Loading...
REVISED TCP 20160344.pdf01-F EVA,10 &_ I ROW PERMIT NO.: ENG 2016-00344 ISSUE DATE: PROJECT NAME: ZAyO - 10100434 -EDMONDS WAY CONTACT: Joe Morton CONTRACTOR: TBD Mailing Address: State License 4: City Business License #: Phone #: (253)-255-1917 Fax #: Email #: joseph.mortongzayo.com S�Liability Insurance Sff Bonded ADDRESS OR INTERSECTION OF CONSTRUCTION: 23221 EDMONDS WAY, EDMONDS, WA 98206 ROW WORK ASSOCIATED WITH THE FOLLOWING TYPE OF PROJECT: �Z Commercial E] Subdivision 0 City Project F] Traffic Control (Only) F Multi -Family El Single Family F-1 EUC (PUD, VERIZON, PSE, CONICAST, OVWSD): Is this permit part of a blanket permit? F-1 Other El Yes q No ANY ASSOCIATED PERMITS? BLD# ENG# DESCRIPTION OF PROPOSED WORK (Be Specific): FROM A PROPOSED MID -SHEATH SPLICE AND EXISTING STORAGE ON THE WEST SIDE OF 84TH AVE W. INSTALL FIBER CABLE USING AERIAL AND UNDERGROUND CONSTRUCTION, SOUTH ON 84TH AVE W, WEST 233RD PL SW, SOUTH ON 88TH AVE W, WEST ON 236TH ST SW AND NORTH ON EDMONDS WAY TO THE PROPOSED ZAYO EQUIPMENT LOCATION AT 23221 EDMONDS WAY. SET VAULTS ALONG THE WAY AND PULL FIBER CABLE THROUGHOUT. WAS STREET OVERLAYED WITHIN THE LAST FIVE (5) YEARS? YESE] NO Rr Year: PAVEMENT CUT: -0 Yes F-1 No CONCRETE CUT: R Yes No If yes, indicate size of cut: (2) 4x6 If yes, indicate size of cut: x RIGHT-OF-WAY AREA CLOSURE TOTAL DURATION (NUMBER OF MONTHS) 1 Sidewalk 48 Hrs + 20 LF X 5 LF 100 SF 1/2 OF 1 MONTH Alley 72 Hrs + LF X LF SF Parking 72 Hrs + LF X LF SF APPLICANT TO READ AND SIGN *Traffic control and public safety shall be in accordance with City regulations as required by the City Engineer. Every flagger must be trained as required by (WAC) 296-155-305 and must have certification verifying completion of the required training in their possession. *Restoration is to be in accordance with City codes and Standards. All street -cut trench work shall be patched with asphalt or City approved material prior to the end of the workday — NO EXCEPTIONS. Indemnity: The Applicant has signed an application which states he/she hold the City of Edmonds harmless from injuries, damages or claims of any kind or description whatsoever, foreseen or unforeseen, that may be made against the City of Edmonds or any of its departments or employees, including defense costs and attorney fees by reason of granting this permit. I have read the above statements and understand the permit requirements and acknowledge that I must follow all requirements in order for the permit to be valid. SIGNATURE ,���tib4 DATE 10/10/2016 Contractor or Agent NO WORK SHALL BEGIN PRIOR TO PERMIT ISSUANCE ADDRESS: 23221 EDMONDS WAY, EDMONDS, WA, 98206 PROJECT NAME: 10100434 - EDMONDS WAY a1,j, PLAN VIEW A / y i /1 O1 c, �. 