SKMBT_C45008060216260.pdfILA I DILTS [elm, VI 111105 June 2, 2008 TO: Megunli Matsumura, CDA Architects FROM: Steve Fisher, City of Edmonds Public Works, 425-771-02315 R -E: Plan review for proposed trash enclosure #2008-0319 Nordic Ventures, 310 5t" Ave. S The proposed location of a trash enclosure/room at the southwest comer adjacent to the real- alleyway is appropriate. However, the servicing and use of this area requires there be no slope exceeding 2 % from alley grade to the enclosure floor. The elevations are unclear what the true grade relationship is at this point. The elevation also indicates a rather short finished height for the trash room. The minimum height of a collection area within a building is 8 foot, exclusive of lighting, sprinklers, etc. The elevation suggests the height is less than 6 foot. While the footprint size of the trash room is appropriate, the entrance gates/doorways need to be able to open across the whole width of the room (indicated as approximately 16' on the plan), making the entire room accessible and providing the ability to maneuver the larger wheeled containers. Please call me for any clarifications or resubmit trash room details based on these comments.