Storm plan from original permit is included for reference; connection information is also shown on sheet C7. 5. Clearly distinguish between existing conditions and those improvements that are to be constructed under this permit (trash enclosure, on-site sidewalk, etc.). Provide details for elements to be constructed as applicable. 2100 112th Ave NE Suite 100 ® Bellevue, WA 98004 • (425) 453-0606 • FAX (425) 453-4772 • www.wattenbarger.com All remaining site improvements to be completed have been noted on a copy of the previously reviewed and approved plans, a copy of which has been included for reference. R. � On sheet A01 — Project Data: 1. Project Data — Occupancy Classification (and on the City of Edmonds 'Commercial & Multi -Family Building Permit Application - Form E') - Clarify the difference in the indicated occupancy classification of the proposed structure and of that regulated under the scope of the International Residential Code (IRC) per International Building Code (IBC)101.2. Note #1 of the 'General Notes' on sheet 'A01' and other notes in the following sheets appear to designate the IRC as the intended regulatory code governing the construction of the proposed structure. Reference to IBC occupancy classifications have been removed; replaced with "IRC 'Townhouse"'. On sheet A02 — Code Compliance: 2. Applicable Codes -Clarify the difference in the indicated regulatory code governing the mechanical systems of the proposed structure and of that regulated under the scope of the International Residential Code (IRC) per International Building Code (IBC)101.2. References to IMC & UPC have been removed from sheet A02; it is our intent that mechanical systems are to be governed by the IRC. 3. Building Code Analysis — IRC Section R310 —Emergency Escape Openings —Change on the plans the maximum measuring point above the floor for the emergency escape and rescue opening from 'sill' to "bottom of clear opening' per IBC 1029.3 and IRC R310.1. Correction added to sheet A02. On sheet A04 — First Floor: 4. First Floor Plan — Left— Clarify the elevation callout for detail 7 on sheet 'A17' for the 'powder rooms' in 'Unit 01' and 'Unit 03'. There does not appear to be an applicable detail on that sheet, or on sheet 'A15'. Interior elevation 15/A15 has been added to the drawings; callouts from units 01 & 03 powder rooms have been updated accordingly. 5. Wall Type Schedule a. Clearly indicate on the plans the location and the extent of the required fire - resistance rated wall construction between the dwelling units per IBC 420.2 and IRC R302.2. 2100 112th Ave NE Suite 100 • Bellevue, WA 98004 ® (425) 453-0606 • FAX (425) 453-4772 ® www,wattenbarger.com Erroneously omitted wall designations have been added to the floor plans. b. Change on the plans the referenced sheet for the construction criteria of the fire- resistance rated wall from 'A17'to 'A13'. Reference has been revised to read sheet A13.. On sheet A05 — Second Floor: 6. Second Floor Plan — Left a. Indicate on the plans the required safety glazing for the windows marked 'C' in 'Bath #1' of 'Unit 01' and marked 'C1' in 'Bath #1' of 'Unit 03' per IBC 2406.4.5 and IRC 308.4.5. Windows at bath 1 have been corrected to both be window type Cl; window schedule has been updated to require safety glazing at window type C1. b. Clarify on the plans the difference in the proposed 'open to below' floor plan and of that anticipated by the indicated framing members in the area over the 'Entry' and stairs on sheet 'S5'. This area appears to have been shown incorrectly on the structural drawings. Corrections have been made to main floor above framing plans. 7. Wall Type Schedule a. Clearly indicate on the plans the location and the extent of the required fire - resistance rated wall construction between the dwelling units per IBC 420.2 and IRC R302.2. Erroneously omitted wall designations have been added to the floor plans. b. Change on the plans the referenced sheet for the construction criteria of the fire- resistance rated wall from 'A17' to 'A13'. Reference has been revised to read sheet A13. On sheet A06— Third Floor: 8. Wall Type Schedule a. Clearly indicate on the plans the location and the extent of the required fire - resistance rated wall construction between the dwelling units per IBC 420.2 and IRC R302.2. Erroneously omitted wall designations have been added to the floor plans. b. Change on the plans the referenced sheet for the construction criteria of the fire- resistance rated wall from 'A17' to 'A13'. 2100 112th Ave NE Suite 100 ® Bellevue, WA 98004 • (425) 453-0606 ® FAX (425) 453-4772 • wwwmattenbarger,com Reference has been revised to read sheet A13. On sheet A07— Roof Plan: 9. Roof Plan —Clarify on the plans the represented location of the upper ventilators for the attic area over 'Unit 02'. They do not appear to meet the requirements for the reduction of the minimum net free ventilation area to 1/300 of the area of the vented space per IBC 1203.2 and IRC R806.2. All roof venting has been reviewed and revised to comply with the provisions of IRC R806.2. On sheet A08 — 2nd & 3rd Floor Reflected Ceiling: 10. Second Floor Reflected Ceiling Plan a. Indicate on the plans the required minimum exhaust ventilation for 'Bath #1' of 'Unit 01' and 'Bath #1' of 'Unit 03' per IMC Table 403.3 and IRC M1507.4. Minimum cfm requirements have been added to the plans at bath fans. b. Indicate on the plans the required carbon monoxide alarm in 'Unit 02' per IBC 908.7 and IRC R315.1. Carbon monoxide detector requirement added to floor smoke detector at unit plan 'B', second floor location. On sheet A10 — Exterior Elevations: 11. Keynotes —Crawl Space Venting a. Eliminate from the plans the specified vent location at the building corner per the referenced code section. The requirement to place