seismic-ACM7-clip-submittal-AC3269.pdf Donn Suspension Systems Submittal Sheet ® ACM7 Seismic Clip Description The D ACM7 seismic clip is designed to provide the most robust hold in the most stringent ONN seismic design categories. ACM7 Seismic Clip – Meets or exceeds all national code requirements with 7/8 wall molding – Offers an aesthetically attractive option to traditional 2 angle molding – Provides evidence of compliance (and greatly exceed) ICC Evaluation Service, Inc. (ICC-ES) AC156 and AC368 requirements – Provides support on either side of the web and around the bulb of the tee – Laboratory-tested to greatly exceed all structural and seismic requirements including tension, compression and tee fallout – Slot allows 3/4 movement in both directions – The clip adjusts easily to accommodate tees that intersect the wall at an angle other than 90 degrees – No special fasteners required Applications – All interior general use areas – All main D suspension systems, DX/DXL, F (DXF), F 1/8 (DXFF), DXI I (DXI), ®™®®™™ ONNINELINEINELINEDENTITEE C (DXT), CE (Controlled Environment), DXW, DXLA, and ZXLA (Environmental), include the ™™™ ENTRICITEE code-compliant intermediate-duty and heavy-duty main tees for Seismic Design Categories C, D, E and F. Construction ACM7 Clip, Tight Wall ACM7 Clip, Floating Wall ACM7 seismic clip ACM7 seismic clip 7/" x 7/" wall molding 7/" x 7/" wall molding 88 tee 88 tee 7/" 7/" 8 8 Item Number Seismic Zone/Design Category D Seismic Solutions Seismic Clip Performance Performance ONN UBC IBC Categories D,E,F Alternate Method ACM7 0-4 A-F Min. 7/8 Molding with ACM7 Tension >500 load (lbs.) Seismic Clip Compression > 300 load (lbs.) The D ACM7 seismic clip is designed to provide a more robust hold than traditional L-shaped seismic clips by other manufacturers. ONN ACM7 Seismic Clip spaces. The slot in the clip measures 1.812 to allow 3/4 movement in both directions, accommodate the fastener dimension and allow for slight off center installation of the fastener without impeding performance. The clip adjusts easily to accommodate tees that intersect the wall at an angle other than 90 degrees. The ACM7 clip sustained tremendous forces in tension and compression testing, far greater than would be experienced in a seismic event. ACM7 Seismic Clip Performance Test Failure Criteria Result Tension Test Tee fallout/ separation from clip. > 500 load (lbs.). Test stopped at this load, with clip still attached to tee; failure load will exceed this level. Compression Test Tee fallout/ separation from clip. > 300 load (lbs.). Test stopped at this load, with clip still attached to tee maintaining 3/4 clearance from wall; failure load will exceed this level. Submittal Job Name Approvals Contractor Date Physical Data/ MaterialICC Evaluation Service, Inc., Testing of Nonstructural Components evaluated and tested. Results of deemed waived unless made in writ- Footnotes Hot-dipped galvanized steel.Report Compliance and Systems. AC156 was not this investigation indicates that ing to us within thirty (30) days from Suspension systems manufactured these tested alternative designs date it was or reasonably should Recycled Content by USG Interiors, LLC, have been testing guidelines or pass/fail criteria are at least the equivalent of that have been discovered 25%. For details, see the reviewed and are approved by listing for acoustical suspension systems prescribed in the code for quality, Sustainability selector.Note in ICC-ES Evaluation Report 1222. in a seismic event. However, in the The University of Buffalo and Installation Evaluation Reports are subject resistance, durability and safety. the University of California do Must be installed in compliance with to reexamination, revision and purpose, ICC-ES allowed AC156 to These alternative designs are at least ASTM C636, CISCA, and standard possible cancellation. Please act as the basis for all seismic testing equivalent to the criteria set forth in industry practices.Construction Details refer to usgdesignstudio.com or and evaluation for the acoustical AC156 and AC368, and otherwise Please see AC3235 for 800 USG.4YOU for current reports. ceiling suspended ceilings industry. demonstrate compliance with the Limitations construction details. performance features of the codes. The performance of D ACM7 ONN L.A. Research Report Code Compliance The data and test results presented seismic clip and systems is based on Safety First! Compliance Testing and evaluation performed provide technical evidence on which Follow good safety/industrial hygiene D brand suspension systems at the University at Buffalo (SUNY), ONN components, and design and instal-practices during installation. Wear manufactured by USG Interiors, the Department of Civil, Structural lation methods shown. Components appropriate personal protective LLC, have been reviewed and are and Environmental Engineering—Notice from other manufacturers were equipment. Read MSDS and approved by listing in the following Structural Engineering and We shall not be liable for incidental not evaluated, and their use or any L.A. Research Report number: Earthquake Simulation Laboratory and consequential damages, directly mixed use is not recommended. installation. 25764. (SEESL) qualify the performance or indirectly sustained, nor for any of these systems according to the loss caused by application of these AC156 Disclaimer goods not in accordance with cur- The current ICC-ES acceptance rent printed instructions or for other criterion (AC) used for the testing Acceptance Criteria for Suspended than the intended use. Our liability is and evaluation of seismic clips is Ceiling Framing Systems. Several expressly limited to replacement of AC156, Acceptance Criteria for alternative materials, designs and defective goods. Any claim shall be methods of construction were Manufactured byusg.comThe following are trademarks of USG AC3269/rev.8-13 USG Interiors, LLCseismicceilings.comInteriors, LLC, or a related company: AX, © 2013, USG Interiors, LLC 550 West Adams Streetsustainableceilings.com C, C R, D, DX, DXI, Printed in U.S.A. ENTRICITEELEANOOMONN Chicago, IL 60661usgdesignstudio.comDXL,DXLA, DXW, F, I, USG, INELINEDENTITEE USG in stylized letters and ZXLA.