Scope and Spec Sheets.pdfWIZ -1 y:1114-1 FAW�13�dlj;Mr� 4/19/2017 Edmonds, City of 121 5th Avenue N Edmonds, WA 98020 Seattle - Tacoma - Poulsbo - Bellingham Guardian Security Systems would like to install 1 AES Radio to monitor the existing FACP. Northwest Alarm Central Station located at 1743 1St Ave S., Seattle, WA 98134 will be monitoring the following address: Pacific Medical Plaza 21727 76th Ave West Edmonds, WA 98026 Sincerely, Sheramie Odell Permits Specialist/Admin Assistant 360.647.0110 ext. 327 Enclosure 1501 Kentucky ST Bellingham, WA 98229 Tel: 360.647.0110 Fax: 360.715.9008 A ; WT/7� 7 8 RF Subscriber Unit UL Fire, AA Burglary and N'FPA-72 Compliant UL Listed UL Listed Central Station Remote Station 864 Ed. 9, 827, 1610, 365, 681 CSFM NFPA RF Section 8.6.3.5 Advanced Wireless Alarm Monitoring The 7744/7788 smart subscriber unit links an alarm panel to an alarm monitoring central station. This 2 -way transceiver and repeater in one is housed in a full size locking steel cabinet for superior performance. The 7744/7788 supports a wide range of inputs such as NO/NC/EOL and direct voltage. It automatically senses wire and antenna cuts, and monitors battery and AC power status. Advanced status reporting, self -diagnostics and a built-in power supply make the 7744/7788 the first choice for all wireless alarm communication needs. Full Data for Fire and Burglary Use with the optional Firetap for full fire data or the IntelliTap for full fire and burglary data. 7744— 4 reversing polarity inputs plus 4 programmable EOL inputs 7788 — Programmable EOL inputs with 8 zones FireTap 7770 IntelliTap 7067 NEMA 4 Enclosure High Gain Antenna Additional Back Up Battery Available in Burglary Beige or Fire Red RECEIVED APR 2 01 20117 DEVELOPMENT■ ' 1 COUNTER &ES " F RECEIVED APR 2 0 2017 DEVELOPMENT SERVICES • Optionsorull Data for Fire and Burglary • Available in 7744 & 7788 Zone Configurations • Built-in Power Supply and Battery Charger 9�m 'TO FIELD RF Subscriber Unit Technical Specifications Radio Standard CSAA frequency ranges: 450-470 MHz and 1'30-174 MHz, VHF and UHF. Others available Standard Output Power 2 watts (requires FCC license) Power Input 16.5 VAC, 40VA UL listed Class II transformer required Voltage 12 VDC nominal Current 175mA standby; 800mA transmit Alarm Signal Inputs • 4 individually programmable Zones: NO/NC/EOL, trouble restore • RS -232 • Reversing voltage (7744 only) 12 or 24 VDC Operating Temperature Range 0° to 50°C, 32° to 122°F Storage Temperature Range -10° to 60°C, 14° to 140°F Relative Humidity Range 0-85% RHC non -condensing Back up Battery 12V, 7 AH Low Battery Reporting 22.5 -minute test cycle AC Status Reports to central station after approximately 60 minutes without AC power, reports power restored after approximately 60 minutes of restored power. programmable from 60 to 180 minutes Antenna Cut (local reporting) Form 'C' Contact 1 AMP Size 13.25"H x 8.5"W x 4.3"D 34cm x 21.5cm x 11 cm Weight 6.4 lbs, 2.9 Kilograms (excluding battery) Colors Available in standard Burglary Beige or Fire Red Please specify when ordering Available Options • 7788 RF subscriber unit with 8 EOL inputs • 7744 RF subscriber unit with 4 EOL inputs and 4 reverse polarity inputs • 7770 - FireTap • 7067 - IntelliTap • NEMA 4 Enclosure Please specify when ordering AES-IntelliNet is the industry leader in delivering high quality wireless mesh networks to the fire and security industry in commercial, corporate, government, and educational applications with its broad line of products and advanced network management tools. Users ofAES-IntelliNet networks have gained significant rev- enue, communications, and cost advantages while meeting the high standards of reliability required for the fire and security industry, AES-IntelliNet alarm monitoring systems are deployed at hundreds of thousands of locations in over 130 countries. .4AMOF NWAES IntelfiNet CORPORATION For Alarm Monitoring For more information Call 800 -AES -NETS (800-237-6387) AES Corporation 