Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
ROW Permit Rec'd 4.11.19.pdf
of EVA4(.) .1/vC. is y4 ROW PERMIT NO.: ENG. ISSUE DATE: RIGHT-OF-WAY CONSTRUCTION PERMIT APPLICATION PROJECT NAME: Edmonds Pole Transfers CONTACT: Justin Fisler CONTRACTOR: Wave Division Holdings LLC Phone #: Mailing Address: 401 Parkplace Center, Ste #103 Fax #: State License #: WAVEDHL874CD Email #: [� Liability Insurance ❑ Bonded City Business License #: N R-024945 ADDRESS OR INTERSECTION OF CONSTRUCTION: 425-457-2306 ROW WORK ASSOCIATED WITH THE FOLLOWING TYPE OF PROJECT: ❑ Commercial ❑ Subdivision ❑ City Project ❑ Traffic Control (Only) ❑ Multi -Family ❑ Single Family ❑ EUC (PUD, VERIZON, PSE, COMCAST, OVWSD): Is this permit part of a blanket permit? ANY ASSOCIATED PERMITS? ❑ Other © Yes ❑ No BLD# ENG# DESCRIPTION OF PROPOSED WORK (Be Specific): Wave to perform pole transfers at various locations with in the City of Edmonds. Wave is Next -To -Go (NTG) on all poles. WAS STREET OVERLAYED WITHIN THE LAST FIVE 5 YEARS? YES 0 NO Year: PAVEMENT CUT: ❑ Yes ❑ No If yes, indicate size of cut: x CONCRETE CUT: ❑ Yes ❑ No If yes, indicate size of cut: x RIGHT-OF-WAY AREA CLOSURE TOTAL DURATION (NUMBER OF MONTHS) Sidewalk 48 Hrs + LF X LF SF Alley 72 Hrs + LF X JLF SF Parking 72 Hrs + LF X SF APPLICANT TO READ AND SIGN *Traffic control and public safety shall be in accordance with City regulations as required by the City Engineer. Every flagger must be trained as required by (WAC) 296-155-305 and must have certification verifying completion of the required training in their possession. *Restoration is to be in accordance with City codes and Standards. All street -cut trench work shall be patched with asphalt or City approved material prior to the end of the workday — NO EXCEPTIONS. Indemnity: The Applicant has signed an application which states he/she hold the City of Edmonds harmless from injuries, damages or claims of any kind or description whatsoever, foreseen or unforeseen, that may be made against the City of Edmonds or any of its departments or employees, including defense costs and attorney fees by reason of granting this permit I have read the above statements and understand the permit requirements and acknowledge that I must follow all requirements in order for the permit to be valid. Justin Fisler �edm�g: uco�. SIGNATURE DATE Contractor or Agent NO WORK SHALL BEGIN PRIOR TO PERMIT ISSUANCE www.invarion.com ADDRESS: VARIOUS LOCATIONS, EDMONDS - PROJECT NAME: WAVE DIVISION HOLDINGS POLE TRANSFERS T< n4AAPCEWOOD HOLLS t 203rd St SW Daley St 204th St SW PROJECT LOCATIONS 524 Pate 206th St SW 206th ptrd '_` + n � Y Ridge \j [�.lj S Park l4lairt st :� zoeth 5t SW Dayton St Yost Pork Q Seattle t' Heights Walnut St n••• ko r $ � Pik c 5 t M ch 216th St SW 216th St SW an j a a41 $ c F r E �' Q CU Edmo+tds Hospital Q ® u F ',220th St SW a � MELODY HILL`^ 2Zoth St SV. `^ c � 222nd St SN! 224th St SW ?ash St 511J 224th St r 3 22Gth St SW Q' ESPERANCE 226th PI SW c 226th St SW 228th St SVti' R]WN CENTER 3; _ r CL lu y F LDU n 4 Wachusett Rd as = ¢ CLINGER Q rr- 23bth $t SW 2361h St SW J l Woodv►a Restlown F a�0 2 Nile Golf & J d v c+9`� Lake Bollinger Cowi:ry Club GA7` q ' --- ---- -------.