1=3 PLAN VIEW q � IS / £ !y SITE LOCATION BILL OF MATERIALS NEW AERIAL = 1,711 FT. OVERLASH = 562 FT, NEW UNDERGROUND = 1.451 FT. EXISTING UNDERGROUND = 0 FT. RISERS = 20 FT. ISP— = 39 FT, TOTAL FOOTAGE = 3.783 FT. CONTACTS IAVO CONTACT. .TOE MORTON 22451 63RD AVE 5 98032 KENT, A 2551811 JOSEPH MORTONQZAYO COM BRYCSON GAILY MGTECHNICAL CONSULTING, INC 8521 54TH VE NE REDMOND N BRVSON980.52 BRYSONB.3DD1 �MGCTECNNICAL COM SHEETINDEX I . COVERSHEET I SITE LOCATION 2. LEGEND 3. GENERAL NOTES 4 10. PLAN VIEWSA-G 11 . ISP PIANS 2 AERIALTYPICALS 13 UN DERGROUNDTYPICALS 14. SITE PHOTOGRAPHS SCOPE OF WORK: E%ISM GRSiORAGE ON THE WESIT 5I�EO 84TH AVE f BER CARIE US NG AER ALAND UNLEHGROUND CONSTRUCT ON SOUTH ON 84TH WEST (7N 33SiN sr�wlANR ST1Il ON E�MONO. Ai E33L1 EOMONPD58WAYA" VOAULTS ALONGTHE N WAY AND—111RER CABLE THROUSHOUT. a G tiog LEGEND LINETYPES SYMBOLS INFORMATION TABLES . .. ....... AERIAL FIBER-EXISTING AERIAL FIBER ATTACH RISER EXISIING TpTRANSMISSION/DISTRIBUTION POLE ME11141INI ��� URILUPY 1111 11111-01 TABLE AERAL FIBER OVERLASH (R) RISER PROPOSED (NUMBER OF ATTACHMENTS MAY VA" STRAND EXISTING CATCH ROSIN/INLET (RECTANGULAR) TRANSMISSION POLE ,CC,C, PROPUSLum RIT -J, 0 STRAND PROPOSED CATCH BASIN/INLET (ROUND) OD DISTRIBUTION POLE N— SEQUENTIAL IN/OUT CA LUM []4�Fj CONDUIT CONDOR-EXISTING CONDUIT PROPOSED TIRE HYDRANT Ali, GROUND/BOND OU INNERDUCT EXISTING WATER/GAS VALVE INNERDUCT PROPOSED j, SEQUENTIAL IN/TAIL CALOUT GAS LIGHT POST <-) AERIAL STORAGE EXITING WATER STREET LIGHT 0, AERIAL STORAGE PROPOSED TELEPHONE E4F �AuLT SEQUENTIAL TAIL/OUT CALLOLIT FIBER OPTIC TRAFFIC LIGHT ARM ELECTRIC VAULT/BUILDING STORAGE - EXISIINO SANITARY SEWER (SEW) TREE tl VAULT/BUILDING STORAGE - PROPOSED STORM DRAIN CABLE IV STEAM CULVERT POLE ANCHOR/DOWN GUY - EXISTING HATCH PATTERNS OIL UNKNOWN UITUTY WING WALL POLE ANCHOR/DOWN GUY - PROPOSED CONCRETE 110— FENCE DOWN GUY TO EXISTING ANCHOR - PROPOSED RIGHT OF WAY BRIDGE SPLICE POINT - EXITING EDGE OF PAVEMEM STREET SIGN SPUCE POINT - PROPOSED GRASS/VEGETATLON J ABBREVIATIONS RAMP TERMINATION - EXISTING BIP ASPHALT SIDEWALK BLACK IRON PIPE UTILITY POLL - EXISTING TERMINATION - PROPOSED BSP BLACK STEEL PIPE PB PILLBOX - EXISTING CSW CONCRETE SIDEWALK UIRITY POLE - PROPOSED SWIVEL ELECT. ELECTRIC PILLBOX - PROPOSED EDP 1OTw EDGE OF PAVEMENT EDGE OF TRAVEL WAY HALT RATED VAULT - EXISTING (SIZE AND UQUIRY TYPE MAY VARY) CONSTRUCTION NOTE RESTORATION CNILOUT ---- FOG FACE OF CURB [V] �— RATE. VAULT - PROPOSED F/0 FIBER OPTIC SIZE MAY VARY) HOPE HIGH DENSITY POLYETHYLENE HANDHOLE - EXISTING LH KANDHOLE (SIZE AND UTILITY TYPE MAY VARY) NORTH ARROW JB JUNCTION BOX PAR ROLE - PROPOSED MH WHOLE (SIZE MAY VARY) MP MILE POST PEDESTAL - EXISTING O/SOFFSET (SIZE AND UTILITY TYPE MAY VARY) PH PVC POWER RISER POLY VNEL CHLORIDE ry (PS11Z1E IA—AY-VAPRIY)Ipllll RGS R RIGID GALVANIZED STEEL CONDUIT RIGHT OF WAY WET UTILITY MANHOLE -EXISTING (SIZE AND UPLITY TYPE MAY VARY) • C.11 —_4 0, 1. SEW SANITARY SEWER BORE PH - PROPOSED..1— SD STORM DRAJN (SIZE MAY VARY) SIA. STATION UTILITY POTHOLE SAM sum III TELECOMa rY'rJiv GENERAL NOTES GENERAL NOTES: AERIAL NOTES Thelocations of ulilitics shown on these drawing are only approximate. MGC TECHNICAL CONSULTING, INC. h—byd-l.-any—p.-blily 1. ALL CONSTRUCTION IS TO BE PREFORMED TO INDUSTRY ACCEPTABLE STANDARDS, o tbi�d padiea for the accuracy of thi—forrpaliod. Pe..... orking in the area covered by this drawing must contact tho--ide CaII Before-YouD,g System to a acerlaiathelocation of underground ulillliea prior I. padormipg ,y .—b— 2, ALL NEW AERIAL(AND EXISTING) CABLE HEIGHTS OF ATTACHMENTS TO BE DOCUMENTED AT THE TIME OF CONSTRUCTION, 1, ALL MATERIALS, WORKMANSHIP, AND CONSTRUCTION OF UTI LITY IMPROVEMENTS SHALL MEET OR EXCEED SITE WORK 3. 66MSTRAND TO BE USED WITH STANDARD 518`POLE LINK HARDWARE UNLESS OTHERWISE SPECIFIED BOND STRAND TO STANDARDS AND THE STANDARDS AND SPECIFICATIONS SET FORTH IN THE CITY OF EDMONDS REGULATIONS ANDAPPLICABLE STATEPOWER MAIN—HE APPLICABLE. AND FEDERAL REGULATIONS. WHERE THERE IS CONFUCT BETWEEN THESE PLANS AND THE SPECIFICATIONS, OR ANY APPLICABLE STANDARDS, THE HIGHER DUALITY STANDARD SHALL APPLY. ALL WORK WITHIN PUBLIC RO W. OR EASEMENTS MAY REQUIRE 4. ALL ANCHORS TO BE USED WILL BE 3N' SCREW TYPE INSPECTED AND APPROVED BY THE CITY OF EDMONDS INSPECTOR. INSPECTION SERVICES AND CONSTRUCTION CERTIFICATION TO BE PROVIDED BY DESIGNEE OF PROJECT SPONSORIOWNER, 5. IT IS THE CONTRACTORS RESPONSIBILITY TO MAINTAIN AND FOLLOW ALL NESC ALONG W TH APPLICABLE LOCAL 8 REGIONAL GOVERNING AUTHORITIES. ANY DISCREPANCIES BETWEEN THESE AUTHORITIES AND OR THE CONSTRUCTION PRINTS IS TO BE 2.THECONTRACTOR IS SPECIFICALLY CADNONED THAT THE LOCATION ANDIOR ELEVATION OF EXISTING UTILITIES, AS SHOWN ONVALIDATED WTH THE DESIGNER OR OWNER PRIOR TO CONSTRUCTION, THESE PLANS, IS BASED ON RECORDS OF THE VARIOUS UTILITY COMPANIES AND, WHERE POSSIBLE, MEASUREMENTS TAKEN IN THE FIELD. THE INFORMATION IS NOT TO BE REUED UPON AS BEING EXACT OR COMPLETE. THE CONTRACTOR MUST CALL THE LOCAL 6. ALL PVC OR HDPE CONDUITS ARE TO BE PLUGGEDWITH COMPRESSION STYLE PLUGS, ANY CONDUITS CONTAINING FIBER UTILITY LOCATION CENTER AT LEAST 48 HOURS BEFORE ANY EXCAVATION TO REQUEST EXACT FIELD LOCATIONS OF EXISTING CABLE REQUIRE SIMPLEX COMPRESSION PLUGS SEALING THE CONDUIT AROUND THE CABLE. UTILITIES. THE CONTRACTOR SHALL VERIFY PERTINENT LOCATIONS AND ELEVATIONS, ESPECIALLY AT THE CONNECTION POINTS AND AT POTENTIAL UTILITY CONFLICTS. IT SHALL BE THE RESPONSIBILITY OF THE CONTRACTOR TO RELOCATE ALL EXISTING UTILITIES THAT CONFLICT WITH THE PROPOSED IMPROVEMENTS SHOWN ON THESE PLANS. 