an opening for under floor ventilation with 3' of the building corner does not appear in Section R408.1 (or elsewhere) in the 2012 /RC. Note removed. Crawl space venting calculations revised to 1 SF / 300 SF per R408.1 requirements. b. Indicate on the plans the required installation of a 'radon vent' when the installed openings for under floor ventilation are less than 1/300 of the underfloor area per IBC 1203.6.2.2 and IRC R408.2. Crawl space venting calculations revised to 1 SF / 300 SF per R408.1 requirements, therefore radon venting not required. On sheet A11— Exterior Elevations: 2100 112th Ave NE Suite 100 • Bellevue, WA 98004 • (425) 453-0606 • FAX (425) 453-4772 • www.wattenbarger.com 12. Back Elevation — Clarify the represented location of the fireplace flue termination cap'— mark `P'— at the lower level 'plan left' of the structure. It does not appear to meet the requirements of IMC 804.3.4 and IRC 1804.2.6. Exhaust cap was erroneously shown twice. The location shown too close to the adjacent window was not intended and has been removed. 13. Keynotes — Crawl Space Venting a. Eliminate from the plans the specified vent location at the building corner per the referenced code section. The requirement to place an opening for under floor ventilation with 3' of the building corner does not appear in Section R408.1 (or elsewhere) in the 2012 /RC. Note removed. Crawl space venting calculations revised to 1 SF / 300 SF per R408.1 requirements. b. Indicate on the plans the required installation of a 'radon vent' when the installed openings for under floor ventilation are less than 1/300 of the underfloor area per IBC 1203.6.2.2 and IRC R408.2. Crawl space venting calculations revised to 1 SF / 300 SF per R408.1 requirements, therefore radon venting not required. On sheet A13 — Fire Resistant Construction: 14. Detail 1 — Party Wall B — Roof Step a. Clarify on the plans the indicated 'gridline' for the applicability of the provided detail. It does not appear to correspond with those indicated on sheets 'A04 , `A05; 'A06; and 'A07'. Section detail bugs have been added to sheets A06 & A07 indicating intended location. b. Provide on the plans the construction criteria for the referenced one- hour fire- resistance rated Gypsum Association wall design 'WP5512'. Erroneously shown WP3820 has been removed and replaced with assembly details for WP5512. 15. Detail 4 — Party Wall B — 2 -Hr Rated a. Clarify on the plans the indicated 'gridline' for the applicability of the provided detail. It does not appear to correspond with those indicated on sheets 'A04 , `A05; 'A06; and 'A07'. Intended location for this wall section is indicated on building section 1/Al2. b. Provide on the plans the construction criteria for the referenced one- hour fire- resistance rated Gypsum Association wall design 'WP5512'. 2100 112th Ave NE Suite 100 • Bellevue, WA 98004 • (425) 453-0606 ® FAX (425) 453-4772 • www„wattenbarger,com Erroneously shown WP3820 has been removed and replaced with assembly details for WP5512. On sheet A14 — Wall Sections: 16. Detail 1— Wall Section at Entry Porch — Unit Type W- Change on the plans the referenced sheet for the construction criteria of the fire -resistance rated ceiling construction from `A15' to 'A13'. Sheet reference has been corrected. 17. Detail 2 — Wall Section at Entry Porch — Unit Type 'B' a. Change on the plans the referenced sheet for the construction criteria of the fire- resistance rated ceiling from 'A15' to 'A13'. b. Change on the plans the referenced sheet for the construction criteria of the 'door sill pan at balcony door' from 'A18' to 'A16' c. Change on the plans the referenced detail on sheet 'A17' for the construction criteria of the false balcony' from '16' to '15'. Sheet references has been corrected. On sheet S5 — Main Floor Shearwalls & Framing Above: 18. Main Floor Shearwalls & Framing Above a. Indicate on the plans the required hold-down at the 'plan east' end of the 'SW B6'shearwall on the 'plan east'side of the window in the 'Dining' area of 'Unit 01'. b. Indicate on the plans the required construction to support the load below the 'plan west' end of 'Beam 2-3'— 6-3/4x9 GLB 24F -V4. c. Clarify on the plans the difference in the indicated framing members in the area over the 'Entry' and stairs and of that anticipated by the proposed 'open to below' floor plan on sheet 'A05'. d. Clarify on the plans the callout for the 'HDR'- (2)2x6 beam - over the 'plan south' door in the 'Entry' of 'Unit 02'. It appears to be over spanned and fails in bending. Beam calculations for 'Beam 1-17' could not be found among the submitted construction documents. e. Clarify on the plans the callout for 'Beam 1-10'— 4x8 - over the 'plan north' windows in the 'Dining' areas of 'Unit 01' and 'Unit 03'. It appears to be over spanned and fails in bending. The loads from the 'upper'roof do not appear to have been accounted for in the provided structural calculations. On sheet S6 — Upper Floor Shearwalls & Framing Above: 19. Upper Floor Shearwalls& Framing Above a. Clarify on the plans the callout for the 'HDR'- (2)2x6 beam -over the 'plan south' window in the 'Living Room' of 'Unit 02'. It appears to be over spanned, fails in bending and in shear, and deflects beyond that permitted per IBC Table 1604.3 and IRC Table R301.7. 2100 112th Ave NE Suite 100 • Bellevue, WA 98004 ® (425) 453-0606 • FAX (425) 453-4772 • www.wattenbarger.com Sincerely, b. Clarify on the plans the callout for the 4x4 post below the 'plan west' end of 'Beam 2-4'— 5-1/8x9 GLB 24F -V4. It appears to be undersized for the loads indicated in the provided structural calculations. t Travis McDanold, AIA Wattenbarger Architects Cc: Pacific Ridge Homes File 2100 112th Ave NE Suite 100 • Bellevue, WA 98004 • (425) 453-0606 • FAX (425) 453-4772 • www.wattenbarger.com