-. 244this'`SW------------N:205thSt- _'-_---------:Tp{+J:205th,Si i1[.'OihSt--- --------- R a Aurora N Lf qu FIBER DESIGN & CONSTRUCTION LOCATION: Edmonds PERMIT TECH: JF PROJECT NUMBER: DATE: 11-21-2018 CONFIDENTIAUPROPRIETARTY SHEET 1 OF 12 CONTACTS: JUSTIN FISLER WAVE-FDC 401 PARKPLACE CENTER KIRKLAND, W.A. 98033 425-457-2306 JFISLER@ WAVEBROADBAND.COM SHEET INDEX: SHEET I - OVERVIEW SHEET 2 - NOTES SHEET 3 - SITEVIEW SHEET 4 - SITEVIEW #2 SHEET 5 - SITEVIEW #3 SHEET 6 - SITEVIEW #4 SHEET 7 - SITEVIEW #5 SHEET 8 - SITEVIEW #6 SHEET 9 - SITEVIEW #7 SHEET 10 - SITEVIEW #8 SHEET 11 - SITEVIEW #9 SHEET 12 - SITEVIEW #10 SCOPE OF WORK: WAVE TO PERFORM POLE TRANSFERS IN THE CITE OF EDMONDS. WAVE STEPS ARE NEXT -TO -GO, (NTG), WAVE TO ADD (2) NEW ANCHORS TO PUD POLES. www.invarion.com GENERAL NOTES 1. ALL MATERIALS, WORKMANSHIP AND CONSTRUCTION OF UTILITY IMPROVEMENTS SHALL MEET OR EXCEED SITE WORK STANDARDS AND THE STANDARDS AND SPECIFICATIONS SET FOURTH IN THE CITY OF EDMONDS REGULATIONS AND APPLICABLE STATE AND FEDERAL REGULATIONS. WHERE THERE IS CONFLICT BETWEEN THESE PLANS AND THE SPECIFICATIONS, OR ANY APPLICABLE STANDARDS, THE HIGHER QUALITY STANDARD SHALL APPLY. ALL WORK WITH PUBLIC R.O.W. OR EASEMENTS MAY REQUIRE INSPECTED AND APPROVED BY THE CITY OF EDMONDS INSPECTOR. INSPECTION SERVICES AND CONSTRUCTION CERTIFICATION TO BE PROVIDED BY THE DESIGNEE OF THE PROJECT SPONSOR/OWNER. 2. WAVE/CONTRACTORS ARE SPECIFICALLY CAUTIONED THAT THE LOCATION AND/OR ELEVATION OF THE EXISTING UTILITIES, AS SHOWN ON THESE PLANS, IS BASED ON RECORDS OF THE VARIOUS UTILITY COMPANIES AND, WHERE POSSIBLE, MEASUREMENTS TAKEN IN THE FIELD. THE INFORMATION IS NOT TO BE RELIED UPON AS BEING EXACT OR COMPLETE. WAVE/CONTRACTORS MUST CALL THE LOCAL UTILITY LOCATION CENTER AT LEAST 48 HOURS BEFORE ANY EXCAVATION TO REQUEST EXACT FIELD LOCATIONS OF EXISTING UTILITIES. WAVE/CONTRACTOR SHALL VERIFY PERTINENT LOCATIONS AND ELEVATIONS, ESPECIALLY AT THE CONNECTION POINTS AND AT POTENTIAL UTILITY CONFLICTS. IT SHALL BE THE RESPONSIBILITY OF WAVE/CONTRACTOR TO RELOCATE ALL EXISTING UTILITIES THAT CONFLICT WITH THE PROPOSED IMPROVEMENTS SHOWN ON THESE PLANS. 3. WAVE/CONTRACTORS SHALL BE RESPONSIBLE FOR OBTAINING ALL NECESSARY PERMITS FROM ALL APPLICABLE AGENCIES. WAVE/CONTRACTOR SHALL NOTIFY THE CITY OF EDMONDS INSPECTOR AT LEAST 48 HOURS PRIOR TO THE START OF ANY EARTH\DISTURBING ACTIVITY OR CONSTRUCTION ON ANY AND ALL PUBLIC IMPROVEMENTS IF REQUIRED. 