3, THE CONTRACTOR SHALL BE RESPONSIBLE FOR OBTAINING ALL NECESSARY PERMITS FROM ALL APPLICABLE AGENCIES, THE CONTRACTOR SHALL NOTIFY THE CITY OF EDMONDS INSPECTOR AT LEAST 48 HOURS PRIOR TO THE START OF ANY EARTH DISTURBING ACTIVITY OR CONSTRUCTION ON ANY AND ALL PUBLIC IMPROVEMENTS IF REQUIRED. 4. THE CONTRACTOR SHALL COORDINATE AND COOPERATE WITH THE CITY OF EDMONDS AND ALL UTILITY COMPANIES NTH REGARD TO RELOCATIONS OR ADJUSTMENTS OF EXISTING UTILITIES DURING CONSTRUCTION. TO ASSURE THAT THE WORK IS ACCOMPLISHED IN A TIMELY FASHION. AND WITH A MINIMUM DISRUPTION OF SERVICE. THE CONTRACTOR SHALL BE RESPONSIBLE FOR CONTACTING ALL PARTIES AFFECTED BY ANY DSRUPTION OF ANY UTILITY SERVICE. 5, THE CONTRACTOR SHALL HAVE ONE (1) SIGNED COPY OF THE APPROVED PLANS, ONE (1) COPY OF THE APPROPRIATE STANDARDS AND SPECIFICATIONS, AND ONE (1) COPY OF ANY PERMITS AND EXTENSION AGREEMENTS NEEDED FOR THE JOB ON-SITE AT ALL TIMES, 6. THE CONTRACTOR SHALL BE RESPONSIBLE FORAM ASPECTS OF SAFETY INCLUDING, BUT NOT LIMITED TO. EXCAVATION, TRENCHING, SHORING, TRAFFIC CONTROL. AND SECURITY. ]_ IF, DURING THE CONSTRUCTION PROCESS, CONDITIONS ARE ENCOUNTERED BY THE CONTRACTOR, HIS SUBCONTRACTORS, OR OTHER AFFECTED PARTIES WHICH COULD INDICATE A SITUATION THAT IS NOT IDENTIFIED IN THE PLANS OR SPECIFICATIONS, THE CONTRACTOR SHALL CONTACT THE ENGINEER IMMEDIATELY. 8, ALL REFERENCES TO ANY PUBLISHED STANDARDS SHALL REFER TO THE LATEST REVISION OF SAID STANDARD, UNLESS SPECIFICALLY STATED OTHERW SE. 9, FOR WORK AFFECTING PUBLIC ROADWAYS OR IF REQUIRED BY THE CITY OF EDMONDS, THE CONTRACTOR SHALL SUBMIT A TRAFFIC CONTROL AND PHASING PLAN IN ACCORDANCE WITH M.0 T C D. FOR APPROVAL, PRIOR TO ANY CONSTRUCTION ACTIVITIES WITHIN OR AFFECTING THE RIGHT-OF-WAY, THE CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ANY AND ALL TRAFFIC CONTROL DEVICES AS MAYBE REQUIRED BY SAID PLANS. PRIOR TO INSTALLATION A PRECONGTRUCTION CONFERENCE SHALL BE HELD WITH CITY OF EDMONDS, 10, THE CONTRACTOR IS RESPONSIBLE FOR PROVIDING ALL LABOR AND MATERIALS NECESSARY FOR THE COMPLETION OF THE INTENDED IMPROVEMENTS SHOWN ON THESE DRAWINGS OR DESIGNATED TO BE PROVIDED, INSTALLED, CONSTRUCTED, REMOVED OR RELOCATED UNLESS SPECIFICALLY NOTED OTHERWISE. 11, PER AGENCY STANDARDS THE CONTRACTOR SHALL BE RESPONSIBLE FOR KEEPING ROADWAYS FREE AND CLEAR OF ALL CONSTRUCTION DEBRIS AND DIRT TRACKED FROM THE SITE. 12. THE CONTRACTOR SHALL BE RESPONSIBLE FOR RECORDNG RECORD INFORMATION ON A SET OF RECORD DRAWINGS KEPT AT THE CONSTRUCTION SITE AND AVAILABLE TO THE CITY OF EDMONDS INSPECTOR AT ALL TIMES. 