TO. "Ronald Johnson" < ronryi ai le@corn cast, rm I>
Sent- Thursday, March 15, 20121-2 3 PM
SuNect. BLD20110808 - McDonald .-'9921 Water St Alit�',,,, 6,t"I
Ron,
I need the following iterns added/corrected on the Civil Drawings.
Show the rirTI/invert elevations for the connection of the new sewer rnain to the existing manhole. As long
as the proposed sewer main has a miniiTiurn of, 4' of cover and a slope of 2% you may show the.new
connection at any elevation with a drop system in place. Reference the drop detail E6.5 which is to be
used for the conriection of ti -ie new sewer regain to the exisi'i�i,-g,-n-i,a,",n-,imhom,ole and add a note to the plans
showing the stainless, steel straps as indicated in the standard detail.
,Zf Show Pipe size for all pipe (existing and proposed).
;§j" Label the pipe material for proposed utilities.
,41' Show grade and slope for proposed utilities.
,3)' per city standards, you will need to add a manhole to the proposed sewer main where you show a cleariout
prior to the sewer lateral for 9921 Water St.
,Of Please add a note to the new manholes that says 'connection and channelization needs to be approved by
the City of Edryionds prior to installation'.
,71" It appears tViat 9940 Water St and 1.901.8 SOUndview connects to the sewer main located on Water St.
Please show the connection of both properties to the proposed sewer main.
IX Please show a 6" cleanout at the property line.
"t" Please note that if you intend to reuse the existing laterals, approval from the City of Edmonds
must be obtained (i.e. if elevations need to be adjusted to meet city standards for slopps).
Please proviciethe invert elevation for the connection of the laterals to the proposed main line.
You will need to verity d pth'o laterals prior to approval of the Civiis. Piease .note PIans the
, 11 —e,-- f
depths of side sewers
"at property line.
Please show a wye at the connection of the sewer laterals to the proposed main line.,
Please let rne know if YOU have any questions.