1 285 Newbury Street I Peabody, MA 01960 USA Tel. +1 978-535-7310 1 Fax +1 978-535-7313 1 Email info@aes-intellinet.com Web www.aes-intellinet.com Available configurations • 7788, 8 EOL inputs • 7744; 4 EOL inputs w/4 reverse polarity inputs Overview Intell"I'Pro ES�lntelfiNet Fird' (',0f r1011A"r10N 1'Csr'A1rmr7r 1�ani rrr9r�r� t Easy Installation IntelliPro Fire easily installs in the subscriber housing and is powered from the transceiver module, requiring no additional power connections. AES sub- scribers can be ordered with IntelliPro Fire installed. IntelliPro Fire is easy to program using the AES Handheld Programmer. Features • Commercial fire alarm applications - with or without phone lines • Transmits full alarm data from any Contact ID or Pulse format fire alarm panel • Supports expanded event reporting from Bosch Modem II and Modem III alarm panels • Universal wireless alarm transmitter - works with most manufacturers' panels • Easy to install in AES subscriber • Easily programs using an AES Handheld Programmer • Option to monitor telephone lines 'The AES -7794 IntelliPro Fire converts Modem Ile and Modem IIla2 codes to Contact ID for transmis- sion over the IntelliNet network and supports those alarm panels listed in the table located at www.aes-intellinet.com/AES-InteII!Net-70941ntelIiPro.htm1. This table will be updated as additional panels are tested. AES Corporation 1285 Newbury Street I Peabody, MA 01960 USA Call 800 -AES -NETS (800-237-6387) or +1 978-535-7310 i Fax +1 978-535-7313 i Email info@aes-intellinet.com Web www.aes-intellinet.com Technical Specifications • Transmits full data to AES receiver using Contact ID or Pulse formats • Formats Supported: Contact ID, Pulse 3+1, Pulse 4+1, Pulse 4+2, Modem Ile', and Modem IIla2' 1/0 Connections • AES subscriber with power • Handheld/PC programming port • POTS incoming phone line • Phone output from alarm panel • Trouble output (form C relay) Size • 2.8 x 5.0 inches (7.1cm x 12.7cm) Power Requirements - 12 VDC nominal, primary and backup power provided by the AES RF Transceiver Unit How to Order Model D W601io 7794 IntelliPro Fire 7744F-ULP UL Fire Subscriber w/7794 °(4 reversing polarity &;4 EOL inputs) 7788F-ULP UL Fire Subscriber "w/77PA NOTICE OF SMALL WORKS PROJECT PAGE 1 OF 1 NOTICE OF � SMALL WORKS PROJECT The Port of Anacortes will be soliciting bids to our current Small 'Works Roster applicants for the followingproject: PROJECT NAME: 2017 PORTWIDE SECURITY CAMERA SYSTEM UPGRADE PROJECT NUMBER: GEN-14 The project generally involves removal and salvage of existing cameras and Wi-Fi equipment and procurement and installation of new cameras and Wi-Fi equipment and associated supporting electrical infrastructure at Port of Anacortes Pier 2 Marine Terminal, Anacortes Airport, and Cap Sante Marina in Anacortes, WA. SCOPE OF WORK: y r ANACORTES AIRPORT CAP SANTE MARINA PIER 2 MARINE TERMINAL ENGINEER'S ESTIMATE: $32,500 A complete set of Contract Documents will be transmitted electronically to interested bidders. Please email your request to CONTRACT DOCUMENTS: jenlcins ortofanacortes,com A rebid meeting is scheduled as follows: Date: Friday, April 28, 2017 Time: 10:00 AM PRE-BID MEETING: Location: Port of Anacortes — Main Port Office 100 Commercial Avenue Anacortes, WA Attendance is strongly encouraged. BIDS DUE: 10:00 AM Friday — May 5, 2017 PROJECT SCHEDULE: Substantial completion by June 30, 2017 Please disregard this notice If your ,are not Interested In bidding this project or If you received this notice In error. your application will remain on file for future work throughout the remaining terns of our current Small Works Roster. Thant: You. NOTICE OF SMALL WORKS PROJECT PAGE 1 OF 1 PrJ AGM Real Estate Warren Building 2100 124th Avenue NE Suite 100 21727 26th Avenue West Bellevue, WA 98005 Edmonds, WA 98026 Client Plan 2DFLOORPLANS,COM Floor ISI 1 H wD 206-32&7410 p .M"r�' p%P7dP' V 60a NW GO.- BW SuOe e 1"quxh, WA 90027 Floor Scale Measured: July 2015 Project: CIS -751