Loading...
ROW PERMIT APPLICATION RECD 11-26-18.pdf0 \:L L?,11(7. -,NC. 1 s`) u ROW PERMIT NO.: ENG ISSUE DATE: RIGHT-OF-WAY CONSTRUCTION PERMIT APPLICATION PROJECT NAME: The Village at Westgate CONTRACTOR: Snohomish County PUD Mailing Address: PO Box 1107, Everett, WA 98206 State License #: City Business License #: CONTACT: David Cerdenola Phone #: 425-783-5107 Fax #: Email #: dccerdenola@snopud.com ❑ Liability Insurance ❑ Bonded ADDRESS OR INTERSECTION OF CONSTRUCTION: 10032 Edmonds Way, Edmonds ROW WORK ASSOCIATED WITH THE FOLLOWING TYPE OF PROJECT: ❑■ Commercial ❑ Subdivision ❑ City Project ❑ Traffic Control (Only) ❑ Multi -Family ❑ Single Family ❑■ EUC (PUD, VERIZON, PSE, COMCAST, OVWSD): Is this permit part of a blanket permit? ANY ASSOCIATED PERMITS? ❑ Other ❑ Yes A No BLD# ENG# DESCRIPTION OF PROPOSED WORK (Be Specific) • PUD to relocate two (2) existing power poles. Power poles are currently set in conflict with new Westgate Village sidewalk. Relocate poles in new planter strip between road and new sidewalk, approximately 24" behind curb. WAS STREET OVERLAYED WITHIN THE LAST FIVE 5 YEARS? YES ❑ NO ■❑ Year: PAVEMENT CUT: ❑ Yes 0 No If yes, indicate size of cut: x CONCRETE CUT: ❑ Yes A No If yes, indicate size of cut: X. RIGHT-OF-WAY CLOSURE AREA TOTAL DURATION (NUMBER OF MONTHS) Sidewalk 48 Hrs + LF X LF SF Alley 72 Hrs + LF X LF SF Parking 72 Hrs + LF X LF SF APPLICANT TO READ AND SIGN *Traffic control and public safety shall be in accordance with City regulations as required by the City Engineer. Every flagger must be trained as required by (WAC) 296-155-305 and must have certification verifying completion of the required training in their possession. *Restoration is to be in accordance with City codes and Standards. All street -cut trench work shall be patched with asphalt or City approved material prior to the end of the workday — NO EXCEPTIONS. Indemnity: The Applicant has signed an application which states he/she hold the City of Edmonds harmless from injuries, damages or claims of any kind or description whatsoever, foreseen or unforeseen, that may be made against the City of Edmonds or any of its departments or employees, including defense costs and attorney fees by reason of granting this permit. I have read the above statements and understand the permit requirements and acknowledge that I must follow all requirements in order for the permit to be valid. SIGNATURE DATE 11 / 16/ 18 Contractor or Agent NO WORK SHALL BEGIN PRIOR TO PERMIT ISSUANCE LEGEND: NOTE: ❑o CONE OR CHANNELIZING DEVICE (SEE STD 7-13) J SNOHOMISH COUNTY EP10= PUBLIC UTILITY DISTRICT NO 1 CURB lool W 0 WORK AREA ❑o I 1. RETROREFLECTORIZED SIGNS AND FLASHING BEACON SHALL BE INSTALLED AT EACH SIGN FOR NIGHT-TIME USE. 2. DISTANCES MAY VARY AS APPROVED BY THE ENGINEER. 3. FLAGGERS WITH FULL FLAGGING SEQUENCE REQUIRED TO CONTROL TRAFFIC WHENEVER THE CONTRACTOR MUST INTERRUPT TRAFFIC FLOW TO ACCESS THE WORK SITE WITH MATERIALS OR EQUIPMENT. TABLE A TRUCK WITH FLASHING OR BEACON T TAPER LENGTH (TABLE A) SPEED TAPER LENGTH (FT) CONE SPACING (FT) (MPH) OFFSET WIDTH TAPER TANGENT 10, 12' 25 105 125 20 25 30 150 180 20 30 35 205 245 20 35 40 270 320 20 40 45 450 540 20 45 WITH \ 30" NO PERSON SHALL STOP OR DIRECT VEHICLE TRAFFIC, EVEN MOMENTARILY, UNLESS THAT PERSON IS A CERTIFIED FLAGGER AND A FULL FLAGGING SEQUENCE IS PROVIDED ON EACH FLAGGED APPROACH AS REQUIRED BY WAC 296-155-305. THIS CONSISTS OF A 3 SIGN SEQUENCE ON ALL APPROACHES WITH SPEEDS OF 40 MPH OR LESS AND A 4 SIGN SEQUENCE ON ALL APPROACHES WITH SPEEDS 45 MPH OR GREATER. 