13. DIMENSIONS FOR LAYOUT AND CONSTRUCTION ARE NOT TO BE SCALED FROM ANY DRAWING. FOR ADDITIONAL INFORMATION CONTACT THE ENGINEER FOR CLARIFICATION AND NOTE ON THE RECORD —Gs. 14. ALL EROSION AND SEDIMENT CONTROL (E S.C) MEASURES SHALL BE INSTALLED AT THE LIMITS OF CONSTRUCTION PRIOR TO GROUND DISTURBING ACTIVITY. ALL E S.C. MEASURES SHALL BE MAINTAINED IN GOOD REPAIR BY THE CONTRACTOR UNTIL SUCH TIME AS THE ENTIRE DISTURBED AREAS ARE STABILIZED WITH HARD SURFACE OR LANDSCAPING. 15. ALL WORK WITHIN THE PUBLIC RIGHT-OF-WAY IS SUBJECT TO THE JURISDICTION OF THE CITY OF EDMONDS ENGINEERING DEPARTMENT STANDARD DETAILS AND SPECIFICATIONS. 16. ALL CONSTRUCTION OPERATIONS, INCLUDING THE WARMING UP, REPAIR. ARRIVAL, DEPARTURE OR RUNNING OF TRUCKS. EARTH MOVING EQUIPMENT, CONSTRUCTION EQUIPMENT AND ANY OTHER ASSOCIATED EQUIPMENT SHALL GENERALLY BE LIMITED TO THE TIME PERIOD APPROVED BY THE CITY OF EDMONDS, Smt.. . 83RDeIT'11' I z 3 131' 134' 147 iS0 140' 15? 19'7' POLE NUMBER 2-53 n POLE NUMBER 2-264836 P D NEUTRAL. N30Y I D OLE NUMBER 2-229260 Q POERAL 0 S 383 SECONDARY !PN. 302SECONfMRY 374° SECONDARY DPoP ARY 302SL ARY DRIP 298SECONDARY DRIP 305° SE gtPSL 298 I- OEMC/Sf ORMARY SNUND S 291SL DRIP 295 COMCARE STRAND ___ 259 n XARM 258 IA70 25'10 FIR 2 h COM STRAND 242 FIR SIRWD 23'2 XiWM 22'3 IAYO OVFRUSH 2v iD° 3......_...........b1Y0 ATLACH 'MR=M-OVe CUMC.NSi ARM TO JA']" fn _._......__.__— ZAROo7TACN 242 .=. P(IIF NIIMRF� 1-54NU � I PWN MR "CE St V2RINCONDUIT MATCH TO SHEET 5 PLAN VIEW A %'� CONSTRUCTION NOTES V RESTING TV AGSIN, MORAGi PROPOSED MID SHUMET SPLICE TO EXISTING CART£ AND!PAVE I0R(1) IMF CARIE OR MATCH ESSTING CONTRACTOR TO VERIFY CORRECT INS ING USSR CARIE PRIOR TO SIMM OF CONSTRUCTION_ 0PR D OVERIASH(1) IMF—ALONG EXISTING LIWPOIPS. Q PROPOSED STWWD& LASH II) 144FUB 1—NG EISSTING UTILITY POLES O4 PROPOSED STRAND ONLY ALONG EXISTING UTILITY POI£S. 15 8�1 PLAN VIEW B CONSTRUCTION NOTES PROPOSED nw.aO au (F) 1 I uricn:oNO Ew'_ usairy s. CONSTRUCTION NOTES 5 P0.0POIPCU)4 RilEl.N.111NO C—POLE.PUIL (i) 1dd1CAEIE T.R.- HROUGH880]231 8807 231ST ST SVJ O6 PROPOS ED TRENCH (1)- CGNDDT. PULL (1) UNFCNEHL T.ROUCN. RESTORE SURFPCE PER LOCAIUR SD Cf ,� eO PR EOFFT)TTHROUGLI I/4'0 C04DU i. PULL(1)1wF C/91f. . i 9O PR ORE SURFKE PER LOCA R ON SiwNUPRoSREsi 8123231ST Sl SVJ =ED (1) 24 x35— NH. CORE VAULT AND POFCE i. COL IDC OF (1)1MF CPBIf TLROUCRL D y n = s 232ADSTSW a r 9 S'..•.,�.. 