Revision 4 Detail Letter.pdfStud ICMENG STRAZZARA AR PTr CTURC CLA NNL�G C C1 Neil September 20th, 2018 The City of Edmonds Building & Planning Dept. 121 5th Avenue North Edmonds, WA 98020-3145 Subject: Post Permit Revision Plan Check Review Permit: 2016-1538 On behalf of Studio Meng Strazzara (architect) for Westgate Village Mixed -Use Building, you will find a list of post permit revisions in itemized format and supplemental drawings for both planning and building divisions. Level P1: Water Heater Room This room, P347 and correspondingly numbered T-0" x T — 0" hollow metal door, has been added to the northwest corner of the P1 garage during design build. It is a half -height CMU wall with metal framing on top. Maintenance Room This room, P346 and correspondingly numbered T-0" x T — 0" hollow metal door, has been added to the northeast corner of the P1 garage during design build. It is a half -height CMU wall with metal framing on top. Stairs The podium level stairs are to be combustible and within a 3hr rated enclosure with 3hr rated doors at the Type IA podium levels per previous city discussion. See attached letter. Level 1: Concrete Wall & Metal Gate Door An infill concrete wall was added to refine the patterning of solid and void space at the east end of the building. The concrete wall matches the other exterior walls in the use of architectural reveal patterning and concrete reveal plugs. A black welded wire and tube steel mesh door and adjacent fence panel are added for building security and egress. Panic hardware is located on the garage side. The mesh allows visibility through. Storefront S6 at Lobby The glazing at the east side of the lobby has been made to match the west side, providing classic symmetry and increased glazing via the S6 storefront type. The lower piece sets atop an 1,40.EVIS1101V �Ei �30LDIIVG DEPARTMENT C - iy COPY CITY OF EDMONDS architectural stem wall, and the lower and upper transom piece are full vision glazing, allowing light and transparency between interior and exterior spaces. Stairs The podium level stairs are to be combustible and within a 3hr rated enclosure with 3hr rated doors at the Type IA podium levels per previous city discussion. See attached letter. Levels 2-4: MUA shaft MUA-1 shaft was relocated to the telecom Rm #1. Shaft to be a 1-hour fire -resistance rated assembly tested in accordance with ASTM E 119 or UL 263 per IBC 713.4, with a 1-hour fire -resistance rated access door per IBC Table 716.5, and fire and smoke damper access per IBC 717.4. Level Roof: RTU/MUAs RTU/MUAs were shifted slightly at the roof level to better work with the building plan and roof configuration. See separate MEP permit. MUA-1 now aligns with new shaft location below. General Sheets: Energy G015, G016 The energy calculations were updated per a new energy consultant for increased accuracy for the Westgate project. Assemblies Sheet G003 The assemblies sheet reflects adjustments made during the energy recalculation to support the design intent and energy code. If you have any questions please contact myself or Chris Davidson. Best Regards, 0'&":�- ?. Alexandra Ziemba studio MENG STRAZZARF 2001 Western Ave, STE 200 1 Seattle WA 98121-2114 206.587.3797 www.studioms.com From: Miller, Chuck <Chuck.Miller@edmondswa.Rov> Sent: Monday, May 21, 2018 10:54 AM To: Chris Davidson <CDavidson(a)studioms.com> Subject: RE: Westgate Edmonds: Wood framed stairs in 1A While not explicitly allowed/prohibited in the 2015 IBC, it is permissible to frame the interior exit stairs in the IA portion below the 'podium line' of wood, just as of that in the VA portion. During the 2021 113C: code hearings, a specific allowance in 1Bl )I U.2 was proposed to avow wood stair construction and was unanimously approved. It still has to go through the public comment hearing this fall. At the same time, the proposal was also submitted to the Washington State Building Code Council as an amendment to that section in the 2018 IBC. The approach has been utilized for many projects in Bellevue under a policy developed by their Building Official, The portion of the stairway in the IA portion below the `podium line' must be enclosed by 3-hour fire - resistance rated construction with opening protectives in accordance with IBC 716. The VA portion of the interior exit stairway above the 'podium line' must be enclosed by 2-hour fire -resistance rated construction with opening protectives in accordance with IBC 716. My apologies for the delayed response. Chuck Miller, Senior Plans Examiner chuck.mil ler(u,ednxxiclswa.gov 425-771-0220 nc. 10,11 Development Services Department Building Division 121 5"' Avenue N Edmonds, WA 98020 www.ednumdswa.vov Development Services Permit Center Hours Monday & Tuesday -- 8:OOAM — 4:30PM Wednesday — 8:30AM — 12:OOPM Thursday & Friday — 8:OOAM — 4:30PM