350 (W4.2 R) 350' 30" RIGHT LANE CL�(W A 20-5R) 350' 30" ROAD ONSTRUCTION AHEAD (W 20-1) 30" TRAFFIC CONTROL PLAN PRn,IFnT RELOCATE (2) PUD POLES LOCATION 10032 EDMONDS WAY, EDMONDS ENGINEER DAVID CERENOLA DATE PHONE 425-783-5107 11/16/18 ORDER 100023265 CELLULAR SNOHOMISH COUNTY EPUM PUBLIC UTILITY DISTRICT NO 1 \ s� PRIMARY POLE NOTES OA POLE PLI # 205964 SET 50' CL 1 POLE (PW1050, N0110), 4' LOC POLE FACE 2'BACK OF CU FRAME (12F303) 30 TAN ASSY INSTL 3/8'' PRI SIDEWALK GUY (GO107 & (1) AHR, L= 10' (SW) RMV 37 KVA OH XEMR UTC # HANG 37 KVA OH XEMR (12F601, BA21F XFR OH SVCS XFR AND SPLICE (IF NECCESSARY) 336 AAC PRI AND 3/0 NEUT XFR STLT# 122856-H STRIP, TOP & ABANDON 45' POLE TO COMMUNICATIONS OB POLE PLI # 2210 SET 50' CL 1 POLE (PW1050, N0110) 3' NW LOC POLE FACE 2'BACK OF CURB FRAME (12F303) 30 TAN ASSY INSTL 3#8'' PRI SIDEWALK GUY (GO107) & (1) AHR, L= 8' (SW) FRAME (12U308, T1013) UG TERM 30 1/0 ASSY, FU 100 T SEE UG DWG # 11026 XFR AND SPLICE (IF NECCESSARY) 336 AAC PRI AND 3/0 NEUT XFR OH SVCS XFR STLT# 112087-H STRIP, TOP & ABANDON 45' POLE TO COMMUNICATIONS © POLE PLI # 159792 EXIST 45' POLE i l. LOCATION 10032 EDMONDS WAY, EDMONDS, WA 98020 POLE NO PLI 205964, 2210 NW I/4S 36 T 27 R 03 REASON FOR WORK RELOCATE (2) POLES FOR WESTGATE VIL_L_AGE DATE WORK COMPLETED FOREMAN SUBSTATION WESTGATE CIRCUIT NO 12-405 PHASE 123 ENGINEER DAVID CERDENOLA PHONE 425-783-5107 CELLULAR 425-308-2927 NORTH PLAN VIEW SCALE: V=30' FEES REQ'D AREA LYNNWOOD DATE 10/23/18 ORDER 100023265 ENGINEER CERDENOLA OPERATION 0060 DRAFTER UGND NO 11026 APPROVED SCALE AS NOTED DATE ENG AS -BUILT VERIFICATION PRINTED ❑ PHASING, TAPS & FUSING PRIMARY OVERHEAD ❑ RESIDENTIAL ❑ COMMERCIAL LEO# ❑ POLE & VAULT STENCILS ❑ CABLE TAGS ❑ YES ❑ NO ❑ FRAMING ❑ EQUIPMENT LOCATION La $ _ 8 PRIMARY UNDERGROUND ❑ RESIDENTIAL ❑ COMMERCIAL BASIC FEE $ LEU# $ /'= $ SECONDARY UNDERGROUND BASIC FEE $ UNDERGROUND PLAT BASIC FEE $ ENGINEERING tFT@$ =$ PLAT CONSTRUCTION tFT@$ =$ STREET LIGHTING tFT@$ =$ CROSSINGS CFT@$ = $ WORK IN RIGHT OF WAY ❑ PRIMARY ❑ SECONADARY (tFT@$ _ $ MISCELLANEOUS FEES VAULT $ PERMIT $ $ $ TOTAL DUE $ DATE PAID RECEIPT# NEW SVCE APPLICATION# mKmw' 111 VERIFIED BY DATE NESC VIOLATIONS ❑ NO ❑ YES (SEE NOTES) PERMITS (DATE GRANTED) ❑ TREE TRIM ❑ STATE ❑ COUNTY ❑ EDMONDS EASEMENTS ❑ REQUIRED E# ❑ NOT REQUIRED DATE SENT TO R/W DATE APPROVED FOREIGN CONTACTS ❑ JPN# ❑ JOINT TRENCH FRONTIER & CATV ❑ JOINT BORE FRONTIER & CATV POLE STENCILING FROM TO TAKE OFF POLE PRE-CONSTR REQUIREMENTS ❑ TREE TRIM ❑ PUD LOCATOR ❑ BACKHOE ❑ ❑ ONE CALL DATE No. STREET LIGHTING ❑ YES ❑ NO M&R AS -BUILT GIS GIS QC M&R GIS Ph JOINT USE LOCATION MAP PAGE 474-G1 VICINITY MAP EXISTING POLE EXISTING POLE -TO BE REMOVED NEW POLE NEW POLE TO REPLACE EXISTING POLE EXISTING DISTRIBUTION LINE - - - - - - - - - NEW DISTRIBUTION LINE EXISTING TRANSMISSION LINE NEW TRANSMISSION LINE aim &*]=Ko] lI1L1:ymael►11LermIto] a RIGHT-OF-WAY LINE PROPERTY LINE LINE TO BE REMOVED U 0 w w LL J N U 00 0 6 0 U c 0 0 U� -N W QO Elo `7 cn oQ �. 0-) r0 ww l< �Q �o