9 Sit- 88W 231ST ST SVJ 8726231ST ST SW 2 5 m 6 1 ox[xrnTw 111111111 Tov S[ vnmocn 1 9/11/18 EVKpx♦/ 1 x. Cellt. o� Wm9.. � .. - m PLAN VIEW C w'. below x. Call eara.vw&e. PLAN VIEW D CONSTRUCTION NOTES aO PROPOSED POTHOLE T /4'm CONDUIT. PULL (t11 WF C49LE RO G4. POiHO:F UiILiIES PRIOR TO BORE. 9O PtR OSEO_ ROREPIi. RESTORE $TIT—PER LOCAL O PROPOSED (t)-3fi #4ION DSHH.LORE—TPND PIKE CONDUIT. COIL tOB'OF(I)IEEF CA➢lf iHROU(31. CONSTRUCTION NOTES O9 PERDU DBOAE(2 UTILTICONOIRT. PULLIt)146FC�91E iHA0004. POiHOIE UTILIiEt PRIOR i0 BOAE. 23121 EDISOND3 WAY 23121 EDMONDS WAY �— ® 71 F' _. 232ND STSW n D O � S RE, �U 9020232ND ST SW 8926 232ND ST SW " lAl oa ex.x,rox si s,End eroas Ts enooram„s • amne o �Tn Call osa. 1 PLAN VIEW E w xax ,o,�rEo.�o..,a.aTaW,Eo.s� a.below. x Calpl(}e.ro�ywep. V PLAN VIEW F CONSTRUCTION NOTES 1. .11D TRENa (1)1 v/- DOOomi. PLn.un 1.1 ftOU- RESTORE SU—PER LOCH_ OICiION OO PROPOSED BORE (2)1-1/4'm—DURT. PUL1.(1) 144F CABLE THE— POTHOLE UELTHES PRIOR TO BORE. O PRO POSED 4'% BORE PRT, RESTORE SUR— PER tKN. )UR1501CL10N 5— ARDS. O PROPOSED (1)24'-- HHE CORE VAULT AND -CECONDUIT. COR LBO' OF 0) IN.F UeIE iHROU- CONSTRUCTION NOTES PROPOSED TRENCL (2)1 1/4 —OULILL PULL(1)144F GARY Th ROUGH. RESTORE SURFACE PER LOCAL 93M 232ND PL SW KST7 232ND PL SW JURISDICTION. '' OB PROPOSEDBORE(2)11/4'm CONDUIT, PULLf1) 144f CABLE T,'OU (R . POi)1OLE Ut Li ES ERI. TO BORE. O9 P1E PIT, RESTORE SUR— PERlMP1 RSD CF ON STAND ARDS. 9001232ND PL S W O PROPO5E0 (1) 24'x36 #4 THE CORE VAULT AND PLACE CONDO i. CO L IOU' Of (1)14F CABLE THROUGH. n S m " 232ND PL SW to o ti 23221 EDMONDS WAV oy i,J Sq 0 02 �j 8826 23'�ND PIL SW Y Y ox EmaT w.sss sNsn.. wn s.E rxOTUceaPxs e/aT/1e LavL/ 1 IS I v0 a2 wa�[u ov.V,rn wuu[xr x.er.ne'.below. M Cellena�.yau&e_ MCC IRo�LCT N L° T 2EIll to,ao4u ON05 PLAN VIEW G q " �i EIA �o1� °E — 23121 LOTIONON WAY PLAN VIEW ISP E 811 CONSTRUCTION NOTES ]O MPROPOSED TREN(2)1-1/4'0 CONDUIT, FULL (1)1MF CABtF tHD{LIGH.. AEPAR SURFACE i0 CIN OF EDMONDS STAUAR.. O ESS TING HH, CORE AND CONNECT PROPOSED 2'P CONDUIT FROM TRENCH. CGL (1) IMF CfDLE THAO WH. p POSED CORE NRSNNG HOHOU&CONNECT ED AJ2'0 CONDUU FROM TRENCH. COIL (1)144F /� HROUG , \3 FUTURE(1) 2'0 CONDUIT BY OTHERS FORTAYO. PTOP05ED'. PULL (1) IMF CABLE THROUGH, 014 PROPOSED. PLACE RAYO NETWORK EQUIPMENT &FIBER DIIHRMIBUT ON PANEL N EJBST NG F OFFMAN BOX TERNATE PROPOSED tECFCABLE. x OF STRANDS lO TERM NATETBDBYIAYO PROJECTMANAGER. tO5 FUTURERD 'OCONDUTSBYOTHEASFORIAYO.P-H) LIBER JUMPER THROUGH (1) VAUJ4T CONDUIT. TYPICAL DETAIL - A POLE ARRANGEMENT FOR AERIAL TO BURIED CABLE �_• cvr AERIAL TYPICALS TYPICAL DETAIL - B POLE ARRANGEMENT FOR REPEATER OR HANDHOLE LOCATION ca�siAamA�zR'�wu � z�x^ (x-un.am,u6 ra..er pa) m mlWm xxr. euro fza" wouz) TYPICAL DETAIL - D „sv,wrwaexrz rc ,o sm pro, TYPICAL DETAIL - E SUSPENSION STRAND - PULL AWAY FROM POLE - 5 FEET OR MORE DETAILTYPICAL JDINING D45 �1T LASHING WIRE 1T TYPICAL DETAIL - C TYPICAL CABLE h HARDWARE INSTALLATION (B.BM STRAND \ iIO-M STRAND) e.w m iw -4, 11 aw> ca[ urvw� � i/Y NxnF r �uro�iou%Y �� LLaFv 10 Baro '/a u TYPICAL DETAIL - F TYPICAL ARRANGEMENT OF MILE USHER AND CABLE GUIDE reef ,m uve cuff a x' L.