4. WAVE/CONTRACTOR SHALL COORDINATE AND COOPERATE WITH THE CITY OF EDMONDS AND ALL UTILITY COMPANIES WITH REGARD TO RELOCATIONS OR ADJUSTMENTS PF EXISTING UTILITIES DURING CONSTRUCTION, TO ASSURE THAT THE WORK IS ACCOMPLISHED IN A TIMELY MANNER, AND WITH A MINIMUM DISRUPTION OF SERVICE. WAVE/CONTRACTOR SHALL BE RESPONSIBLE FOR CONTACTING ALL PARTIES AFFECTED BY ANY DISRUPTION OF ANY UTILITY SERVICE. 5. WAVE/CONTRACTOR SHALL HAVE ONE (1) SIGNED COPY OF THE APPROVED PLANS, ONE (1) COPY OF THE APPROPRIATE STANDARDSAND SPECIFICATIONS, AND ONE (1) COPY OF ANY PERMITS AND EXTENSION AGREEMENTS NEEDED FIR THE JOB ON SITE AT ALL TIMES. 6. WAVE/CONTRACTOR SHALL BE RESPONSIBLE FOR ALL ASPECTS OF SAFETY INCLUDING, BUT NOT LIMITED TO: EXCAVATION, TRENCHING, SHORING, TRAFFIC CONTROL, AND SECURITY. 7. IF DURING THE CONSTRUCTION PROCESS, CONDITIONS ARE ENCOUNTERED BY WAVE, THE CONTRACTORS, OR SUBCONTRACTORS, OR OTHER AFFECTED PARTIES WHICH COULD INDICATE SITUATION THAT IS NOT IDENTIFIED IN THE PLANS FOR SPECIFICATIONS, WAVE/ CONTRACTOR SHALL CONTACT THE PERMITTEE. 8. ALL REFERENCES TO ANY PUBLISHED STANDARDS SHALL REFER TO THE LATEST REVISION OF SAID STANDARD, UNLESS SPECIFICALLY STATED OTHERWISE. 10. WAVE/CONTRACTOR ARE RESPONSIBLE FOR PROVIDING ALL LABOR AND MATERIALS NECESSARY FOR THE COMPLETION OF THE INTENDED IMPROVEMENTS SHOWN ON THESE DRAWINGS OR DESIGNED TO BE PROVIDED, INSTALLED, CONSTRUCTED, REMOVED OR RELOCATED UNLESS SPECIFICALLY NOTED OTHERWISE. 11. PER AGENCY STANDARDS WAVE/CONTRACTOR SHALL BE RESPONSIBLE FOR KEEPING ROADWAYS FREE AND CLEAR OF ALL CONSTRUCTION DEBRIS AND DIRT TRACKED FROM THE SITE. 12. WAVE/CONTRACTOR SHALL BE RESPONSIBLE FOR RECORDING INFORMATION ON A SET OF RECORD DRAWINGS KEPT AT THE CONSTRUCTION SITE AND AVAILABLE TO THE CITY OF EDMONDS INSPECTOR AT ALL TIMES. 13. DIMENSIONS FOR LAYOUT AND CONSTRUCTION ARE NOT TO BE SCALED FROM ANY DRAWING. FOR ADDITIONAL INFORMATION CONTACT THE PERMITTEE FOR CLARIFICATION AND NOT ON THE RECORD DRAWINGS. 14. ALL EROSION AND SEDIMENT CONTROL MEASURES SHALL BE INSTALLED AT THE LIMITS OF CONSTRUCTION PRIOR TO GROUND DISTURBING ACTIVITY. ALL E.S.C. MEASURES SHALL BE MAINTAINED IN GOOD REPAIR BY WAVE/CONTRACTOR UNTIL SUCH TIME AS THE ENTIRE DISTURBED AREAS ARE STABILIZED WITH HARD SURFACE OR LANDSCAPING. 15. ALL WORK WITHIN THE PUBLIC R.O.W. IS SUBJECT TO THE JURISDICTION OF THE CITY OF EDMONDS ENGINEERING DEPARTMENT STANDARD DETAILS AND SPECIFICATIONS. 