Loading...
SKMBT_C45008080416250.pdfAugust 4, 2008 TO: Warren LaFon FROM: Steve Fisher, City of Edmonds Public Works, 425-771-0235 RE: Plan review for proposed trash enclosure #2008-0287 Jantz Building, 547 Dayton St. Please address the details asked for in my Trash Enclosure comments 1, dated May 14, 2008 and reiterated by the Engineering Plan Review comments dated July 24, 2008. The location of the gate supports need to be indicated to show the minimum 10' clearance when gates are fully opened. Please indicate that the gate swing has the ability to swing toward a full 180 degrees. Appropriate hardware, such as drop pins/pavement sleeves are required for proper positioning of gates when open and closed. Securing devices need to be indicated on the enclosure detail required under the general design standards. Please indicate on the appropriate elevation, the finished inside height of the trash area (minimum height of 8'exclusive of lighting, sprinklers, etc.), plus the material used for the gate sections.