- cHt[ TYPICAL DETAIL - I SUSPENSION STRAND - PULL TOWARD POLE - LESS THAN 5 FEET IASHING WIRE GRIP AND CU P r� % �`\ • ' �� X06 I TYPICAL CONCRETE PANEL CROSS SECTION DETAIL N62436 HANDHOLE DETAIL T TRENCH DETAIL FACINGEFOLIT ST'(MSOUTHSIDEOF231STSTSW f 11�1d CONSTRUCTION NOTES CAVO AE0. EL STORAGE. PROPOSED MID SULPF H sP� OF TO MST NG CABLL AND -100' (1)1"FCBFLE OR MATCN EYJSTING CONTRACFOR TO VERIFY(ORRECT MSTING FIBER CABLE PRIOR TO START OF CONSTRUCTION. 2 R1ASH (1) LMF CABLE ALONG MSTING UROPTYOFFESE ®R PROPOSEDSTRAND&CASH(1116AFCABLEALONG MUTING UTILITY PONES PROPOSEDSTRANDONLYALONGEpSi NGL)i IJTYPONES. PROPOSEDC1 S'ORSERON PBSi NG Ut UTY POLE. FULL /C\ (1) 144F CABLE THROUGH. V PROPOSED TRENCH (1) 4'O CONEFFIFF PULL (IF WE CABLE THROUGH. RESTORE SURFACE PER LOCAL NUR SD CT ON. 0T PEED TRENCH (2)1 1/4 0 CONDO , PULL (1) WE CABLETHROUG1FRESTORE SURFACE PER LCCAL IFIDIFIll- 0 PROPOSED BORE (2)1 1/4'0 CONDUIT, PULL (1) UDFCAE E fIO Gf1.POTHOLE JUIPLUES PR OR TO BORE. PROPOSED 4'%6' BORE PIT, RESTORE SURFPLE PER LOCAL. ISDICTION STANDARDS O PROPOSED (1) 2Ak34'r24' HIL. CORE --DPLACE QUIT. MOIL DO OF (1) WE CARNE THROUOI. tOi ENSTING HH, CORE AND CONNECT PROPOSED 2'0 NDUIt FROM igENCH COIL (I)144F CABLE iHRO WH. GRPOS EOCOREMSTINGIF—HOLE&CONNECT POSED 2'0 CONDUIT FROM TRENCH COILH)144F PUTHIOUCN, 13 FLITURE(1) 2'c CONDUIT BY OTHERS FOR ZAY0 PROPOSED: PUFFF) L", CABLE THROUGH. O PR POSED PLACE ]AVO NEMro0.K EgUIPMENi IF HEIR DISTRIBUTION PANEL IN OPSTING HO D,MN BOK TERMINATE PROPOSED -F CABLC — STRANDS TO TERMINATE TBD BY—O PROJECT MANAGER. OUR(2)2" CONDUITS BY OTHERS FOR 2LYO. PULL 0) FIBER JUM PER THROLIG4 (1) VACANT CONDUIl cd de Chapter 4 J W IZ U' Z O Z O W U wO w z Z0 Z 2 w U U Q W lL W O ❑w a W M y 0 QLU 4t:: Z xLIJ m O Za Q Z ❑ W I- < _ >a o 7 UO Y > Q 5 U o Q O w 0 LLO ❑ w aa LL, J m O m Mobile Operations O z W J �C TCP 25 — Typical Mobile Lane Closure Operation on a Two -Lane Roadway Z O LU �a EL W O W Q N JJ d m z U U F- egg J U a w U_ LU S z z z w U Z Q WSDOT Work Zone Traffic Control Guidelines for Maintenance Operations M54-44.05 Page 4-5 December 2014 OZLL W W V U_ W d. a �Z w W VS 2(F] -' Oju YH > N H J W IZ U' Z O Z O W U wO w z Z0 Z 2 w U U Q W lL W O ❑w a W M y 0 QLU 4t:: Z xLIJ m O Za Q Z ❑ W I- < _ >a o 7 UO Y > Q 5 U o Q O w 0 LLO ❑ w aa LL, J m O m Mobile Operations O z W J �C TCP 25 — Typical Mobile Lane Closure Operation on a Two -Lane Roadway Z O LU �a EL W O W Q N JJ d m z U U F- egg J U a w U_ LU S z z z w U Z Q