16. ALL CONSTRUCTION OPERATIONS, INCLUDING THE WARMING UP, REPAIR, ARRIVAL, DEPARTURE OR RUNNING OF TRUCKS, EARTH MOVING EQUIPMENT, CONSTRUCTION EQUIPMENT AND ANY OTHER ASSOCIATED EQUIPMENT SHALL GENERALLY BE LIMITED TO THE TIME PERIOD APPROVED BY CITY OF EDMONDS. Know whars below. Call before you dig. 9. FOR WORK AFFECTING PUBLIC ROADWAYS OR IF REQUIRED BY CITY OF EDMONDS, WAVE/ CONTRACTOR SHALL SUBMIT A TRAFFIC CONTROL AND PHASING PLAN IN ACCORDANCE WITH N M.U.T.C.D. FOR APPROVAL. PRIOR TO ANY CONSTRUCTION ACTIVITIES WITHIN OR AFFECTING THE R.O.W. WAVE/CONTRACTOR SHALL BE RESPONSIBLE FOR PROVIDING ANY AND ALL TRAFFIC CONTROL DEVICES AS MAY BE REQUIRED BY SAID PLANS. PRIOR TO INSTALLATION A PRECONSTRUCTION CONFERENCE SHALL BEHELD WITH THE CITY OF EDMONDS. — www.invarion.com ciL)e FIBER DESIGN & CONSTRUCTION CONTACTS: Justin Fisler CONSTRUCTION MANAGER: JUSTIN FISLER WAVE-FDC 425.457.2306 JFISLER@WAVEBROADBAND.COM 1 PERMIT TECH: JUSTIN FISLER WAVE-FDC 425.457.2306 JFISLER@WAVEBROADBAND.COM SITE ADDRESS: 7TH AVE S LEGEND: Approx Right of Way - - - Approx Center Line Survey Monument Existing Aerial Over Lash New Strand New Fiber Existing Wave Underground Existing Customer Conduit New Wave Conduit New Wave Anchor O Existing Wave Vault 0 New Wave Vault ® Customer Vault Bore Pit 0 Distribution Poles Q Transmission Poles 10 New Wave Pole (>4 New Aerial Storage LOCATION: Edmonds PERMIT TECH: JF PROJECT NUMBER: 100018397 CON FIDENTIAL/PROPRIETARTY SHEET 4 OF 12 www.invarion.com ciL)e FIBER DESIGN & CONSTRUCTION CONTACTS: Justin Fisler CONSTRUCTION MANAGER: JUSTIN FISLER WAVE-FDC 425AS7.2306 JFISLER@WAVEBROADBAND.COM PERMIT TECH: JUSTIN FISLER WAVE-FDC 425.457.2306 JFISLER@WAVEBROADBAND.COM SITE ADDRESS: 7TH AVE S LEGEND: Approx Right of Way - - — Approx Center Line Survey Monument Existing Aerial Over Lash New Strand New Fiber Existing Wave Underground Existing Customer Conduit New Wave Conduit New Wave Anchor p Existing Wave Vault O New Wave Vault C� Customer Vault ® Bore Pit O Distribution Poles 0 Transmission Poles N i New Wave Pole D-0 New Aerial Storage LOCATION: Edmonds PERMIT TECH: JF PROJECT NUMBER: 100018397 CONFIDENTIAL/PROPRIETARTY SHEET 5 OF 12 www.invarion.com uuave FIBER DESIGN & CONSTRUCTION CONTACTS: Justin Fisler CONSTRUCTION MANAGER: JUSTIN FISLER WAVE-FDC 425.457.2306 JFISLER@WAVEBROADBAND.COM PERMIT TECH: JUSTIN FISLER WAVE-FDC 425.457.2306 JFISLER@WAVEBROADBAND.COM SITE ADDRESS: 9TH AVE S LEGEND: Approx Right of Way - - - Approx Center Line Survey Monument Existing Aerial Over Lash New Strand New Fiber Existing Wave Underground Existing Customer Conduit New Wave Conduit New Wave Anchor p Existing Wave Vault O New Wave Vault C� Customer Vault ® Bore Pit O Distribution Poles (:) Transmission Poles ® New Wave Pole N D<0 New Aerial Storage LOCATION: Edmonds PERMIT TECH: JF - PROJECT NUMBER: 100018397 CONFIDENTIAL/PROPRIETARTY SHEET 6 OF 12 www.invarion.com WAVE TO ATTACH 6" BELOW CATV WAVE TO TRANSFER OFF TOPPED PUD POLE AND ONTO NEW POLE. cive FIBER DESIGN & CONSTRUCTION CONTACTS: Justin Fisler CONSTRUCTION MANAGER: JUSTIN FISLER WAVE-FDC 425.457.2306 JFISLER@ WAVEBROADBAN D.COM PERMIT TECH: JUSTIN FISLER WAVE-FDC 425.457.2306 JFISLER@WAVEBROADBAND.COM