WSDOT Work Zone Traffic Control Guidelines for Maintenance Operations M54-44.05 Page 4-5 December 2014 Mobile Operations 11-1 &M I Z ) VWI )L \LL 3 Eo z Wo W /§c if;N Sgm k §�k0 k §§§ c W(� _j 3 )k§ �`ZF ( oz< L \(( LU WE L > k)se § LLI [3) _ C, z § k§» 2 I+% a _j 0� ( i I * § z § ) 0 Chapter 4 § ) 30m _ Uj !) k\} rn f§ 2U)' $§ %g W3 \ k) 02 §§ )� /} � �\ % e j LL P»u LL / / a. <o )$ \�Gm B� �� W( 2\Bw o= Z) _J 0D A/= ^ )D %o §%in- 11-1 &M I Z ) VWI )L \LL 3 Eo z Wo W /§c if;N Sgm k §�k0 k §§§ c W(� _j 3 )k§ �`ZF ( oz< L \(( LU WE L > k)se § LLI [3) _ C, z § k§» 2 I+% a _j 0� ( i I * § z § ) 0 Chapter 4 § ) Uj !) f§ )/ %g )EL \ k) §§ )� /} 2[ % e j LL P»u LL / / a. <o )$ \�Gm B� e�E§ W( 2\Bw o= Z) _J 0D A/= ^ )D A / }o \ \ Uj ( ± (L_ F \ \§ ( § @z ; o k° E z W \\ / \ ■ LLI TCP 26 — Typical Momm Shoulder Closure Operation on a Two -Lane Roadway Page a■ ws oT Work zn Traffic Con d Guidelines erMaintenance oetn M54-44.05 December 20 k Chapter 2 Stationary Work Zones p N `fix W Q w a s zWi w 54 0 a ® SW�d o � aw F � L _O y'O m `on> o c- E ° y 0 LL.5 N N,a O myEy c - TL m Eyy m.' M ~ N p f0 e > Q � p L E U n W N O 'O Q O o g m E L N N iY c 3 0 W m �L. Iwi z C m W C7 W z Z m o P W y 0 U Q U ~ 0 0=Cr U�, O IS a *? N L o U O NuJJ 7 F Q' N C C/) W LL u a E2W w w 5 Q pp pp C N N LL M m j W � m Y n N 9 V z Z Z p 2 x N J x U, Ana n o N O 11 X g N U 0 f0 f2 y N W N 0 G O J Z U N U Q Qa2 ¢ y U) Z 5 c°s Z a d y x LL1 m = r y f Q z w Ir K K Z �y N Z Q $ N� � N LL K K OC c K D Q❑ Stationary Work Zones p N `fix W Q w a s zWi w 54 0 a ® SW�d o � aw F � L _O y'O m `on> o c- E ° y 0 LL.5 N N,a O myEy c - TL m Eyy m.' M ~ N p f0 e > Q � p L E U n W N O 'O Q O o g m E L N N iY c 3 0 W m �L. Iwi z C m W C7 W z Z m o P o n U Q U ~ 0 0=Cr EL IS a *? N L o U O` C U y 7 F Q' N C C/) W LL Q O E2W w w 5 Q pp pp C N N LL M m N X w ❑ J Q n CO 'SOp z Z Z p m o N J x U, Ana n o {_- Ei v 3 $? y m a Z X f0 f2 y N W N 0 G O J a m � v - w U O ac3 d> w c3 N o0 Stationary Work Zones p N `fix W Q w a s zWi w 54 0 a ® SW�d � ZF W 28 N U w a� og °° w �Cdp Q I aw F � L _O y'O m `on> o c- E ° y 0 LL.5 N N,a O myEy c - TL m Eyy m.' M ~ N p f0 e > Q � p L E U n W N O 'O Q O o g m E L N N iY c 3 �L. =O C 0 0=Cr IS Z5N *? N L o U O` C U y 7 F Q' N C E2W m v— '2 X I -u,2 a CO 'SOp 7 Qa�� �' a c y N N > m od �L L E i y y Ei v 3 $? y m X f0 f2 y N W N 0 G O ac3 d> w c3 N o0 Nd O Z 5 c°s x J IM 12 13 m p o F c 2 m _ � e ® N E W m ❑ Q Uj d' N d � a ® W LL J m W 9 ❑ O U W W V WIN ® >- �_ r C7 x J ~ a Q (n N W" W Z ®®® LL W Q aim 1 I Q 2 K Q Q Q O 0 U a a ® IZ N I- J TCP 3 Typical Single -Lane Closure for Multi -Lane Roadways } WSDOT Work Zone Traffic Control Guidelines for Maintenance Operations M54-44.05 Page 2-5 December 2014