SITE ADDRESS: SITH AVE S LEGEND: Approx Right of Way - - - Approx Center Line Survey Monument Existing Aerial Over Lash New Strand New Fiber Existing Wave Underground - Existing Customer Conduit New Wave Conduit New Wave Anchor 0 Existing Wave Vault O New Wave Vault C� Customer Vault ® Bore Pit O Distribution Poles ® Transmission Poles 0 New Wave Pole C>4 New Aerial Storage LOCATION: Edmonds PERMIT TECH: JF PROJECT NUMBER: 100018397 CON FIDENTIAL/PROPRIETARTY SHEET 7 OF 12 molUmmunim -0 www.invarion.com WAVE TO TRANSFER OFF TOPPED PUD POLE AND ONTO NEW POLE. FIBER DESIGN & CONSTRUCTION CONTACTS: Justin Fisler CONSTRUCTION MANAGER: JUSTIN FISLER WAVE-FDC 425.457.2306 JFISLER@WAVEBROADBAND.COM PERMIT TECH: JUSTIN FISLER WAVE-FDC 425.457.2306 JFISLER@WAVEBROADBAND.COM SITE ADDRESS: 70TH AVE W LEGEND: Approx Right of Way - - - Approx Center Line o Survey Monument Existing Aerial Over Lash - New Strand New Fiber Existing Wave Underground Existing Customer Conduit New Wave Conduit New Wave Anchor IE] Existing Wave Vault © New Wave Vault © Customer Vault ® Bore Pit O Distribution Poles Q Transmission Poles • New Wave Pole D4 New Aerial Storage LOCATION: Edmonds PERMIT TECH: JF PROJECT NUMBER: 100018397 CONFIDENTIAL/PROPRIETARTY SHEET 10 OF 12 www.invarion.com 4 TO ATTACH 40" BELOW NEUTRAL rfolk _l7_1►`MyCON 'A119112I4710S 4 (3ve FIBER DESIGN & CONSTRUCTION CONTACTS: Justin Fisler CONSTRUCTION MANAGER: JUSTIN FISLER WAVE-FDC 425.457.2306 JFISLER@WAVEBROADBAND.COM PERMIT TECH: JUSTIN FISLER WAVE-FDC 425.457.2306 JFISLER@WAVEBROADBAND.COM 1 SITE ADDRESS: 106TH AVE W & 229TH PL SW LEGEND: Approx Right of Way - - - Approx Center Line Survey Monument Existing Aerial Over Lash New Strand New Fiber Existing Wave Underground Existing Customer Conduit New Wave Conduit New Wave Anchor O Existing Wave Vault O New Wave Vault E=1 Customer Vault Bore Pit 0 Distribution Poles 0 Transmission Poles 40 New Wave Pole c>0 New Aerial Storage LOCATION: Edmonds PERMIT TECH: JF PROJECT NUMBER: 100018397 CONFIDENTIAL/PROPRIETARTY SHEET 11 OF 12 www.lnvarion.com El WAVE TO TRANSFER OFF TOPPED PUD POLE AND ONTO NEW POLE. ciL)e FIBER DESIGN & CONSTRUCTION CONTACTS: Justin Fisler CONSTRUCTION MANAGER: JUSTIN FISLER WAVE-FDC 425.457.2306 JFISLER@ WAVEBROADBAN D.COM PERMIT TECH: JUSTIN FISLER WAVE-FDC 425.457.2306 JFISLER@WAVEBROADBAND.COM SITE ADDRESS: 106TH AVE W & 229TH PL SW LEGEND: Approx Right of Way - - - Approx Center Line �>) Survey Monument Existing Aerial Over Lash New Strand New Fiber Existing Wave Underground Existing Customer Conduit New Wave Conduit New Wave Anchor O Existing Wave Vault C� New Wave Vault 0 Customer Vault ® Bore Pit 0 Distribution Poles (� Transmission Poles ® New Wave Pole c-0 New Aerial Storage LOCATION: Edmonds PERMIT TECH: JF PROJECT NUMBER: 100018397 CON FIDENTIAL/PROPRIETARTY SHEET 12 OF 12